NO. REV . & DATE <br /> 0. cn <br /> N <br /> ELECTRICAL NOTES : o s <br /> 0 <br /> 1 . ALL WIRING SHALL BE 3 - 12GA THWN CU — W/ 1 / 2 " EMT OR MC vF8 <br /> CABLE UNLESS OTHERWISE NOTED . o N a <br /> 2 . ALL ELECTRICAL WIRING AND BONDING SHALL MEET C . E . C . 2016 v o <br /> 3 . ALL RECEPTACLES SHALL BE NO LESS THAN + 15 "A . F . F . TO BOTTOM TA Ra <br /> 111am �, � <br /> OF BOX , UNLESS OTHERWISE NOTED . ALL SWITCHES & CONTROLS Q u) v 8 <br /> SHALL BE MAX . OF 48 " A . F . F . TO TOP OF BOX . <br /> 4 . ALL EQUIPMENT GROUNDING SHALL CONFORM TO ARTICLE 250 OF <br /> 2016 C . E . 0 <br /> 5 . PANEL BOARD CIRCUIT BREAKERS USED AS SWITCHES MUST BE <br /> APPROVED FOR SUCH DUTY AND BE OF THE " SWD " TYPE PER ( E ) ( 4) 310 THWN CU . <br /> SECTION 240 - 83 ( d ) OF THE C . E . C . ( 1 ) # 6 CU . GND . <br /> 6 , PROVIDE PARITY SIZED GREEN GROUND WIRE IN ALL W1 2 CA CD <br /> CONDUITS / BRANCH CIRCUIT HOMERUNS . � E� LU <br /> 7 . ALL CONDUIT PENETRATIONS THROUGH FIRE — RATED WALLS AND 2 ( E) � <br /> FLOORS SHALL BE SEALED TO MAINTAIN FIRE — SEPARATION RATING , t2A DEDICATED FOR KIOSK z <br /> USE 3M FIRE BARRIER FS - 195 WRAP / STRIP AT PVC PIPE 12 V/ <br /> PENETRATION THRU RATED WALLS , OR EQUAL PRODUCTS . 30 J <br /> 8 . DO NOT INSTALL ANY OUTLETS BACK TO BACK IN STUD WALLS . PANEL Q <br /> 9 . DRAWINGS INDICATE THE LOCATION OF DEVICES , FIXTURES AND V <br /> EQUIPMENT AND THE CIRCUIT NUMBER AND PANEL DESIGNATION ( 3 ) # 3 THWN CU . <br /> WHICH SUPPLIES THEM , ELECTRICAL CONTRACTOR SHALL BE ( 1 ) # 8 CU . GND . F— <br /> RESPONSIBLE FOR COMPLETELY CONNECTING ALL ELECTRICAL W/ 1 1 / 2 C . V <br /> DEVICES TO CIRCUITS INDICATED ON THE DRAWINGS . o J <br /> 10 . PROVIDE MIN . OF 24 " HORIZONTAL SEPARATION , IN BETWEEN SUB — PANEL "A " W <br /> ELECTRICAL BOXES LOCATED ON OPPOSITE SIDE OF WALLS PER 60A/ 12OV/ 24OV/ 10 50A / 2POLE <br /> C . B . C . SEC , 709 . 7 MAIN BREAKEREss�oN <br /> 11 , PENETRATION ON EITHER SIDE OF RATED CORRIDOR WALLS SHALL AT PANEL ND <br /> NOT EXCEED 18 " S . IN . PER PENETRATION . <br /> 12 . ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE Na, 55 88 <br /> UNDERWRITERS ' LABORATORIES , INC . SHALL MEET THEIR Exp.B/3092020 <br /> REQUIREMENTS AND SHALL BEAR THEIR LABEL WHEREVER 9 CAIN N� <br /> STANDARDS HAVE BEEN ESTABLISHED LABEL SERVICE IS REGULARLY 1 . VERIFY SHORT CIRCUIT AMPRAGE KAIC RATING WITH ( E ) SERVICE BEFORE INSTALLATION . <br /> FURNISHED BY THAT AGENCY . 2 , VERIFY DISC . SWITCH FOR EQUIP . BEFORE INSTALLATION . ENGINEER: <br /> 13 . ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND MORAD ENGINEERING <br /> ALTHOUGH THE SIZE AND LOCATIONS OF EQUIPMENT ARE SHOWN EDMOND MORAD. P.E. <br /> 615 13TH STREET <br /> TO SCALE WHEREVER POSSIBLE . CONTRACTOR SHALL MAKE USE OF MODESTO, CA 95354 <br /> ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY THIS (209) 530-0570 <br /> INFORMATION AT THE SITE . CONTRACTOR SHALL BE RESPONSIBLE SINGLE LINE DIAGRAM Y N <br /> FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID <br /> INTERFERENCE WITH OTHER TRADES . (l) Q N <br /> 14 . PROVIDE AND INSTALL 1 / 2 " CONDUIT FROM EACH TELEPHONE O W <br /> OUTLET TO ABOVE THE CEILING . VERIFY LOCATION WITH OWNER Y > <br /> PRIOR TO BID , Z Q Q <br /> 15 . PROVIDE MIN . 1 - 20AMP BRANCH CIRCUIT FOR THE KITCHEN C/) <br /> 0 V <br /> COUNTERS AND HAVE NO ADDITIONAL OUTLETS ON SAID BRANCH , JLL Z <br /> 16 . PROVIDE MIN . 1 — 20AMP BRANCH CKT . DEDICATED FOR THE <br /> WASHER , REFRIGERATOR AND HAVE NO ADDITIONAL ADDITIONAL U) <br /> te <br /> OUTLETS ON SAID BRANCH . Ix Lu (L <br /> Q m L O <br /> YW <br /> dam- U) <br /> DATE: 06 - 10 - 19 <br /> DRAWN BY: R . ORTIZ <br /> JOB NO : <br /> SHEET: <br /> AA <br />