Laserfiche WebLink
Seismic/Anchoring: <br /> Tank anchorage is specifically designed for crosslinked polyethylene tanks, and <br /> consists of metal clips bolted to the concrete foundation pad,with cables running <br /> between the clip and a tension ring on the top of the tank. These are designed by a <br /> civil/structural engineering firm, and are purchased from the tank manufacturer, <br /> Poly Processing Co. The system for the wastewater storage tank and caustic tank <br /> are shown in the attached signed and stamped drawings. <br /> Seismic/Anchoring findings: The tanks as designed and operated, and the containment <br /> areas in which th y are located, are adequately anchored and are seismically sound. <br /> Initials�kiX <br /> Leak Test: <br /> A leak test was conducted by filling the tanks with process fluid(wastewater or <br /> caustic)and inspecting for leaks. There were no signs of leakage. <br /> Tank Integrity: Based on the fact that the tanks have contained wastewater and caustic <br /> for several years without signs of leakage,the tanks have sufficient integrity for their <br /> intended use. <br /> InitialYr.AX <br /> Tank Dr 'ng: <br /> (.�/1US�d ki �as � Yvaf�r <br /> CaushC <br /> t <br /> . <br /> Facing - - - <br /> OE S W <br /> Tank Diameters: 12 feet, 10 feet and 8 feet. <br /> Tank Height: 14 ft 2 in., 10 ft 3 1/2 in., and 8 ft 9 ins. overall <br /> Tank Gross Capacity: 10,300 gallons wastewater and 3000 gallons caustic. <br /> California Tank Lines, Inc. Wastewater Storage Tank and Caustic Tank <br />