GENERAL NOTES <br />A. GENERAL REQUIREMENTS <br />1. CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING CODE 2013 EDITION (HEREINAFTER REFERRED <br />TO AS THE CODE), ALL APPLICABLE ORDINANCES AND REGULATIONS, THE SPECIFICATIONS AND THE <br />DRAWINGS. <br />2. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING <br />THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF ALL PERSON AND PROPERTY. <br />THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE <br />CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION AS NECESSARY AND REQUIRED BY GOVERNING CITY <br />AGENCIES. <br />3. TRADE NAMES AND MANUFACTURES REFERRED TO ARE FOR QUALITY SUBMITTED TO AND APPROVED BY THE <br />OWNER AND DESIGNER PRIOR TO THEIR PURCHASE AND INCORPORATION INTO THE WORK. <br />4. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS BASED ON ENTIRE <br />SET OF DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A BIDDER OR SUPPLIER WHO HAS BID <br />FROM AND INCOMPLETE SET OF CONSTRUCTION DOCUMENTS. IN CASE OF INCONSISTENCIES OR <br />DISCREPANCIES BETWEEN DRAWINGS THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE <br />CONTRACTOR SHALL NOTIFY OWNER/ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. <br />5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR ON THE FIELD TO VERIFY EXISTING SITE CONDITIONS AND <br />DIMENSIONS PRIOR TO STARTING CONSTRUCTION. THE CONDITIONS SHOWN ON THESE DOCUMENTS ARE <br />BASED ON INFORMATION SUPPLIED BY LANDLORD. <br />6. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE <br />DURING CONSTRUCTION. THE CONTRACTOR SHALL INDICATE ON THESE PLANS ALL APPROVED CHANGES TO <br />THIS WORK. THIS SET SHALL BE TURNED OVER TO OWNER/ARCHITECT WHEN THE PROJECT IS COMPLETE. <br />7. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR ON THESE DRAWING, SPECIFICATIONS OR OTHER <br />CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY OWNER/ARCHITECT IMMEDIATELY. <br />8. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING TO OWNER\ARCHITECT FOR <br />APPROVAL IN WRITING. NOTIFICATION MUST BE SUBMITTED WITHIN 10 WORKING DAYS OF CONTRACT AWARD. <br />9. THE CONTRACTOR IS REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED AND SUBMIT <br />LIST TO THE OWNER/ARCHITECT WITHIN 10 WORKING DAYS OF CONTRACT AWARD. <br />10. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING IN AND VERIFYING ALL SHIPMENTS OF OWNER SUPPLIED <br />MATERIALS. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS AND BILLS OF LOADING. IF <br />THIS IS NOT DONE, THE CONTRACTOR WILL BEAR THE COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET <br />THE CONSTRUCTION SCHEDULE. THE CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND <br />MUST MAINTAIN PACKING MATERIALS FOR SHIPMENT OF DAMAGED ITEMS. <br />11. THE CONTRACTOR SHALL KEEP ALL HANDBOOKS AND PAPERWORK INCLUDING ALL PACKING SLIPS LADING IN <br />A MARKED ENVELOPE. THIS ENVELOPE IS TO BE TURNED OVER TO OWNER. <br />12. THE CONTRACTOR SHALL DELIVER TO OWNER A COPY OF THE CERTIFICATE OF OCCUPANCY, LIEN WAIVER, <br />WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. THE ORIGINAL CERTIFICATE OF <br />OCCUPANCY TO BE FRAMED AND MOUNTED AT STORE MANAGER'S DESK. <br />13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP OF ALL TRADES. <br />14. THE DRAWINGS ARE NOT TO BE SCALED. <br />15. THESE DRAWING ARE NOT TO BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION FROM OWNER OR <br />FROM OWNER'S ARCHITECT. <br />16. COORDINATE CONSTRUCTION TIME AND NOISE REQUIREMENTS WITH BUILDING OWNER. <br />17. UPON COMPLETION OF CONSTRUCTION, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CLEAN ALL <br />FINISH SURFACES AS PER MANUFACTURER'S INSTRUCTIONS AND TO EMPLOY THE SERVICES OF A <br />PROFESSIONAL CLEANING COMPANY IN ORDER TO ASSURE THE OWNER OF AN ABSOLUTELY CLEAN STORE. IF <br />AN UNTIDY STORE IS TURNED OVER, THE OWNER RESERVES THE RIGHT TO EMPLOY SIMILAR CLEANING <br />SERVICES AND TO DEDUCT THE COST PLUS 10% FROM THE BALANCE OF THE CONTRACTOR'S CONTRACT <br />SUM. <br />18. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OF ALL EQUIPMENT, MERCHANDISE, CARPET, AND <br />ETC. <br />19. CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING OF STUDS, INSERTS AND BLOCKING AS REQUIRED. <br />20. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS <br />MAY BE REQUIRED TO SUIT THE JOB DIMENSIONS OR CONDITIONS AND SHALL BE INCLUDED AS PART OF <br />THE WORK. <br />21. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING ANY WORK. <br />22. VERIFY LOCATION AND SIZE OF ALL OPENINGS WITH ALL DRAWINGS AND MANUFACTURED ITEMS WHERE <br />APPLICABLE. <br />23. VERIFY INSERTS AND EMBEDDED ITEMS WITH ALL DRAWINGS AND MANUFACTURED ITEMS WHERE APPLICABLE. <br />24. GLASS AND GLAZING SHALL CONFORM WITH THE CODE, CHAPTER 24 AND TO U.S. CONSUMER PRODUCT <br />SAFETY COMMISSION REQUIREMENTS. GLAZED OPENINGS LESS THAN 18 INCHES ABOVE ADJACENT FLOOR <br />SHALL BE TEMPERED GLASS APPROVED FOR IMPACT HAZARD. <br />25. LATHING, PLASTERING AND GYPSUM DRYWALL SHALL CONFORM TO THE CODE, CHAPTER 25. GYPSUM <br />DRYWALL FASTENERS SHALL BE INSPECTED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE JOINTS <br />ARE TAPED. ALL DRYWALL SHALL BE 5/8" THICK, TYPE "X" 1 -HOUR UNLESS OTHERWISE NOTED. <br />26. IN ALL INSTANCES PROVIDE ISOLATION OF ALUMINUM FROM ADJACENT STEEL.. <br />27. PROVIDE ALL NECESSARY BACKING AND FRAMING FOR WALL MOUNTED ITEMS, LIGHT FIXTURES AND ALL <br />OTHER ITEMS REQUIRING SAME. <br />28. ALL INSULATION, INCLUDING FACINGS, SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25 AND A <br />SMOKE DENSITY NOT EXCEEDING 450. AS PER C.B.C. 720.2 <br />29. GREEN BUILDING GUIDELINES. TO THE EXTENT PRACTICAL, THE APPLICANT SHALL INCORPORATE GREEN <br />BUILDING MEASURES. GREEN BUILDING PLAN SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR REVIEW. <br />(THROUGH COMPLETION) <br />30. A MINIMUM OF 7'-6" HEADROOM CLEARANCES IS REQUIRED ABOVE ANY FINISH FLOOR TO ANY CEILING, <br />BEAM, PIPE OR SIMILAR CONSTRUCTION PER C.B.C. 12.08.2. <br />31. ALL RAMP SURFACES SHALL BE SLIP RESISTANT. <br />32. ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL HAVE A DESIGN LISTING/NUMBER. ANY EQUIPMENT <br />NOT LISTED WILL BE REQUIRED TO BE FIELD TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY. IT <br />IS THE RESPONSIBILITY OF THE OWNER AND HIS DESIGN/CONSTRUCTION TEAM TO NOTIFY THE BUILDING <br />DEPARTMENT IF FIELD-TESTING IS REQUIRED FOR ANY EQUIPMENT WITHOUT AN EQUIVALENT LISTED LABEL <br />APPROVED BY THE FREMONT BUILDING DEPARTMENT. PROOF OF EQUIPMENT CERTIFICATION WILL NEED TO BE <br />SUBMITTED AND APPROVED BEFORE A CERTIFICATE OF OCCUPANCY CAN BE ISSUED. <br />33. EQUIPMENT INSTALLATION MAY REQUIRE SEPARATE PERMITS: PROVIDE CALCULATIONS AND ANCHORAGE <br />DETAILS FOR ALL EQUIPMENT WEIGHING 400 LBS. OR MORE. NOTE THAT EQUIPMENT AT ANY WEIGHT <br />MOUNTED AT MORE THAN 4 FEET ABOVE FLOOR HEIGHT SHALL BE PROVIDED WITH ANCHORAGE. [ASCE <br />7-10 SEC. 13.1.4] <br />34. IT IS THE APPLICANT'S RESPONSIBILITY TO CONTACT THE FREMONT FIRE DEPARTMENT AT 510-494-4200 <br />TO SUBMIT A HAZARDOUS MATERIAL BUSINESS PLAN (HMBP) AS NEEDED FOR THIS PERMIT. BUILDING FINAL <br />MAY BE IMPACTED IF THIS ITEM IS NOT SUBMITTED FOR COORDINATION. <br />35. A SEPARATE PERMIT IS REQUIRED PRIOR TO WORK ON ANY FIRE PROTECTION SYSTEMS OR COMPONENT. <br />SUBMIT THREE SETS OF SHOP DRAWINGS, CALCULATIONS AND SPECIFICATIONS. <br />36. SEPARATE PERMIT(S) ARE REQUIRED FOR ALL SHELVING AND RACKING INSTALLATIONS. <br />B. GENERAL DIMENSION NOTES <br />1. DIMENSIONS ON PLANS ARE FINISHING TO FINISHING. OF COLUMNS TYPICALLY. UNLESS NOTED OTHERWISE <br />(U.N.O.) <br />FIRE DEPARTMENT & FIRE PROTECTION NOTES <br />1. CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED. VERIFY QUANTITY AND LOCATION WITH LOCAL <br />OFFICIALS AND COORDINATE LOCATION OF SAME WITH ARCHITECT. <br />2. A KNOX BOX IS REQUIRED FOR EACH BUILDING FOR COMMON AREA ACCESS. KNOX BOXES ARE REQUIRED FOR <br />EACH TENANT SPACE BEFORE OCCUPANCY. <br />3. THE PROJECT SHALL COMPLY WITH BUILDING AND FIRE CODES AS ADOPTED BY THE COUNTY OF SAN JOAQUIN. <br />4. THE APPLICANT SHALL INSTALL A NFPA 13 FIRE SPRINKLER SYSTEM COMPLYING WITH LOCAL AMENDMENTS. <br />SEPARATE CONTROL VAVLES/WATER FLOW SWITCHES REQUIRED FOR EACH FLOOR. <br />5. THE APPLICANT SHALL INSTALL FIRE ALARM SYSTEM AS REQUIRED. THE SYSTEM MUST BE MONITORED. THE <br />SYSTEM MUST BE NFPA 72 COMPLIANT AND HAVE AN INTERIOR AUDIBLE DEVICE PER THE C.F.C. UPON <br />COMPLETION A "UL" SERIAL NUMBERED CERTIFICATE SHALL BE PROVIDED AT NO COST TO THE COUNTY OF <br />SAN JOAQUIN FIRE AND LIFE SAFETY INSPECTOR. FIRE ALARM SYSTEMS DEVICES SHALL BE ADDRESSABLE <br />AND REPORT TO THE CENTRAL MONITORING STATION ADDRESSABLE. <br />6. SEPARATE PERMIT IS REQUIRED FOR THE UNDERGROUND FIRE SERVICE, FIRE SPRINKLER AND U.L. CERTIFICATED <br />FIRE SYSTEMS. <br />7. PUBLIC FIRE HYDRANTS HEAD WITHIN 300 FT. OF SITE TO BE A CLOW MODEL 860 OR EQUIVALENT. FIRE <br />HYDRANTS SPACING REQUIREMENT IS 300 FEET INTERVALS. <br />8. THE APPLICANT SHALL COMPLY WITH COUNTY OF SAN JOAQUIN CODE REQUIREMENTS FOR INSTALLATION OF <br />FIRE RETARDANT ROOF COVERINGS. <br />9. THE APPLICANT SHALL PROVIDE THE FIRE HYDRANT REQUIRED FIRE FLOW ON SITE PRIOR TO CONSTRUCTION <br />OR STORAGE OF COMBUSTIBLE MATERIALS. FIRE HYDRANT JUMPER LINES MUST BE AT LEAST 6 INCHES IN <br />DIAMETER. THIS MUST BE COMPLETED AND INSPECTED BEFORE ANY CONSTRUCTION OR MATERIALS STORAGE <br />WILL BE ALLOWED. <br />10. THE APPLICANT SHALL HAVE A KEY BOX (KNOX BRAND) LOCATED OUTSIDE OF BUILDINGS/GATES AND PROVIDE <br />KEYS TO THE FIRE DEPARTMENT SO THEY MAY GAIN ACCESS. <br />11. ADDRESS MUST ALWAYS BE VISIBLE FROM PUBLIC STREET. <br />12. THE APPLICANT SHALL INDICATE ON ALL SITE PLANS THE LOCATION OF REQUIRED RED CURBS, CURB <br />LETTERING AND FIRE LANE SIGNS. THIS PROJECT REQUIRES ALL CURBS TO BE RED, LETTERING EVERY 30 FEET <br />AND SIGNS EVERY 100 FEET. <br />13. ALL REQUIRED EXISTS SHALL BE OPENABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT. <br />14. PROVIDE ONE 2A RATED FIRE EXTINGUISHER FOR EACH 75' OF TRAVEL AND ON EACH FLOOR LEVEL, PROVIDED <br />THAT ONE EXTINGUISHER IS SUPPLIED FOR EACH 6,000 SQUARE FEET OR FRACTION THEREOF. PROVIDE <br />OTHER LOCATIONS PER FIRE MARSHAL. <br />15. PORTABLE FIRE EXTINGUISHER SHALL BE HUNG NO MORE THAN 5 FEET (5) HIGH IN LOCATIONS AS <br />DESIGNATED BY THE LOCAL FIRE DEPARTMENT. THEY SHALL BE HOUSED IN A CABINET. THEY SHALL BE IN <br />NORMAL PATHS OF TRAVEL AND SIGNS SHALL BE CONSPICUOUS. <br />16. ASSEMBLY ROOMS <br />i. POST OCCUPANT CAPACITY SIGN WITH ONE INCH (1") HIGH LETTERS. BASED UPON ASSEMBLY 15 <br />SQUARE FEET PER PERSON FOR ALL ASSEMBLY ROOMS. <br />ii. INTERIOR FINISH SHALL CONFORM TO C.B.C. CHAPTER 8 <br />iii. ANY DECORATION USED SHALL BE NON-COMBUSTIBLE OR FLAME PROOFED IN A MANNER APPROVED BY <br />THE BUILDING DEPARTMENT. <br />iv. EXIT DOORS, EXIT LIGHTS FIRE ALARM SENDING STATION AND FIRE EXTINGUISHER LOCATIONS SHALL NOT <br />BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. <br />17. FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE RATED WALLS OR CEILINGS. <br />FIRE STOPPING SHALL BE PROVIDED AT ALL PENETRATIONS (PIPES, DUCTS, CONDUITS CABLES AND WIRING <br />NOT IN CONDUITS) AS PER ASTM E 814-94 AND C.B.C. 716.2-716.5. <br />18. PROVIDE A MINIMUM OF ONE 2A10BC FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 3,000 <br />SQ. FEET OR PORTION THEREOF ON EACH FLOOR. (C.F.C. 906 AND CAL CODE REGS. TITLE 19, CHAPTER 3). <br />19. PROVIDE PORTABLE CLASS K FIRE EXTINGUISHER WITHIN 30 FEET OF THE KITCHENS WITH COMMERCIAL FOOD <br />HEAT -PROCESSING EQUIPMENT PER C.F.C. 906.1.2 <br />20. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. <br />21. PROVIDE AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM PER CALIFORNIA BUILDING CODE. SYSTEM SHALL <br />BE INSTALLED 100% THROUGHOUT. <br />22. SEPARATE PLANS FOR AUTOMATIC FIRE SPRINKLER SYSTEM, FIRE ALARM SYSTEMS, AND ANY OTHER PLANS <br />FOR FIXED FIRE PROTECTION EQUIPMENT SHALL BE SUBMITTED TO THE FIRE MARSHAL FOR APPROVAL PRIOR <br />TO INSTALLATION. <br />23. PROVIDE SMOKE DETECTORS IN SUPPLY AND RETURN AIR DUCTS FOR ALL HVAC UNITS 2000 CFM/5-TON OR <br />LARGER OR SMALLER UNITS COLLECTIVELY SERVING A COMMON AREA. ALL UNITS SHALL BE ARRANGED TO <br />SHUT DOWN SIMULTANEOUSLY. <br />24. CONTINUOUS INSPECTION WILL BE REQUIRED FOR ALL SPRAY -ON FIRE PROOFING OPERATIONS PER C.B.C. <br />CHAPTER 17. <br />25. AUDIBLE AND VISUAL ALARMS WILL COMPLY WITH THE PROVISIONS OF NFPA 72G <br />26. BUILDING IS PROVIDED WITH AUTOMATIC FIRE EXTINGUISHING SYSTEMS. SYSTEMS SERVING MORE THAN <br />20 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM. <br />27. ALL PORTIONS OF THE BUILDING SHALL BE WITHIN 75 FEET OF FIRE EXTINGUISHER. tHE MINIMUM <br />SIZE OF THE EXTINGUISHER SHALL BE 2 -A:10 -BC. <br />28. APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED ON ALL NEW AND EXISTING BUILDINGS IN SUCH A <br />POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. <br />SAID NUMBER SHALL CONTRAST WITH THEIR BACKGROUND. <br />29. STORAGE - STORAGE OF COMBUSTIBLES SHALL BE LIMITED TO AS ALLOWED BY CFC. <br />30. INDOOR DISPLAYS - FIXTURES AND DISPLAYS OF GOODS FOR SALE TO THE PUBLIC SHALL BE ARRANGED SO <br />AS TO MAINTAIN FREE, IMMEDIATE AND UNOBSTRUCTED ACCESS TO EXITS AS REQUIRED BY CHAPTER 10 OF <br />THE CFC. THE DISPLAY OF HIGHLY COMBUSTIBLE GOODS IS PROHIBITED. <br />31. THE 2013 CALIFORNIA FIRE CODE (SECTION 105) REQUIRES A PERMIT FOR THE USE OF ALL A <br />OCCUPANCIES -PLACES OF ASSEMBLY. A FIRE CODE ASSEMBLY PERMIT IS APPLIED FOR AT THE DEVELOPMENT <br />SERVICES CENTER, LOCATED AT 39550 LIBERTY STREET. FEE INFORMATION MAY BE OBTAINED BY CONTACTING <br />THE PERMIT CENTER TO REQUEST A CURRENT FEE SCHEDULE AT 510-494-4460. <br />32. FIRE CODE ASSEMBLY PERMITS MAYBE PLANNED CHECKED BY APPOINTMENT ONLY, ON AN `OVER THE <br />COUNTER" BASIS PROVIDED A COMPLETE PLAN IS SUBMITTED. CONTACT THE PERMIT CENTER AT <br />510-494-4443 TO SCHEDULE AN APPOINTMENT. <br />33. PROVIDE THE FOLLOWING NOTE ON THE COVER SHEET. "A FIRE CODE ASSEMBLY PERMIT IS REQUIRED FOR THIS <br />PROJECT. IT IS THE RESPONSIBILITY OF THE APPLICANT TO OBTAIN THIS PERMIT PRIOR TO PERMIT FINAL." <br />34. PROVIDE OCCUPANT LOAD CALCULATIONS FOR THIS PROJECT AND SHOW THE LOCATION OF THE MAXIMUM <br />OCCUPANT LOAD POSTING ON THE FLOOR PLAN. LOCATION OF THE OCCUPANT LOAD POSTING SHOULD BE IN A <br />CONSPICUOUS LOCATION. SHOW LOCATION ON PLAN. <br />35. INDICATE REQUIRED PANIC HARDWARE ON ALL EXISTING EXIT DOORS IN THE PATH OF ASSEMBLY EXITING. <br />ABBREVIATIONS <br />L ANGLE <br />A.F.F. ABOVE FINISH FLOOR <br />APPROX APPROXIMATE <br />ARCH. ARCHITECTURAL <br />BD. BOARD <br />BLDG. BUILDING <br />BLKG. BLOCKING <br />B.O. BY OTHERS <br />CAB. CABINET <br />CENTER LINE <br />CLG. CEILING <br />CLR. CLEAR <br />C.M.U. CONCRETE MASONRY UNIT <br />COL. COLUMN <br />CONC. CONCRETE <br />CONST. CONSTRUCTION <br />CONT. CONTINUOUS <br />CPT. CARPET <br />C.W. COLD WATER <br />DTL. DETAIL <br />DEMO. DEMOLITION <br />DIA. DIAMETER <br />DIM. DIMENSION <br />DWG. DRAWING <br />EA. EACH <br />ELEV. ELEVATION <br />ELEC. ELECTRICAL <br />EQ. EQUAL <br />EXH. EXHAUST <br /><E> EXISTING <br />EXT. EXTERIOR <br />EXP. EXPANSION <br />E.O. EDGE OF <br />E.W. EACH WAY <br />F.F. FINISH FLOOR <br />FIN FINISH <br />F.O.F. FACE OF FINISH <br />F.O.S. FACE OF STUDS <br />FT. FEET <br />GA. GAUGE <br />GALV. GALVANIZED <br />G.S.M. GALVANIZED SHEET METAL <br />G.W.B. GYPSUM WALLBOARD <br />I.D. INSIDE DIAMETER <br />INCL. INCLUDING <br />INSUL. INSULATION <br />INT. INTERIOR <br />JAN. JANITOR <br />K.S. KNEE SPACE <br />MTL. METAL <br /><N> NEW <br />N NORTH <br />N.I.C. NOT IN CONTRACT <br />NO. / # NUMBER <br />N.T.A. NOT TO SCALE <br />0/ OVER <br />O.C. ON CENTER <br />O.D. OUTSIDE DIAMETER <br />OPNG. OPENING <br />OWSJ OPEN WEB STEEL JOIST <br />P. LAM. PLASTIC LAMINATE <br />PNL. PANEL <br />PR. PAIR <br />RAD RADIUS <br />REC RECESSED <br />RECT RECTANGLE <br />REF REFERENCE <br />REINF REINFORCED /ING <br />REQ REQUIRED <br />R.O. ROUGH OPENING <br />S.C. SOLID CORE <br />S.C.D. SEE CIVIL DRAWINGS <br />SCHED. SCHEDULE <br />S.F. SQUARE FOOT <br />SHT. SHEET <br />SIM. SIMILAR <br />SPECS. SPECIFICATIONS <br />SQ. SQUARE <br />S.S. SANITARY SEWER <br />S/S STAINLESS STEEL <br />S.C.D. SEE CIVIL DRAWING <br />S.E.D. SEE ELECTRICAL DRAWING <br />S.L.D. SEE LANDSCAPE DRAWING <br />S.M.D. SEE MECHANICAL DRAWING <br />S.P.D. SEE PLUMBING DRAWING <br />S.S.D. SEE STRUCTURAL DRAWING <br />STD. STANDARD <br />STL. STEEL <br />STRUCT. STRUCTURAL <br />SUSP. SUSPENDED <br />T.STL. TOP OF <br />TEMP. TEMPERED <br />T..S. TOP OF SLAB <br />TYP. TYPICAL <br />U..N. UNLESS OTHERWISE NOTED <br />V.I.D. VERIFY IN FIELD <br />V.C.T. VINYL COMPOSITE TILE <br />W/ WITH <br />W/0 WITHOUT <br />WIN. WINDOW <br />WD. WOOD <br />PROJECT DIRECTORY <br />VICINITY MAP <br />0 <br />San Joaquin County <br />- y\ Environmental Health Department <br />1868 E. Hazelton Ave. <br />Stockton, CA 95205 <br />(209) 468-3420 <br />AP ROVED WITH CONDITIONS <br />For condi ions, please see approval letter dated: 11-30-18 <br />Approved by: Date: Nov 30, 2018 <br />OWNER <br />85'C BAKERY CAFE <br />APPLICABLE CODES AND REGULATIONS: <br />1415 MOONSTONE ST. <br />CONSTRUCTION TYPE: <br />BREA, CA 92821 <br />ALL PLANS TO COMPLY WITH THE FOLLOWING: <br />TEL: (714) 459-9585 <br />AREA (SF) <br />http://www.85cafe.us <br />ARCHITECT <br />TECTONIC BUILDER CORP., <br />YES <br />10118 BANDLEY, #E <br />#20-2016 <br />CUPERTINO, CA 95014 <br />3 <br />TEL: (408) 216-0804 <br />#21-2016 <br />LARRY WANG <br />2286 S.F. <br />Iarrywang@tectoniccorp.com <br />PLUMB., <br />JHP ENGINEERING AND <br />ELEC. & MECH <br />DESIGN, INC. <br />CONSULTANTS <br />3119 CENTRAL PARKWAY <br />369 S.F. <br />DUBLIN, CA 94568 <br />#21-2016 <br />TEL: (510) 788-6029 <br />5,000 <br />JIA PAN <br />#21-2016 <br />Ihpengr@gmail.com <br />STRUCTURAL <br />DMAC DESIGN + BUILD <br />#21-2016 <br />5690 SCHAEFER AVE, SUITE A, <br />(EXISTING) <br />CHINO, CA 91710 <br />2247 <br />(909) 927-8688x110 <br />DUNCAN CHEN <br />TOTAL OCCUPANT LOAD = 16 <br />50% MALE= 8 <br />50% FEMALE = 8 <br />dchen@dmacse.com <br />SCOPE OF WORK <br />r <br />B k <br />a ey Cafe <br />IPD- <br />878 W. BENJAMIN HOLT DR., STOCKTON, CA 95207 <br />Lincoln Rd <br />2 <br />b <br />W LIncoln Ind <br />Clarane Ave <br />74 <br />n <br />Bank of America <br />Financial Center <br />W815 West Benjamin <br />+' t Drive <br />°062�` 0 v <br />` Trader Joe's Chuck E. Cheese's <br />r�}3e4tid��� <br />�¢d9�%A <br />W�1 <br />Safeway <br />• TENANT IMPROVEMENT OF A EMPTY SHELL IN AN EXISTING ONE STORY BLDG. <br />• WORKS INCLUDING NEW ENTRY TOWER, WALLS, CEILINGS, INTERIOR FINISHES, NEW RESTROOMS, ELECTRICAL, MECHANICAL, AND PLUMBING. AS <br />SHOWN ON PLANS <br />• RELOCATE EXISTING STOREFRONTS <br />SHEET INDEX <br />ARCHITECTURAL <br />AO.0 TITLE SHEET <br />A1.0 ACCESSIBILITY NOTES <br />A1.1 CALGREEN NOTES <br />A2.0 SITE PLAN <br />A2.1 DEMOLITION PLAN <br />A2.2 ROOF PLAN <br />A2.3 EXIT ANALYSIS <br />A3.0 FLOOR PLAN <br />A3.1 EQUIPMENT PLAN <br />A3.2 EQUIPMENT SCHEDULE <br />A3.4 FINISH PLAN <br />A3.5 REFLECTED CEILING PLAN <br />A4.0 SECTIONS <br />A5.0 ENLARGED RESTROOM PLAN & ELEVATIONS <br />A6.0 INTERIOR ELEVATIONS <br />A6.1 INTERIOR ELEVATIONS <br />A6.2 EXTERIOR ELEVATIONS <br />A7.0 DOOR SCHEDULE <br />A8.0 DETAILS <br />A8.1 DETAILS <br />A8.2 DETAILS <br />A8.3 DETAILS <br />A8.4 DETAILS <br />A8.5 MANAGER STATION DETAILS <br />STRUCTURAL <br />SN1 STRUCTURAL NOTES <br />S1 FOUNDATION PLAN <br />S2 FLOOR FRAMING PLAN <br />S3 ROOF FLAMING PLAN <br />SD1 STRUCTURAL DETAILS <br />SD2 STRUCTURAL DETAILS <br />HFX1 ANCHORAGE DETAILS-HFX PANELS <br />HFX2 FRAMING DETAILS- HFXPANELS <br />MECHANICAL <br />ME -0.1 MECHANICAL NOTES AND GENERAL INFORMATION <br />ME -0.2 MECHANICAL SCHEDULES <br />ME -0.3 MECHANICAL DETAILS <br />ME -0.4 MECHANICAL PERSCRIPTIVE TITLE 24 COMPLIANCE <br />ME -0.5 MECHANICAL PERSCRIPTIVE TITLE 24 COMPLIANCE <br />ME -0.6 MECHANICAL PERSCRIPTIVE TITLE 24 COMPLIANCE <br />ME -0.7 MECHANICAL PERSCRIPTIVE TITLE 24 COMPLIANCE <br />ME -1.0 MECHANICAL REFLECTED CEILING PLAN <br />ME -2.0 ROOF MECHANICAL PLAN <br />ME -3.0 KITCHEN HOOD DETAILS <br />ME -3.1 KITCHEN HOOD EXHAUST FAN DETAIL AND WIRING <br />DIAGRAM <br />PLUMBING <br />PB -0.1 PLUMBING NOTES AND GENERAL INFORMATION <br />PB -0.2 PLUMBING SCHEDULES, CALCULATION, AND TABLES <br />PB -0.3 PLUMBING DETAILS <br />PB -0.4 PLUMBING DETAILS <br />PB -1.0 GROUND FLOOR DOMESTIC WATER PIPING PLAN <br />PB -1.1 GROUND FLOOR WASTE AND VENT PIPING PLAN <br />PB -1.2 GROUND FLOOR GAS AND PIPING PLAN <br />PB -2.0 ROOF PLUMBING PLAN <br />ELECTRICAL <br />E-0.1 SPECIFICATIONS, ABBREVIATION, AND LEGEND <br />E-0.2 TITLE 24 COMPLIANCE FORM <br />E-0.3 TITLE 24 COMPLIANCE FORM <br />E-0.4 TITLE 24 COMPLIANCE FORM <br />E-0.5 TITLE 24 COMPLIANCE FORM <br />E-1.0 POWER PLAN - GROUND FLOOR <br />E-1.1 POWER PLAN - ROOF <br />E-1.2 SINGLE -LINE AND PANEL SCHEDULES <br />E-2.0 LIGHTING PLAN <br />PROJECT DATA <br />PROJECT ADDRESS: 878 W. BENJIMIN HOLT DR., <br />STOCKTON, CA 95207 <br />COMMUNITY <br />DEVELOPMENT: <br />DEPARTMENT: <br />ENVIRONMENTAL <br />HEALTH <br />DEPARTMENT: <br />1810 E. HAZELTON AVE., <br />STOCKTON, CA 95205 <br />209-468-3121 <br />1868 E. HAZELTON AVE.,. <br />STOCKTON, CA 95205 <br />209-468-3420 <br />PROJECT LOCATION <br />JeaS� A`'�r <br />W Lincoln Rd <br />,a <br />Felton Way <br />v <br />ti <br />e <br />Z <br />W Benjamin Hoh Dr <br />Maxine Hang Kingston <br />Elementary School <br />qutncV Gl <br />John Adams <br />Elementary Schaal <br />p l e <br />DEFERRED SUBMITTAL <br />• FIRE ALARM <br />• AUTOMATIC FIRE SPRINKLER <br />BUILDING CODES <br />OCCUPANCY GROUP: <br />B <br />APPLICABLE CODES AND REGULATIONS: <br />E.C. <br />CONSTRUCTION TYPE: <br />TYPE V-A <br />ALL PLANS TO COMPLY WITH THE FOLLOWING: <br />L.W. <br />AREA (SF) <br />OCCUPANT LOAD FACTOR (SF) <br />CITY ORDINANCE <br />FIRE SPRINKLER: <br />YES <br />2016 CALIFORNIA FIRE CODE <br />#20-2016 <br />3 <br />2016 CALIFORNIA BUILDING CODE <br />#21-2016 <br />PROJECT GROSS AREA: <br />2286 S.F. <br />2016 CALIFORNIA RESIDENTIAL CODE <br />#21-2016 <br />KITCHEN AREA <br />2016 CALIFORNIA MECHANICAL CODE <br />#21-2016 <br />PROPOSED TOWER AREA: <br />369 S.F. <br />2016 CALIFORNIA PLUMBING CODE <br />#21-2016 <br />232 <br />5,000 <br />2016 CALIFORNIA ELECTRICAL CODE <br />#21-2016 <br />PARKING SPACES: <br />NOT ALTERED <br />2016 CALIFORNIA GREEN BUILDING STANDARDS <br />#21-2016 <br />N/A <br />(EXISTING) <br />2016 CALIFORNIA ENERGY EFFICIENCY STANDARDS (TITLE 24) <br />COUNTY OF SAN JOAQUIN MUNICIPAL CODE <br />PLUMBING FIXTURE ANALYSIS <br />Plumbinq Fixture Analvsis <br />NOTE <br />1. THE CALCULATION IS IN COMPLIANCE W/ C.P.C. 2016 CHAPTER 4 AND C.P.C. TABLE 422.1 <br />2. WHERE FOOD IS CONSUMED INDOORS, WATER STATIONS SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAINS. DRINKING <br />FOUNTAINS SHALL NOT BE REQUIRED FOR AN OCCUPANT LOAD OF 30 OR LESS, PER CPC SEC.415.2 <br />3. THE TOTAL NUMBER OF REQUIRED WATER CLOSETS FOR FEMALES SHALL BE NOT LESS THAN THE TOTAL NUMBER OF REQUIRED WATER <br />CLOSETS AND URINALS FOR MALES. THIS REQUIREMENT SHALL NOT APPLY WHEN SINGLE OCCUPANCY TOILET FACILITIES ARE PROVIDED FOR EACH <br />SEX IN AND A ORE OCCUPANCY WITH AN OCCUPANT LOAD OF LESS THAN 50. EITHER: A. THE REQUIRED URINAL SHALL BE PERMITTED TO BE <br />OMITTED OR, B. IF INSTALLED, THE URINAL SHALL NOT REQUIRE A SECOND WATER CLOSET TO BE PROVIDED FOR THE FEMALE., PER CPC <br />SEC.422.1. NOTE 3. <br />TECTONIC BUILDERS <br />CORPORATION <br />10118 BANDLEY DR. #E, <br />CUPERTINO, CA 95014 <br />TEL: (408) 216-0804 <br />These drawings and the accompanying specifications are exclusive <br />property of TECTONIC BUILDERS CORP. written permission is rewired <br />by TECTONIC BUILDERS CORP. to re -use or to reproduce these <br />drawings as specifications by any method in whole or in part. A written <br />consent is reruired if the drawings are be used by other(s) than assigned <br />contractor(s). Any uestion raised from these drawings should be directed <br />to TECTONIC BUILDERS CORP. in written format. <br />REVISIONS BY <br />RELEASED DATE <br />11-08-2018 1ST SUBMITTAL <br />CO <br />A <br />\'tea <br />LARRY L. WANG <br />C-31807 <br />RENEWAL 1/31/2 <br />OF <br />SHEET CONTENTS: <br />TITLE SHEET, PROJECT DATA, PLUMBING <br />FIXTURE ANALYSIS, GENERAL NOTES, <br />VICINITY MAP <br />�850C Bakery Cafe <br />85 BAKERY STOCKTON <br />878 W. BENJAMIN HOLT DR., <br />STOCKTON, CA 95207 <br />DRAWN: <br />E.C. <br />CHECKED: <br />OCCUPANCY GROUP: A-2 OCCUPANCY <br />L.W. <br />AREA (SF) <br />OCCUPANT LOAD FACTOR (SF) <br />NO. OF OCCUPANTS <br />SEATING AREA (A) <br />JOB NO.: <br />62 <br />30 <br />3 <br />RETAIL(M) <br />FILE NAME: <br />676 <br />200 <br />3 <br />KITCHEN AREA <br />1,124 <br />2,000 <br />1 <br />STORAGE AREA (S) <br />232 <br />5,000 <br />1 <br />RESTROOMS <br />153 <br />N/A <br />N/A <br />TOTAL GROSS FLR. AREA = <br />2247 <br />TOTAL OCCUPANT LOAD = <br />8 <br />TOTAL OCCUPANT LOAD = 16 <br />50% MALE= 8 <br />50% FEMALE = 8 <br />MALE <br />FEMALE <br />WATER <br />CLOSETS <br />URINALS <br />LAVATORIES <br />WATER <br />CLOSETS LAVATORIES <br />DRINKING <br />FOUNTAIN <br />SERVICE SINK <br />TOTAL FIXTURE REQUIRED <br />1 <br />0 <br />1 <br />1 1 <br />N/A <br />1 <br />TOTAL FIXTURE PROVIDED <br />1 <br />1 1 <br />1 1 <br />1 1 <br />N/A <br />1 <br />NOTE <br />1. THE CALCULATION IS IN COMPLIANCE W/ C.P.C. 2016 CHAPTER 4 AND C.P.C. TABLE 422.1 <br />2. WHERE FOOD IS CONSUMED INDOORS, WATER STATIONS SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAINS. DRINKING <br />FOUNTAINS SHALL NOT BE REQUIRED FOR AN OCCUPANT LOAD OF 30 OR LESS, PER CPC SEC.415.2 <br />3. THE TOTAL NUMBER OF REQUIRED WATER CLOSETS FOR FEMALES SHALL BE NOT LESS THAN THE TOTAL NUMBER OF REQUIRED WATER <br />CLOSETS AND URINALS FOR MALES. THIS REQUIREMENT SHALL NOT APPLY WHEN SINGLE OCCUPANCY TOILET FACILITIES ARE PROVIDED FOR EACH <br />SEX IN AND A ORE OCCUPANCY WITH AN OCCUPANT LOAD OF LESS THAN 50. EITHER: A. THE REQUIRED URINAL SHALL BE PERMITTED TO BE <br />OMITTED OR, B. IF INSTALLED, THE URINAL SHALL NOT REQUIRE A SECOND WATER CLOSET TO BE PROVIDED FOR THE FEMALE., PER CPC <br />SEC.422.1. NOTE 3. <br />TECTONIC BUILDERS <br />CORPORATION <br />10118 BANDLEY DR. #E, <br />CUPERTINO, CA 95014 <br />TEL: (408) 216-0804 <br />These drawings and the accompanying specifications are exclusive <br />property of TECTONIC BUILDERS CORP. written permission is rewired <br />by TECTONIC BUILDERS CORP. to re -use or to reproduce these <br />drawings as specifications by any method in whole or in part. A written <br />consent is reruired if the drawings are be used by other(s) than assigned <br />contractor(s). Any uestion raised from these drawings should be directed <br />to TECTONIC BUILDERS CORP. in written format. <br />REVISIONS BY <br />RELEASED DATE <br />11-08-2018 1ST SUBMITTAL <br />CO <br />A <br />\'tea <br />LARRY L. WANG <br />C-31807 <br />RENEWAL 1/31/2 <br />OF <br />SHEET CONTENTS: <br />TITLE SHEET, PROJECT DATA, PLUMBING <br />FIXTURE ANALYSIS, GENERAL NOTES, <br />VICINITY MAP <br />�850C Bakery Cafe <br />85 BAKERY STOCKTON <br />878 W. BENJAMIN HOLT DR., <br />STOCKTON, CA 95207 <br />DRAWN: <br />E.C. <br />CHECKED: <br />L.W. <br />DATE STARTED: <br />2018.08.29 <br />JOB NO.: <br />SCALE: <br />AS NOTED <br />FILE NAME: <br />SHEET NO <br />A0.0 <br />APPROVALSTAMP: <br />