My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
12751
>
2900 - Site Mitigation Program
>
PR0516806
>
ARCHIVED REPORTS LEC APPLICATION FOR CERTIFICATION
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 8:41:30 AM
Creation date
9/25/2019 4:52:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
LEC APPLICATION FOR CERTIFICATION
RECORD_ID
PR0516806
PE
2965
FACILITY_ID
FA0012817
FACILITY_NAME
WHITE SLOUGH WATER POLLUTION CONTRO
STREET_NUMBER
12751
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95241
APN
05513016
CURRENT_STATUS
01
SITE_LOCATION
12751 N THORNTON RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® WorleyParsons <br /> resources&energy <br /> 3.5.1 General <br /> NFPA 850 and the applicable fire code will provide the general guidance for the fire <br /> protection considerations of the facility. A Fire Mitigation Design Plan will be prepared <br /> to detail the site-specific fire protection features of the facility. <br /> The fire prevention and protection design for the facility will be reviewed and must <br /> receive approval from the local Fire Marshal and Owner's insurance representative. <br /> Automatic and manual fire protection systems employing detection and extinguishing <br /> equipment will be provided at all locations having potential fire hazard due to the <br /> presence of combustible materials or where major property damage could result. Yard <br /> hydrants and portable extinguishers will provide additional incipient fire extinguishing <br /> capability and overall protection throughout the plant site. <br /> The fire protection water supply will be taken from an onsite fire/raw water storage tank <br /> and distributed to the site fire protection system via a new underground firewater loop <br /> with necessary hydrants. The fire loop will be pressurized by an electric motor driven <br /> fire pump with a diesel driven fire pump as a backup. Hose houses will not be installed <br /> around the yard since plant-operating personnel will only be trained to extinguish <br /> incipient fires and local fire department personnel will only use their own hose. <br /> 3.5.2 Fire Protection System <br /> It is expected that the new plant fire protection system will be physically tied into the <br /> existing plant's underground firewater piping loop. The advantage to this design is <br /> obvious in that the entire site can take advantage of a single set (existing) of fire pumps. <br /> As a minimum, the fire protection system will include: <br /> Area of Building Standard Detail <br /> Use Dry Chemical only if it is <br /> best option <br /> Fire Extinguishers Site Wide NFPA 10 Wheeled 33 gallon AFFF and <br /> 50 pound dry chemical <br /> extinguishers in the fuel oil <br /> pump, storage, and heating <br /> areas. <br /> Fire Hose & Standpipe NFPA 14 Provide for the Warehouse <br /> Lodi Energy Center 3.3 -6 LEC AFC <br /> 071508 Rev.A <br />
The URL can be used to link to this page
Your browser does not support the video tag.