My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011819
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
11241
>
2600 - Land Use Program
>
PA-1600266
>
SU0011819
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:28 AM
Creation date
9/9/2019 10:35:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011819
PE
2625
FACILITY_NAME
PA-1600266
STREET_NUMBER
11241
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95219-
APN
05520003
ENTERED_DATE
6/14/2018 12:00:00 AM
SITE_LOCATION
11241 N THORNTON RD
RECEIVED_DATE
6/14/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\11241\PA-1600266\SU0011819\APPL.PDF \MIGRATIONS\T\THORNTON\11241\PA-1600266\SU0011819\CDD OK.PDF \MIGRATIONS\T\THORNTON\11241\PA-1600266\SU0011819\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Inspection Division: <br /> 1) A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with The 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2) A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional.The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code.The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3) The required plans must be complete at the time of submittal for a building permit. Plans <br /> must address building design and construction, fire and life safety requirements, accessibility <br /> and show compliance with the-current California codes and San Joaquin County ordinances. <br /> A complete set of plans must include fire sprinkler plans,truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br /> and energy report. <br /> 4) For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> J. Occupant load based on the CBC <br /> K. Occupant load based on the CPC <br /> 5) Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11 B-206.2.1 <br /> 6) At least one accessible route shall connect accessible buildings, accessible facilities,accessible <br /> elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 7) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project.These parking space(s)shall be located as close as possible to <br /> the primary entrance to the building. <br /> PA-1600266 Conditions of Approval <br />
The URL can be used to link to this page
Your browser does not support the video tag.