My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1444
>
2200 - Hazardous Waste Program
>
PR0535125
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2024 4:33:23 PM
Creation date
10/9/2019 9:26:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535125
PE
2227
FACILITY_ID
FA0016178
FACILITY_NAME
URS MIDWEST INC DBA UNITED ROAD
STREET_NUMBER
1444
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
APN
11736030
CURRENT_STATUS
01
SITE_LOCATION
1444 EL PINAL DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STI Aboveground Storage Tank Report Formal External Inspection COVEY AUTO EXPRESS,Stockton, CA <br /> Storage Tank Report 1/21/2014 Tank No.2—Used Oil Weather: Clear moderate <br /> Inspection Goal Methods Employed Results <br /> 7.2 DETERMINE ORIGINAL SHELL THICKNESS <br /> 7.2.1 Review original documentation. Not Available <br /> 7.2.2 Consult tank manufacturer. <br /> 7.23 Examine tank labels for evidence of widely accepted tank N/A <br /> standard,such as Underwriters Laboratories standard UL342. <br /> 7.2.4 Measure shell thickness of several areas with no corrosion 0.105 IN,12 ga <br /> measured UTT <br /> 7,3 HORIZONTAL AST Requirements in addition to applicable items in 7.1: HORIZONTAL <br /> 7.3.1 Inspect shell plates, Inspect areas accessible without entering AST. Concentrate Sound but dented <br /> welds where corrosion is likely.If significant internal corrosion is <br /> detected,further investigation using Ultrasonic Testing Scans <br /> (UTS)is required. <br /> 7.3.2 Inspect shell Inspect for changes made after AST was fabricated.Record N/A <br /> attachments repads and/or insert plates.Inspect welds for signs of stress <br /> and corrosion. <br /> 7,4 VERTICAL or Requirements in addition to applicable items In 7.1: N/A <br /> RECTANGULAR AST <br /> 7.4.1 Inspect shell plates, Inspect areas accessible without entering AST. Concentrate OK Ultra sonic <br /> welds where corrosion is likely.If significant internal corrosion is measurements,visible <br /> detected,further investigation using UTS Is required. underneath&on PCC floor <br /> 7,4,2 Inspect shell Inspect for changes made after AST was fabricated. Record WA <br /> attachments repads and/or insert plates.Inspect welds for signs of stress <br /> and corrosion. <br /> 7.4.3 Vertical AST Roof Inspect for low areas,standing water,paint failure,holes and N/A <br /> corrosion.Take Ultrasonic Thickness Testing(UTT)readings on <br /> roof and record results. If significant internal corrosion is <br /> detected,further Investigation using UTS is required. <br /> 7,4,4 DOUBLE WALL& Requirements in addition to applicable items in 7.1: N/A <br /> DOUBLE BOTTOM AST <br /> 7.4,5 Leak Detection Verify that the leak detection equipment method is operating N/A <br /> if the tank is so equipped. <br /> 7.4.6 Inspect Interstice Check for leak or liquid in interstice,not vented to N/A <br /> atmosphere. <br /> 7.4.7 Double—bottom Double-bottom ASTs require UTT readings of areas that are N/A <br /> sin le•wall.Double-wall ASTs do not require UTT readings. <br /> 7,5 INSULATED AST Requirements in addition to applicable items In 7.1 to 7.4. N/A <br /> 7.5.1 Remove insulation Remove insulation in areas where mold or moisture is present N/A <br /> or likely to accumulate and examine metal surface for corrosion. <br /> 7.5.2 Verify damage extent If insulation damage is suspected,removeinsulation until N/A <br /> extent and nature of corrosion has been established. <br /> 7.5.3 Take tTrT readings Take LITT readings an shell and record results. If significant N/A <br /> corrosion is detected,further investigation using UTS is <br /> required. <br /> 7.5.6 FIELD ERECTED AST Additional requirements for field-erected ASTs are included in N/A <br /> SP001 Appendix B. <br /> 7,7 FINAL REPORT Include:Field data,measurements,pictures,drawings,tables Dated 1/21/14 Re-inspect <br /> and an inspection summary,identify unacceptable conditions in 5years or as specified in <br /> and recommended corrective actions.Determine the SPCCP or hazardous waste <br /> suitability forcontinued service.Include the next scheduled regulations <br /> formal external or Internal inspection as applicable.Include <br /> inspectors name and certification number in the report <br />