My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0516806
>
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 8:41:30 AM
Creation date
9/25/2019 4:52:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LEC APPLICATION FOR CERTIFICATION
RECORD_ID
PR0516806
PE
2965
FACILITY_ID
FA0012817
FACILITY_NAME
WHITE SLOUGH WATER POLLUTION CONTRO
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95241
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WorleyParsons <br /> resources&energy <br /> Site Class C <br /> Seismic Design Category is assigned to each <br /> Seismic Design Category(Table 1613.5(1)and structure based on its Occupancy Category and <br /> (2)) the severity of the design earthquake ground <br /> motion at the site. <br /> Spectral Response Acceleration SDs(Table <br /> 1613.5(1)and(2)) 0.5 <br /> Response Modification Factor, R(ASCE 7-05, 2.5 <br /> Table 13.6-1) <br /> Seismic Importance Factor, 1 1.25 <br /> 1.5 Air Emission Limitations <br /> The plant design is based on being able to meet the proposed emission limits for <br /> the CTG/SCR as provided in the Air Quality section of the Application for <br /> Certification. <br /> 1.6 Fuel Gas <br /> Pipeline-quality natural gas will be provided by PG&E, with site-specific tie in <br /> points to be determined. The gas piping from the gas utility interconnection point <br /> to the generating equipment will be part of power plant design and construction <br /> scope. <br /> 1.7 Water Supply <br /> 1.7.1 Raw Water Supply <br /> Raw water for each site will be "Title 22" water obtained from the City of Lodi <br /> White Slough Water Pollution Control Facility (WPCF) located adjacent to the <br /> power plant. <br /> 1.7.2 Plant Wastewater <br /> Facility waste water streams from the water treatment, the oily water separator, <br /> evaporative cooler, HRSG drum blow downs make are transferred to the cooling <br /> tower. Cooling tower blow down is then injected into the injection well. <br /> 1.7.3 Stormwater Runoff <br /> By design the storm water will be sent to the WPCF via various sump pumping <br /> stations through out the facility. <br /> Lodi Energy Center 3.1 -5 LEC AFC <br /> 071708 Rev.A <br />
The URL can be used to link to this page
Your browser does not support the video tag.