My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1448
>
2900 - Site Mitigation Program
>
PR0009096
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2019 8:48:09 AM
Creation date
10/9/2019 8:27:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0009096
PE
2960
FACILITY_ID
FA0004082
FACILITY_NAME
U S CHEMICAL COMPANY
STREET_NUMBER
1448
Direction
N
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
14326007
CURRENT_STATUS
02
SITE_LOCATION
1448 N SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM _6_ <br /> USC/A DIVISION OF HYDRITE CHEMICAL COMPANY <br /> CLASS II SURFACE IMPOUNDMENT <br /> SAN JOAQUIN COUNTY <br /> Sampling & Reporting <br /> Report in Parameter/Constituent <br /> Units of Frequency <br /> Flow gallons/day Monthly <br /> LCRS MONITORING <br /> Until the surface impoundment is closed, the LCRS shall be tested annually to <br /> demonstrate operation in conformance with waste discharge requirements. The <br /> results of these tests shall be reported to the Board and shall include <br /> comparison with earlier tests made under comparable conditions. <br /> LINER PERFORMANCE MONITORING <br /> Unless a closure plan is submitted by 1 July 1992, a Liner Performance Monitoring <br /> Plan shall be submitted to Board staff by 1 July 1992. This plan shall be <br /> submitted in conjunction with the Design Plans for retrofitting the impoundment <br /> liner required by Discharge Specification B.10 and Provision C.19 of this Order. <br /> This plan shall include, but not be limited to, the type(s) of equipment and/or <br /> methods proposed to monitor leachate penetration of the clay liners, the testing <br /> frequency, and the pass/fail criteria to evaluate liner testing. The monitoring <br /> system shall be sufficient to detect leachate penetration to a depth 12 inches <br /> above the base of each liner. <br /> The Discharger shall implement the above monitoring program on the effective date <br /> of this Order. <br /> Ordered by C yJ _ @"L <br /> WILLIAM H. CROOKS, Executive Officer <br /> 28 February 1992 <br /> Date <br /> WJM:JEB <br />
The URL can be used to link to this page
Your browser does not support the video tag.