Laserfiche WebLink
NO. REV. & DATE <br /> PLUMBING NOTES : PLUMBING FIXTURE SCHEDULE <br /> 1 . DRAWINGS INDICATE DIAGRAMMATICALLY THE ARRANGEMENT OF PRINCIPLE APPARATUS , CL <br /> PIPING AND OTHER MATERIAL . FOLLOW DRAWINGS AS CLOSELY AS POSSIBLE , IN ORDER MARK MAKE & MODEL DESCRIPTION REMARKS E <br /> TO ACHIEVE A NEAT TO ACHIEVE ARRANGEMENT OF PIPING , AND EQUIPMENT WHILE o <br /> STILL OVERCOMING OBSERVATION . FS - 1 ZURN , Z - 1900 FLOOR SINK 12 "x12 " x6 " FLOOR SINK W/ STEEL GRATENNW <br /> 2 . PIPES ( HW , CW , DRAIN ) UNDER LAVATORY FOR THE PHYSICALLY HANDICAPPED SHALL BE F °o <br /> INSULATED . Z oN <br /> 3 . DRAIN , WASTE , AND VENT PIPE SHALL BE ABS SCH 40 . O C <br /> 4 . WATER PIPES SHALL BE SCHEDULE 40 GALVANIZED STEEL ASTM A120 , OR TYPE L x0 � <br /> COPPER , ASTM B88 , PIPE BELOW GRADE SHALL HAVE PROTECTIVE COATING OF NOTE : VERIFY ALL PLUMBING FIXTURE COLORS WITH OWNER , OPTIONAL; PROVIDE EQUAL CAPACITY UNIT. W o � 8 <br /> Q � � <br /> POLYETHYLENE . <br /> 5 , PROVIDE MIN . OF 1 / 4 "/ FT . SLOPE AT ALL WASTE PIPING AT 3 " PIPE AND SMALLER , WATER SUPPLY FIXTURE UNITS <br /> PROVIDE 1 / 8 "/ FOOT SLOPE AT WASTE PIPE 4 " AND LARGER , <br /> 6 . ALL WATER PIPING IS IN BASEMENT SPACE FIXTURE TOTAL NO . OF <br /> 7 , ALL PLUMBING SHALL MEET 2016 C . P . C . MARK DESCRIPTION QUANTITY UNIT FIXTURE <br /> 8 . PRIOR TO COMMENCEMENT OF WORK , THE CONTRACTOR SHALL VERIFY THE EXACT <br /> LOCATION , ELEVATIONS , AND CHARACTERISTICS OF ALL UTILITIES AND PIPING OF WHICH SINK 3 COMP 1 1 . 5 1 . 5 z <br /> IS TO CONNECT AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY <br /> DISCREPANCIES OR PROBLEMS . HW - 1 HAND WASH SINK 1 1 . 0 1 . 0 <br /> 9 , TRAP FOR ALL LAVATORIES AND SINKS SHALL TRAP STRAIGHT BACK TO WALL WITH ALL <br /> REQUIRED OFFSETS WITHIN THE WALL , TOTAL FIXTURE UNITS 2 . 5 0 <br /> 10 . ALL PLUMBING WORK SHALL BE INSTALLED TO AVOID INTERFERENCE WITH ELECTRICAL , z <br /> MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING , PER CPC CHART A - 3 AT 2 . 5 F . U . EQUATES TO 2 . 5 GPM . m <br /> 11 . ALL CLEANOUTS SHALL BE INSTALLED WHERE EASILY ACCESSIBLE . THE CONTRACTOR BASED ON 2016 C . P , C . APPENDIX A , CHART A - 5 ( E ) 3 /4 " WATER BRANCH PIPE IS OK . <br /> SHALL COORDINATE ALL CLEAN — OUT LOCATIONS WITH ALL EQUIPMENT , CABINETS , ETC , <br /> PRIOR TO INSTALLATION . <br /> 12 . ALL VALVES , UNIONS , ETC . TO BE SAME SIZE AS PIPE UNLESS INDICATED OTHERWISE <br /> ON DRAWINGS . <br /> 13 . BEFORE FABRICATION OR INSTALLATION PLUMBING CONTRACTOR SHALL VERIFY EXACT <br /> LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDER <br /> ANOTHER SPECIFICATIONS . EXACT ROUGH — IN LOCATIONS AND REQUIREMENTS SHALL BE MAY EXTEND AS ° / >�<� <br /> COORDINATED WITH WORK OF OTHER CONSULTANTS AND EQUIPMENT VENDORS WASTE OR VENTDRAWIN <br /> Exp 6/30/2020 <br /> 14 . IF MACHINE SAW CUTTING OF SLAB IS REQUIRED FOR PIPING TO BE INSTALLED BELOW CLEANOUT PLUG <br /> FLOOR . VERIFY EXISTING SLAB CONDITION IN FIELD . 9 civ <br /> 15 . ALL PLUMBING FIXTURES AND EQUIPMENT SHALL BE CERTIFIED BY THE STATE ENERGY FOR WALL CONST . <br /> COMMISSION TO COMPLY WITH EFFICIENCY STANDARDS PER SECTION 2 - 5314 (A) OF REF , ARCH . DWGS . ENGINEER: <br /> THE TITLE - 24 REGULATIONS . COUNTERSUNK <br /> MORAD ENGINEERING <br /> EDMOND MORAD . P.E. <br /> 16 , ALL HOT WATER PIPING SHALL BE INSULATED WITH 1 " THICK MANVILLE " MICROLOCK " SCREW 615 13TH STREET <br /> 850 — APT SNAP ON FIBERGLASS INSULATION , C . I . CLEANOUT TEE MODEST - 95354 <br /> (209) 533 0-0570 <br /> 17 . CONTRACTOR SHALL COORDINATE ALL PLUMBING REQUIREMENTS WITH KITCHEN <br /> EQUIPMENT PRIOR TO BID AND VERIFY POINT OF CONNECTION TO UTILITIES PRIOR TO FLOOR LINE Y J O <br /> CONSTRUCTION , U) Q � <br /> 18 . ALL EQUIPMENT SHALL BE LATERALLY SUPPORTED IN ALL DIRECTIONS TO RESIST 20 % POLISHED S . S . <br /> O <br /> OF THE EQUIPMENT OPERATING WEIGHT , ACCESS COVER <br /> 19 . PIPING PASSING THROUGH CONCRETE FLOORS SHALL BE ADEQUATELY PROTECTED z Q Q <br /> AGAINST BREAKAGE PER CPC SEC . 312 . a 1 / 8 BEND AND END J U U <br /> 20 . ALL PRESSURED WATER PIPING BELOW FLOOR SHALL BE TYPE " L " SOFT ANNEALED 4 <br /> ° a ° ° OF LINE CLEANOUT J Q W z <br /> COPPER TUBING WITH NO FITTING BELOW SLAB , <br /> 21 , THE REDUCED PRESSURE BACK FLOW PREVENTER AT MAIN SERVICE IS EXISTING . WASTE LINE j UO <br /> Q 0 <br /> LENGTH TO SUIT CC <br /> W 13. <br /> U <br /> WASTE LINE W L <br /> Y � U) <br /> FLOW DATE: 06 - 10 - 19 <br /> DRAWN BY: R . ORTIZ <br /> JOB NO: <br /> WALL CLEANOUT DETAIL SCALE S"EETA■ 6 <br /> N . T. S . <br />