1 I <br />' Quarterly Report - Fourth Quarter 2005 <br /> . LODI AIRPORT <br />' 23987 North Highway 99, Acampo, California 95220 <br />' 1.0. INTRODUCTION <br /> At the request of Mr Robert Kupka of Lodi Airport,Advanced GeoEnvironmental, Inc (AGE)has <br />' prepared this quarterly report for the property located at 23987 North Highway 99, Acampo, <br /> California(site) The scope of work included quarterly ground water monitoring and preparation of <br /> this report The location of the site and the immediately surrounding area are illustrated on Figure <br />' 1, structures, former UST locations, monitoring well and soil boring locations are illustrated on <br /> Figure 2 Background information is included as Appendix A <br />' 2.0. E J <br /> PROC DURES <br />' Field work was performed in accordance with guidelines established by the California Regional <br /> Water Quality Control Board-Central Valley Region for investigation of underground storage tank <br /> (UST) sites <br /> 21 QUARTERLY WELL MONITORING PROCEDURES <br /> The fourth quarterly ground water monitoring event was performed on 02 December 2005, ground <br /> water monitoring was performed on monitoring wells MW-1 through MW-3 Additionally,the on- <br /> site domestic well was sampled <br /> Well onitoring and Evacuation <br />' On 02 December 2005, a Solinst water level meter was used to measure the depth to ground water <br /> in all three monitoring wells relative to the tops of the well casings After the depth-to-ground water <br /> measurements were collected, casing water in the monitoring wells was evacuated using polyvinyl <br />' chloride (PVC) disposable bailers Approximately 2 to 2 25 gallons of water were evacuated from <br /> each of the monitoring wells, equivalent to three casing-water volumes per well , <br />' Temperature, pH and conductivity were measured at 1-gallon intervals, using an Oakton water <br /> analyzer to monitor pH, temperature and conductivity of the purged water, the field data logs are <br />' provided in Appendix B Purged water was temporarily stored on-site in 55-gallon drums <br />' 2 12 Collection and Analysis of Ground Water Samples <br /> • Water samples were collected from each monitoring well using new disposable bailers after allowing <br />' Advanced GeoEnvirondnental,Inc <br /> I I i <br />