lte�ia # <br />3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR <br />THE DEPOSITING, STORAGE AND COLLECTION, OF NON -HAZARDOUS MATERIALS FOR RECYCLING, <br />FIRE NOTES <br />CAL GREEN NOTES <br />CAL GREEN CHECKLIST <br />INCLUDING (AT A MINIMUM) PAPER, CORRUGATED CARD BOARD, GLASS, PLASTICS, AND METALS OR <br />OR POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF <br />1 <br />1. STORAGE - STORAGE OF COMBUSTIBLES SHALL BE LIMITED TO AS <br />1. PROVIDE 50% WASTE REDUCTION, CONTRACTOR TO PROVIDE DOCUMENT FOR COUNTY OF <br />THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE <br />5.106.4.1.1 <br />/ <br />ALLOWED BY CFC. <br />SAN JPAQUIN REVIEW AND APPROVAL. <br />15. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS MEET THE <br />4 <br />4. DEVELOP A WRITTEN PLAN OF PROCEDURES FOR TESTING AND ADJUSTING SYSTEMS. SYSTEMS TO <br />INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. <br />5 <br />POLLUTANT EMISSION LIMITS. <br />BE INCLUDED FOR TESTING AND ADJUSTING SHALL INCLUDE, AS APPLICABLE TO THE PROJECT: <br />18. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA BUILDING CODE, CCR, TITLE <br />2. INDOOR DISPLAYS - FIXTURES AND DISPLAYS OF GOODS FOR SALE TO <br />2. 100 % OF TREES, STUMPS, ROCKS, AND ASSOCIATED VEGETATION AND SOILS RESULTING <br />A. HVAC SYSTEMS AND CONTROLS <br />24, PART 2 SECTIONS 1203 (VENTILATION) AND CHAPTER 14 (EXTERIOR WALLS). FOR ADDITIONAL <br />ENERGY EFFICIENCY <br />THE PUBLIC SHALL BE ARRANGED SO AS TO MAINTAIN FREE, IMMEDIATE <br />PRIMARILY FROM LAND CLEARING SHALL BE REUSED OR RECYCLED FOR A PHASED PROJECT, SUCH <br />16. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING <br />AND UNOBSTRUCTED ACCESS TO EXITS AS REQUIRED BY CHAPTER 10 <br />MATERIAL MAY BE STOCK PILED ON SITE UNTIL THE STORAGE SITE IS DEVELOPED. <br />WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDE AT LEAST A MINIMUM <br />TECTONIC BUILDERS <br />OF THE CFC. THE DISPLAY OF HIGHLY COMBUSTIBLE GOODS IS <br />EXCEPTION: REUSE EITHER ON OR OFF-SITE, OF VEGETATION OR SOIL CONTAMINATED BY DISEASE OR <br />EFFICIENCY REPORTING VALUE (MERV) OF 8. MERV 8 FILTERS SHALL BE INSTALLED PRIOR TO <br />E. LANDSCAPE IRRIGATION SYSTEMS <br />19. FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM <br />PROHIBITED. <br />PEST INFESTATION. <br />OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE-CORPORATION- <br />REQUIREMENTS OF SECTION 121 (REQUIREMENTS FOR VENTILATION) OF THE 2010 CALIFORNIA ENERGY <br />C O R P O R A T I O N <br />5.303.2 <br />Water Reduction. Plumbing fixture shall meet maximum flow rate values shown in Table 5.303.2.3 <br />INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. <br />INCLUDED <br />11 <br />10118 BANDLEY DR. #E, <br />PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH MANUFACTURER'S <br />NOTES: <br />EXCEPTIONS: <br />5.303.3 <br />CUPERTINO, CA 95014 <br />A. IF CONTAMINATION BY DISEASE OR PEST INFESTATION IS SUSPECTED, CONTACT THE COUNTY <br />5.303.3.1 <br />MAND_GREEN <br />TEL: (408) 216-0804 <br />14 <br />5.303.3.2 <br />AGRICULTURAL COMMISSIONER AND FOLLOW ITS DIRECTION FOR RECYCLING OR DISPOSAL OF THE <br />A. AN ASHRAE 10% TO 15% EFFICIENCY FILTER SHALL BE PERMITTED FOR AN HVAC UNIT <br />2016 CALGreen <br />These drawings and the accompanying specifications are exclusive <br />BY THE TESTING ADJUSTING AND BALANCING BUREAU NATIONAL STANDARDS; THE NATIONAL <br />MATERIAL. (WWW.CDFA.CA.GOV/EXEC/COUNTY/COUNTYCONTACTS.HTML) <br />MEETING THE 2013 CALIFORNIA ENERGY CODE HAVING 60,000 BTU/H OR LESS CAPACITY PER FAN COIL, <br />5.303.3.3.2 <br />property of TECTONIC BUILDERS CORP. written permission is re-uired <br />17 <br />IF THE ENERGY USE OF THE AIR DELIVERY SYSTEM IS 0.4 W/CFM OR LESS AT DESIGN AIR FLOW. <br />NATIONAL STANDARDS OR AS APPROVED BY THE ENFORCING AGENCY. AFTER COMPLETION OF <br />TECTONIC BuILDERs to reuse or to reproduce these <br />18 <br />B. FOR A MAP OF KNOWN PEST AND/OR DISEASE QUARANTINE ZONES, CONSULT WITH THE <br />B. EXISTING MECHANICAL EQUIPMENT <br />DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413, OR OUTDOOR -INDOOR SOUND <br />drmethod in whole or in part. A written <br />by any <br />dr awings as specifications by any <br />consent is reruired if the drawings are be used by other(s) than assigned <br />5.304.1 <br />CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE. (WWW.CDFA.CA.GOV) <br />TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE <br />NIANDATORY- GREEN BUILDING REQL)IRENIENTS CHECIUIST F'OR <br />contractor(s). Any Fuestion raised from these drawings should be directed <br />to TECTONIC BUILDERS CORP. in written format. <br />REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF <br />PRESCRIPTIVE OR PERFORMANCE METHOD IN SECTION 5.507.4.1 OR 5.507.4.2. <br />17. WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF <br />For landscaped areas of at least 1,000 square feet but not more than 5,000 sq ft, separate meters shall be installed for <br />indoor and outdoor water use with Backflow prevention devices. <br />GUARANTIES/ WARRANTIES FOR EACH SYSTEM. 0 & M INSTRUCTIONS SHALL BE CONSISTENT WITH <br />EXCEPTION: <br />5.304.3, 5.304.3.1 <br />BUILDING ENTRIES OUTDOOR AIR INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS <br />NEW AND ADDITIONS OR ALTERATIONS TO NON-RESIDENTIAL BiA7_DINGS <br />BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE OCCUPANTS ARE NOT LIKELY TO BE <br />lte�ia # <br />3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR <br />THE DEPOSITING, STORAGE AND COLLECTION, OF NON -HAZARDOUS MATERIALS FOR RECYCLING, <br />ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS <br />SHEET # /NOTE #1 DETAIL # <br />NEkV I ADD/ALT <br />INCLUDING (AT A MINIMUM) PAPER, CORRUGATED CARD BOARD, GLASS, PLASTICS, AND METALS OR <br />OR POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF <br />1 <br />5.106.1 <br />MEET A LAWFULLY ENACTED LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. <br />THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE <br />5.106.4.1.1 <br />Short Term Bicycle Parkin <br />3 <br />MORE STRINGENT, WHEN ORDINANCES, REGULATIONS OR POLICIES ARE NOT IN PLACE, POST SIGNAGE TO <br />Long Term Bicycle Parkin <br />4 <br />4. DEVELOP A WRITTEN PLAN OF PROCEDURES FOR TESTING AND ADJUSTING SYSTEMS. SYSTEMS TO <br />INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. <br />5 <br />1 5.106.8 <br />BE INCLUDED FOR TESTING AND ADJUSTING SHALL INCLUDE, AS APPLICABLE TO THE PROJECT: <br />18. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF CALIFORNIA BUILDING CODE, CCR, TITLE <br />5.106.10 1 <br />Grading and Paving, Exception for Additions and Alterations not altering the drainage path. <br />A. HVAC SYSTEMS AND CONTROLS <br />24, PART 2 SECTIONS 1203 (VENTILATION) AND CHAPTER 14 (EXTERIOR WALLS). FOR ADDITIONAL <br />ENERGY EFFICIENCY <br />7 <br />B. INDOOR AND OUTDOOR LIGHTING AND CONTROLS <br />MEASURES NOT APPLICABLE TO LOW-RISE RESIDENTIAL OCCUPANCIES, SEE SECTION 5.407.2 OF THIS <br />C. WATER HEATING SYSTEMS <br />CODE. <br />D. RENEWABLE ENERGY SYSTEMS <br />WATER EFFICIENCY & CONSERVATION <br />8 <br />5.303.1.1 <br />E. LANDSCAPE IRRIGATION SYSTEMS <br />19. FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM <br />9 <br />5.303.1.2 <br />F. WATER REUSE SYSTEMS <br />REQUIREMENTS OF SECTION 121 (REQUIREMENTS FOR VENTILATION) OF THE 2010 CALIFORNIA ENERGY <br />10 <br />5.303.2 <br />Water Reduction. Plumbing fixture shall meet maximum flow rate values shown in Table 5.303.2.3 <br />CODE, OR THE APPLICABLE CODE, WHICHEVER IS MORE STRINGENT, AND DIVISION 1, CHAPTER 4 OF CCR, <br />11 <br />5.303.2 <br />PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH MANUFACTURER'S <br />TITLE 8. <br />12 <br />5.303.3 <br />SPECIFICATIONS AND APPLICABLE STANDARDS ON EACH SYSTEM. IN ADDITION TO TESTING AND <br />13 <br />5.303.3.1 <br />ADJUSTING, BEFORE A NEW SPACE CONDITIONING SYSTEM SERVING A BUILDING OR SPACE IS <br />20. FOR BUILDINGS OR ADDITIONS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND <br />14 <br />5.303.3.2 <br />OPERATED FOR NORMAL USE, BALANCE THE SYSTEM IN ACCORDANCE WITH THE PROCEDURES DEFINED <br />VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS <br />15 <br />5.303.3.3.1 <br />BY THE TESTING ADJUSTING AND BALANCING BUREAU NATIONAL STANDARDS; THE NATIONAL <br />OF THE 2013 CALIFORNIA ENERGY CODE, SECTION 120 (C)(4). <br />16 <br />5.303.3.3.2 <br />ENVIRONMENTAL BALANCING BUREAU PROCEDURAL STANDARDS; ASSOCIATED AIR BALANCE COUNCIL <br />17 <br />5.303.4 <br />NATIONAL STANDARDS OR AS APPROVED BY THE ENFORCING AGENCY. AFTER COMPLETION OF <br />21. EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION CLASS (STC) VALUES <br />18 <br />5.303.6 <br />TESTING, ADJUSTING AND BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE <br />DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413, OR OUTDOOR -INDOOR SOUND <br />19 <br />5.304.1 <br />INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. PROVIDE THE BUILDING OWNER OR <br />TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE <br />PAMC <br />16.14.190, <br />Sec 5.303.5 <br />REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF <br />PRESCRIPTIVE OR PERFORMANCE METHOD IN SECTION 5.507.4.1 OR 5.507.4.2. <br />5.304.2 <br />For landscaped areas of at least 1,000 square feet but not more than 5,000 sq ft, separate meters shall be installed for <br />indoor and outdoor water use with Backflow prevention devices. <br />GUARANTIES/ WARRANTIES FOR EACH SYSTEM. 0 & M INSTRUCTIONS SHALL BE CONSISTENT WITH <br />EXCEPTION: <br />5.304.3, 5.304.3.1 <br />A site with at least 1,000 square feet but not more than 2,500 sq ft of landscaped area, design the system and install <br />irrigation hardware which include the following criteria: weather -based or soil moisture -based controllers and meet <br />manufacture's recommendations <br />OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS. INCLUDE <br />BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE OCCUPANTS ARE NOT LIKELY TO BE <br />PAMC 16.14.230 <br />Recycled water infrastructure for landscape irrigation > 1,000 s <br />A COPY OF INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY. <br />AFFECTED BY EXTERIOR NOISE, AS DETERMINED BY THE ENFORCEMENT AUTHORITY, SUCH AS FACTORIES, <br />MATERIAL CONSERVATION & RESOURCE EFFICIENCY <br />23 <br />STADIUMS, STORAGE, ENCLOSED PARKING STRUCTURES AND UTILITY BUILDINGS. <br />Weather Protection <br />24 <br />5. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO <br />Moisture Control (Landscape sprinkler system to prevent spray intrusion into buildings). <br />25 <br />5.407.2.2 <br />CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE <br />EXCEPTION: <br />5.408.1 <br />50% Reduction in construction waste <br />RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING <br />(DSA -SS) FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES, THE REQUIREMENTS OF THIS <br />Excavated soil and land clearing debris (100% reuse or recycle) <br />28 <br />CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF <br />SECTION AND ALL SUBSECTIONS APPLY ONLY TO NEW CONSTRUCTION. <br />29 <br />5.410.2 <br />8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE <br />30 <br />5.410.2.1 <br />- Owner's or Owner representative's Project Requirements (OPR) <br />52.1-1992 REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR IF THE BUILDING IS <br />22. WALL AND ROOF CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING <br />- Basis of Design (BOD) <br />32 <br />OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. <br />OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL MEET A COMPOSITE STC RATING OF AT LEAST 50 <br />33 <br />5.410.2.4 <br />- Functional Performance Testing <br />OR A COMPOSITE OITC RATING OF NO LESS THAN 40, WITH EXTERIOR WINDOWS OF A MINIMUM STC OF <br />5.410.2.5 <br />- Documentation and Training Systems Manual & Systems Operation Training) <br />6. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND <br />40 OR OITC OF 30 IN THE FOLLOWING LOCATIONS: <br />- Commissioning Report <br />36 <br />UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCTS AND <br />A. WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT. <br />37 <br />5.410.4.2 <br />OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, <br />EXCEPTION: <br />5.410.4.3 <br />- Procedures for HVAC Balancing <br />SHEET METAL, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT <br />1. LDN OR CNEL FOR MILITARY AIRPORTS SHALL BE DETERMINED BY THE FACILITY AIR <br />- Reporting <br />40 <br />OF DUST, WATER, AND DEBRIS WHICH MAY COLLECT IN THE SYSTEM. <br />INSTALLATION COMPATIBLE <br />41 <br />5.410.4.5.1 <br />- Inspection and Reports <br />LAND USE ZONE (AICUZ) PLAN. <br />ENVIRONMENTAL QUALITY <br />7. ADHESIVES, SEALANTS, AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF <br />2. LDN OR CNEL FOR OTHER AIRPORTS AND HELIPORTS FOR WHICH A LAND USE PLAN HAS NOT <br />Fireplaces and Woodstoves <br />43 <br />THE FOLLOWING STANDARDS AND TABLE 5.504.4.1, 5.504.4.2 <br />BEEN <br />44 <br />5.504.3 <br />Covering of duct openings and protection of mechanical equipment during construction <br />DEVELOPED SHALL BE DETERMINED BY THE NOISE ELEMENT OF THE GENERAL PLAN. <br />5.504.4.1 <br />Adhesives, sealants and caulks - VOC Limits Table 5.504.4.2 <br />A. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, <br />5.504.4.3 <br />Paints and Coatings - VOC Limits able 5.504.4.2 <br />47 <br />AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY <br />B. WITHIN THE 65 CNEL OR LDN NOISE CONTOUR OF A FREEWAY OR EXPRESSWAY, RAILROAD, <br />48 <br />5.504.4.4 <br />MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN <br />INDUSTRIAL SOURCE OR FIXED -GUIDEWAY SOURCE AS DETERMINED BY THE NOISE ELEMENT OF THE <br />5.504.4.4.1 <br />Carpet Cushion <br />TABLES 5.504.4.1 AND 5.504.4.2. SUCH PRODUCT SHALL COMPLY WITH THE RULE 1168 PROHIBITION <br />GENERAL PLAN. <br />Carpet Adhesive <br />51 <br />ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE, DICHLORIDE, METHYLENE <br />Composite Wood Products - Formaldehyde Limits (Table 5.504.4.5) <br />52 <br />5.504.4.5.3 <br />CHLORIDE, PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS <br />23. FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1, WALL AND ROOF <br />5.504.4.6 <br />Resilient Flooring system 80% <br />SPECIFIED IN SUBSECTION 2, BELOW. <br />CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION ENVELOPE <br />Verification of compliance <br />55 <br />5.504.5.3 <br />OR ALTERED ENVELOPE SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT <br />56 <br />5.504.7 <br />B. AEROSOL, ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR <br />ATTRIBUTABLE TO EXTERIOR SOURCES THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL <br />5.505.1 <br />Indoor Moisture Control <br />CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN <br />(LEQ-1 HR) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION. <br />Outside Air Delivery - for Indoor Air Quality (IAQ) <br />59 <br />ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH <br />Carbon Dioxide (CO2) Monitoring - for buildings or additions <br />60 <br />5.507.4 <br />STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN <br />5.507.4.2.1 SITE FEATURES. <br />5.507.4.1.1 <br />Exterior Noise Transmission, Prescriptive Method <br />TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION <br />EXTERIOR FEATURES SUCH AS SOUND WALLS, OR EARTH BERMS MAY BE UTILIZED AS <br />- Exterior noise transmission for walls and roof -ceiling (50 STC, or 40 01TC <br />63 <br />94507. <br />APPROPRIATE TO THE BUILDING, ADDITION OR ALTERATION PROJECT TO MITIGATE SOUND MIGRATION <br />64 <br />5.507.4.2 <br />Performance Method <br />TO THE INTERIOR. <br />5.507.4.3 <br />Interior sound transmission (wall and ceiling separating tenants to be 40 STC) <br />8. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF <br />5.508.1 <br />Ozone Depletion and Greenhouse reductions - For Outdoor Air Quality <br />67 <br />ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: <br />5.507.4.3 INTERIOR SOUND <br />68 <br />5.508.1.2 <br />- Halons for HVAC, refrigeration, and fire suppression w/o Halons <br />WALL AND FLOOR -CEILING ASSEMBLIES SEPARATING TENANT SPACES AND TENANT SPACES AND <br />5.508.2 <br />Supermarket Refrigerant Leak Reduction (As Applicable for > 8,000 s.f. (N) & Relocated Systems) <br />A. MANUFACTURER'S PRODUCT SPECIFICATION <br />PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40. <br />- Refrigerant Piping <br />71 <br />B. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS <br />- Refrigerant Piping Valves <br />72 <br />5.508.2.2.2 <br />9. CARPET SYSTEMS, ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET AT LEAST ONE <br />73 <br />5.508.2.3 <br />- Refrigerated Service Case <br />OF THE TESTING AND PRODUCT REQUIREMENTS: <br />5.508.2.4 <br />- Refrigerant Receivers <br />75 <br />A. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM. <br />- Pressure Testing <br />76 <br />5.508.2.6 <br />B. COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE <br />MAND 7 Measures <br />CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR TESTING AND EVALUATION OF <br />VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, <br />VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS CDPH STANDARD METHOD V1.1 OR SPECIFICATION <br />01350). <br />C. NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER; <br />D. SCIENTIFIC CERTIFICATIONS SYSTEMS SUSTAINABLE CHOICE; OR <br />E. COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS <br />(CA-CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH <br />PERFORMANCE PRODUCT DATABASE. <br />10. CARPET CUSHION. ALL CARPET CUSHION IN THE BUILDING INTERIOR SHALL MEET THE <br />REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. <br />11. CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 5.504.4.1 <br />12. COMPOSITE WOOD PRODUCTS. HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY <br />FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDINGS <br />SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXICS CONTROL <br />MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ). THOSE MATERIALS NOT EXEMPTED UNDER <br />THE ATCM MUST MEET THE SPECIFIED EMISSION LIMITS, AS SHOWN IN TABLE 5.504.4.5 <br />13. DOCUMENTATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS <br />REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE <br />FOLLOWING: <br />lte�ia # <br />Code Sections <br />REQUIREMENTS <br />SHEET # /NOTE #1 DETAIL # <br />NEkV I ADD/ALT <br />PLANNING AND DESIGN <br />1 <br />5.106.1 <br />Storm Water Pollution Prevention. <br />2 <br />5.106.4.1.1 <br />Short Term Bicycle Parkin <br />3 <br />5.106.4.1.2 <br />Long Term Bicycle Parkin <br />4 <br />A5.106.5.2 <br />Designated parking for fuel efficient vehicles Table 5.106.5.2 <br />5 <br />1 5.106.8 <br />Light Pollution Reduction <br />6 <br />5.106.10 1 <br />Grading and Paving, Exception for Additions and Alterations not altering the drainage path. <br />ENERGY EFFICIENCY <br />7 <br />5.201.1 <br />Meet the minimum Energy Efficiency Standard <br />PAMC 16.18.050 <br />Meet or exceed Energy Efficiency Standard by 1510 (APPLICABLE UNTIL JUNE 30, 2014) <br />WATER EFFICIENCY & CONSERVATION <br />8 <br />5.303.1.1 <br />Separate Meters (add. > 50,000 SF and consume more than 100 gal/day) <br />9 <br />5.303.1.2 <br />Separate Meters (add. consume more than 1,000 gal/day) <br />10 <br />5.303.2 <br />Water Reduction. Plumbing fixture shall meet maximum flow rate values shown in Table 5.303.2.3 <br />11 <br />5.303.2 <br />Water Reduction. Exception: 20 % Indoor Water Savings usin `water use baseline" from Table 5.303.2.2 <br />12 <br />5.303.3 <br />Water Conserving Plumbing Fixtures: <br />13 <br />5.303.3.1 <br />- Water closets shall not exceed 1.28 gallons per flush <br />14 <br />5.303.3.2 <br />- Urinals shall not exceed 0.5 gallons per flush <br />15 <br />5.303.3.3.1 <br />- Single showerhead shall have maximum flow rate of 2.0 gpm (gallons per minute) at 80 psi <br />16 <br />5.303.3.3.2 <br />- Multiple showerheads serving one shower shall have a combined flow rate of 2.0 gpm at 80 psi <br />17 <br />5.303.4 <br />Wastewater Reduction (by 20%) <br />18 <br />5.303.6 <br />Standards for plumbing fixtures and fittings <br />19 <br />5.304.1 <br />Water Budget for Landscape Irrigation <br />PAMC <br />16.14.190, <br />Sec 5.303.5 <br />Install dual plumbing and use of recycled water for toilet and urinal flushing is required for new buildings with area <br />> 10,000 sf and 100 or more toilets and urinals are installed or as required per PAMC 16.14.190. (See recycled water <br />ordinance # 5002, of PAMC 16.12). <br />20 <br />5.304.2 <br />For landscaped areas of at least 1,000 square feet but not more than 5,000 sq ft, separate meters shall be installed for <br />indoor and outdoor water use with Backflow prevention devices. <br />21 <br />5.304.3, 5.304.3.1 <br />A site with at least 1,000 square feet but not more than 2,500 sq ft of landscaped area, design the system and install <br />irrigation hardware which include the following criteria: weather -based or soil moisture -based controllers and meet <br />manufacture's recommendations <br />22 <br />PAMC 16.14.230 <br />Recycled water infrastructure for landscape irrigation > 1,000 s <br />MATERIAL CONSERVATION & RESOURCE EFFICIENCY <br />23 <br />5.407.1 <br />Weather Protection <br />24 <br />5.407.2.1 <br />Moisture Control (Landscape sprinkler system to prevent spray intrusion into buildings). <br />25 <br />5.407.2.2 <br />Moisture Control (Roof overhangs and recessed entries with Nonabsorbent floor and wall finishes within at least four <br />(4) feet around and perpendicular to such openings). <br />26 <br />5.408.1 <br />50% Reduction in construction waste <br />27 <br />5.408.3 <br />Excavated soil and land clearing debris (100% reuse or recycle) <br />28 <br />5.410.1 <br />Recycling by Occupants (recycling paper, corrugated cardboard, glass, plastics and metals). Applies to Additions > <br />30% increase in floor space within 12 month period. <br />29 <br />5.410.2 <br />Commissioning (> 10,000 SF) <br />30 <br />5.410.2.1 <br />- Owner's or Owner representative's Project Requirements (OPR) <br />31 <br />5.410.2.2 <br />- Basis of Design (BOD) <br />32 <br />5.410.2.3 <br />- Commissioning Plan <br />33 <br />5.410.2.4 <br />- Functional Performance Testing <br />34 <br />5.410.2.5 <br />- Documentation and Training Systems Manual & Systems Operation Training) <br />35 <br />5.410.2.6 <br />- Commissioning Report <br />36 <br />5.410.4 <br />Testing and Adjusting for (N) buildings < 10,000 SF or (N) systems that serve additions or alterations. <br />37 <br />5.410.4.2 <br />- System Testing Plan for HVAC, Lighting, water heating, renewable energy, landscape irrigation and water reuse <br />38 <br />5.410.4.3 <br />- Procedures for HVAC Balancing <br />39 <br />5.410.4.4 <br />- Reporting <br />40 <br />5.410.4.5 <br />- Operation and Maintenance O&M Manual <br />41 <br />5.410.4.5.1 <br />- Inspection and Reports <br />ENVIRONMENTAL QUALITY <br />42 <br />5.503 <br />Fireplaces and Woodstoves <br />43 <br />5.504.1.3 <br />Temporary Ventilation (MERV 8) <br />44 <br />5.504.3 <br />Covering of duct openings and protection of mechanical equipment during construction <br />45 <br />5.504.4.1 <br />Adhesives, sealants and caulks - VOC Limits Table 5.504.4.2 <br />46 <br />5.504.4.3 <br />Paints and Coatings - VOC Limits able 5.504.4.2 <br />47 <br />5.504.4.3.2 <br />Verification <br />48 <br />5.504.4.4 <br />Carpet Systems <br />49 <br />5.504.4.4.1 <br />Carpet Cushion <br />50 <br />5.504.4.4.2 <br />Carpet Adhesive <br />51 <br />5.504.4.5 <br />Composite Wood Products - Formaldehyde Limits (Table 5.504.4.5) <br />52 <br />5.504.4.5.3 <br />Documentation <br />53 <br />5.504.4.6 <br />Resilient Flooring system 80% <br />54 <br />5.504.4.6.1 <br />Verification of compliance <br />55 <br />5.504.5.3 <br />Filters (MERV 8) <br />56 <br />5.504.7 <br />Environmental Tobacco Smoke (ETS) Control <br />57 <br />5.505.1 <br />Indoor Moisture Control <br />58 <br />5.506.1 <br />Outside Air Delivery - for Indoor Air Quality (IAQ) <br />59 <br />5.506.2 <br />Carbon Dioxide (CO2) Monitoring - for buildings or additions <br />60 <br />5.507.4 <br />Acoustical Control - STC Values per ASTM E90 <br />61 <br />5.507.4.1.1 <br />Exterior Noise Transmission, Prescriptive Method <br />62 <br />5.507.4.1 <br />- Exterior noise transmission for walls and roof -ceiling (50 STC, or 40 01TC <br />63 <br />5.507.4.1 <br />- Exterior noise transmission for windows (40 STC, or 30 OITC <br />64 <br />5.507.4.2 <br />Performance Method <br />65 <br />5.507.4.3 <br />Interior sound transmission (wall and ceiling separating tenants to be 40 STC) <br />66 <br />5.508.1 <br />Ozone Depletion and Greenhouse reductions - For Outdoor Air Quality <br />67 <br />5.508.1.1 <br />- Chlorofluorocarbons CFCs for HVAC, refrigeration, and fire suppression w/o CFO's <br />68 <br />5.508.1.2 <br />- Halons for HVAC, refrigeration, and fire suppression w/o Halons <br />69 <br />5.508.2 <br />Supermarket Refrigerant Leak Reduction (As Applicable for > 8,000 s.f. (N) & Relocated Systems) <br />70 <br />5.508.2.1 <br />- Refrigerant Piping <br />71 <br />5.508.2.2 <br />- Refrigerant Piping Valves <br />72 <br />5.508.2.2.2 <br />- Refrigerant Piping Access Valves <br />73 <br />5.508.2.3 <br />- Refrigerated Service Case <br />74 <br />5.508.2.4 <br />- Refrigerant Receivers <br />75 <br />5.508.2.5 <br />- Pressure Testing <br />76 <br />5.508.2.6 <br />- Evacuation after Pressure Testing <br />MAND 7 Measures <br />REVISIONS BY <br />RELEASED DATE <br />11-08-2018 1 ST SUBMITTAL <br />ARC <br />yz� <br />/LARRY L. WANG <br />C-31807 <br />RENEWAL 11312 <br />OF C �� <br />SHEET CONTENTS: <br />CALGREEN NOTES <br />1850C Bakery Cafe <br />85 BAKERY STOCKTON <br />875 W. BENJAMIN HOLT DR., <br />STOCKTON, CA 95207 <br />DRAWN: <br />E.C. <br />CHECKED: <br />L.W. <br />DATE STARTED: <br />2018.08.29 <br />JOB NO.: <br />SCALE: <br />AS NOTED <br />FILE NAME: <br />SHEET NO.: <br />Al A <br />A. PRODUCT CERTIFICATIONS AND SPECIFICATIONS <br />B. CHAIN OF CUSTODY CERTIFICATIONS <br />C. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD PRODUCTS <br />REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.) APPROVAL STAMP: <br />D. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS -1 OR PS -2 STANDARDS OF THE <br />ENGINEERED WOOD ASSOCIATION, THE AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S STANDARDS. <br />E. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. <br />14. FOR 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING, INSTALLED RESILIENT FLOORING SHALL <br />MEET AT LEAST ONE OF THE FOLLOWING: <br />A. CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOOR SCORE <br />PROGRAM; <br />B. COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE <br />CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S 2010 STANDARD METHOD FOR THE TESTING AND <br />EVALUATION CHAMBERS, VERSION 1.1, FEBRUARY 2010; <br />C. COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS <br />(CA-CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012, AND LISTED IN THE CHPS HIGH <br />PERFORMANCE PRODUCT DATABASE; OR <br />D. COMPLIANT WITH CDPH CRITERIA AS CERTIFIED UNDER THE GREENGUARD CHILDREN'S & <br />SCHOOL PROGRAM. <br />