SU0004353 ENG DES PLN
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
26485
>
2600 - Land Use Program
>
PA-0200247
>
SU0004353 ENG DES PLN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:41 AM
Creation date
9/17/2019 10:42:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
ENG DES PLN
RECORD_ID
SU0004353
PE
2632
FACILITY_NAME
PA-0200247
STREET_NUMBER
26485
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
THORNTON
ENTERED_DATE
5/17/2004 12:00:00 AM
SITE_LOCATION
26485 N THORNTON RD
RECEIVED_DATE
6/13/2002 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\26485\PA-0200247\SU0004353\ENG DES PLN.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Septic System Design Page 2 <br /> • A filter bed 30 by 45 feet will be provided for each unit. One hundred percent <br /> reserve area will be provided on the site plan. <br /> • Quarterly sampling and system inspection is recommended. <br /> System Design Criteria <br /> • Two MicroSeptec EnviroServer#ENFGI500 will be required to provide a design <br /> sewerage flow of 3000 gallons per day. <br /> • A filter bed size of 2700 square feet was determined by an engineering evaluation <br /> of the soil type and an on site permeability test. Each filter bed will serve one of <br /> the MicroSeptec units. The filter bed size will be 30 by 45 feet. <br /> • Drain from the food preparation area must flow to the grease trap prior to the <br /> sewer treatment units. A dosing point is required in the second chamber of the <br /> grease trap to be equipped with float switches to activate the pump and provide a <br /> high level alarm as an indicator of pump failure. <br /> • All pressurized lines leading to the MicroSeptec treatment units must be a <br /> minimum of 2 inches in diameter. All gravity drain lines must be a minimum of 4 <br /> inch diameter. Effluent lines from the MicroSeptec treatment unit to the filter bed <br /> must be 1 and one half inch diameter minimum. <br />
The URL can be used to link to this page
Your browser does not support the video tag.