My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002185
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
2600 - Land Use Program
>
UP-00-24
>
SU0002185
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2019 8:43:18 AM
Creation date
9/9/2019 10:58:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0002185
PE
2626
FACILITY_NAME
UP-00-24
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
STREET_TYPE
RD
City
TRACY
ENTERED_DATE
10/23/2001 12:00:00 AM
SITE_LOCATION
17950 W VIA NICOLO RD
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\V\VIA NICOLO\17950\UP-00-24\SU0002185\MISC.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ON <br /> Septic System Expansion - r n Page No.2 <br /> Musco Family Olive Co. <br /> June 13,2003 <br /> Summary of Leach Line Elevation Differences Between Beginning and End <br /> 2"d Leach Field(New) <br /> No.Leach line 1 2 3 4 5 6 7 8 <br /> Elevation Diff. (in.) 5.4 16.8 15.0 9.6 14.4" 25.8 22.2 15.8 <br /> 3`d Leach Field (New) <br /> No. Leach line 1 2:j 3 4 5 6 7 8 <br /> Elevation Diff.(in.) 12.6 11.4 9 9 10.2 12.6 12 6.6 <br /> These,elevation differences are of the leach line piping as currently laid. A return visit was made <br /> to spot check the elevation difference of the bottom of the leach trench. This was accomplished <br /> by probing through the gravel until encountering the subgrade soil. It was found that the trench <br /> bottoms also sloped,but it was slightly less then the piping slope. <br /> It is concluded that as long as the elevation difference of an individual leach line is 7,inches or <br /> less, then no corrective measure is necessary for the trench bottom. However,if the elevation <br /> difference is greater then 7 inches then the installation of a"soil dike" and additional pipe <br /> penetrations are necessary to help retain effluent in the upper portions of the trench. Soil dikes <br /> and pipe penetrations should be installed as shown on the attached"As-Built' drawing. In <br /> addition, the end of each leach line piping should be elevated 4 inches to create a"sag"in the <br /> leach line so that effluent can exit it before reaching the dry well. <br /> Item 2 <br /> The invert elevations of the exiting pipes of the distribution boxes were checked and found to <br /> vary as much as 1 inch. The distribution boxes should be re-leveled to maintain an invert <br /> elevation difference no greater then 0.25 inch. The distribution boxes contain cracks and require <br /> a mastic seal placed within each distribution box. <br /> Item 3 <br /> The baffle in the 5' septic tank should be "bricked"closed and the pipe penetration and elbow <br /> should be installed as indicated on Detail Plan for Septic System, Plate 1D, revised May 13, <br /> 2003. <br /> 9ER2 <br /> 1 <br /> f` <br /> ��SO�E <br />