My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0516806
>
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 8:41:30 AM
Creation date
9/25/2019 4:52:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LEC APPLICATION FOR CERTIFICATION
RECORD_ID
PR0516806
PE
2965
FACILITY_ID
FA0012817
FACILITY_NAME
WHITE SLOUGH WATER POLLUTION CONTRO
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95241
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 3.0:ELECTRIC TRANSMISSION <br /> 3.5.4 Communications Interference <br /> The LORS pertaining to communication interference are listed in Table 3.5-4. <br /> TABLE 3.5-4 <br /> Communications Interference LORS <br /> LORS Applicability <br /> 47 CFR 15.25, "Operating Requirements, Prohibits operations of any device emitting incidental radiation that <br /> Incidental Radiation" causes interference to communications; the regulation also <br /> requires mitigation for any device that causes interference. <br /> GO-52, CPUC Covers all aspects of the construction, operation, and maintenance <br /> of power and communication lines and specifically applies to the <br /> prevention or mitigation of inductive interference. <br /> CEC staff, Radio Interference and Television Prescribes the CEC's RI-TVI mitigation requirements, developed <br /> Interference(RI-TVI)Criteria (Kern River and adopted by the CEC in past citing cases. <br /> Cogeneration)Project 82-AFC-2, Final <br /> Decision, Compliance Plan 13-7 <br /> 3.5.5 Aviation Safety <br /> Table 3.5-5 lists the aviation safety LORS that may apply to the proposed transmission <br /> interconnection and the overall project. LORS for the overall project are discussed in the <br /> appropriate sections of this AFC. <br /> TABLE 3.5-5 <br /> Aviation Safety LORS <br /> LORS Applicability <br /> Title 14 CFR, Part 77, "Objects Affecting Describes the criteria used to determine whether a"Notice of <br /> Navigable Airspace" Proposed Construction or Alteration"(NPCA, FAA Form 7450-1) is <br /> required for potential obstruction hazards. <br /> FAA Advisory Circular No. 70/7450-1G, Describes the FAA standards for marking and lighting of <br /> "Obstruction Marking and Lighting" obstructions as identified by FAA Regulations Part 77. <br /> CPUC, Sections 21555-21550 Discusses the permit requirements for construction of possible <br /> obstructions in the vicinity of aircraft landing areas, in navigable <br /> airspace, and near the boundary of airports. <br /> Title 21, CCR, Sections 3525 through 3560 Discusses the permit requirements for construction of possible <br /> Airports and Heliports obstructions in the vicinity of aircraft landing areas, in navigable <br /> airspace, and near the boundary of airports. <br /> 3.5.6 Fire Hazards <br /> Table 3.5-6 lists the LORS governing fire hazard protection for the proposed transmission <br /> interconnection and the overall project. LORS for the overall project will be discussed in the <br /> appropriate sections of this AFC. <br /> 3-12 SAC/371322/082350006(LEC_3.0_ELECTRANS.DOC) <br />
The URL can be used to link to this page
Your browser does not support the video tag.