Laserfiche WebLink
0 <br />W <br />> <br />LU <br />C0 <br />LU <br />IY <br />U) <br />C� <br />iY <br />J <br />J <br />Q <br />u <br />1. GENERAL INSTALLATION POLICY INFORMATION <br />The policy contained herein describes specific policy information and purchaser requirements for underground <br />wastewater precast concrete tanks and structures (hereon referred as TANK, including grease interceptors, sand -oil <br />interceptors, sand traps, stormwater interceptors, septic tanks, clarifiers and holding tanks. Other Jensen Precast <br />company policies, including shipping, terms and conditions, ordering instructions, and others also apply. Contact <br />Jensen Precast for complete information. <br />In general, Jensen Precast provides delivery and setting of the TANK and sealing of the TANK in accordance with <br />the provisions of this policy. In a situation where our truck cranes cannot set the TANK for whatever reason, we will <br />provide a representative to supervise in the proper setting of the TANK and then seal the primary components as <br />specified herein. <br />Jensen Precast accepts responsibility for proper setting, assembly, and sealing of the TANK when installed or <br />supervised by Jensen Precast or an authorized representative. A TANK handled, moved, or installed without Jensen <br />Precast supervision, could nullify Jensen Precast's responsibility of warranty. <br />NOTE: Failure to follow proper TANK installation and or sealing procedures may result in structural <br />damage to the system or compromise its functional design along with nullifying product warranties. <br />2. EXCAVATION AND SITE PREPARATION <br />The TANK must be set on a properly prepared base to ensure against movement of either the TANK or the inlet and <br />outlet lines. The excavation shall be the proper width and length to accept the model selected and shall have enough <br />extra width and length to allow for safe installation and sealing of the components. Suitable native soil or sub -base <br />shall be prepared to handle anticipated loads. The excavation shall be bedded with suitable granular material and <br />shall be compacted to 90% of it's maximum dry density in accordance with ASTM D 1557 or to the requirements of <br />the project geotechnical engineer. The bottom of the excavation shall be graded level. <br />The area around the tank must be cleared to a minimum of 2' around the tank and 3' around any joint to be sealed. <br />The excavation's slope, benching or shoring shall comply with the requirements of OSHA 29 CFR 1926 Subpart P. <br />Jensen Precast will not violate this OSHA standard in the coarse of setting and sealing the TANK. <br />On battery TANK systems (multible-tanks joined together) with capacities in excess of 5,000 gallons, redwood <br />grade boards shall be used to ensure a level and stable tank joint. A minimum of two 2" x 6" grade boards, laid flat, <br />running the full length of the entire TANK assembly directly under the outside walls shall be used. The top of the <br />compacted fill material shall match the top of redwood grade boards prior to setting the TANK. A stringline or other <br />suitable means for aligning tanks shall be provided amd in place prior to installation. <br />The owner, customer, contractor, or others shall be responsible for the following: <br />1. Two workers or laborers to direct and assist the setting of, and location of the TANK. <br />2. Providing a properly prepared, sized, compacted base and graded excavation. <br />3. Supplying and installing redwood grade boards under battery TANK. <br />4. Providing job site safety, excavating safety, shoring as required, water and or flotation control. <br />5. Completing the entire installation and all other site work not specified herein. <br />3. SETTING AND INSTALLATION <br />Jensen Precast requires assistance from the customer or contractor in setting, sealing, and placing the TANK La <br />minimum of two workers is reauiredl. Access and setting location for our boom truck or other equipment must be <br />acceptable to our driver or representative. Tanks 2000 gallons and larger require extreme caution due to the weight <br />of the product. There may be situations where an outside crane may be needed to set the product. Contact Jensen <br />Precast for details. <br />Since site conditions, products, and delivery equipment vary tremendously, the logistics must be carefully <br />considered to determine the best possible approach for delivery and setting, including but not limited to: <br />MANUFACTURER OF PRECAST CONCRETE PRODUCTS 3 <br />Tank Installation Procedures - rev012010.doc <br />1200 GALLON <br />GREASE INTERCEPTOR <br />MODEL JP1200ECE-G <br />LISTED BY UPC® <br />NAPA AND PLACER COUNTY, <br />CITY OF ROSEVILLE <br />8'-6" <br />I II I <br />I II I <br />I II I <br />I 6'-0" <br />I 5 -g <br />I II I <br />I II I <br />I II I <br />L ---------J L_---_1 <br />1 <br />TOP VIEW <br />LIFTING LOOP <br />(COVERS &RINGS REMOVED) <br />24" CAST IRON FRAMES AND COVERS <br />WITH GASKET (GASTIGHT) 3 TOTAL <br />3", 6" AND 12" <br />GR2432 GRADE RINGS <br />~fAS REQUIRED <br />2'-6" TO 7'-6" a .. a' a' AT EXTRA COST <br />OUTLET <br />INVERT <br />6'-6" <br />OPERATING CAPACITY: 1,200 GALLONS. SIDE SECTION VIEW <br />DESIGN LOAD: H-20 TRAFFIC WITH DRY SOIL CONDITIONS <br />(WATER LEVEL BELOW TANK) AND 1'-6' EARTH COVER. <br />SUITABLE SUB -BASE BEDDED WITH GRANULAR MATERIAL SHALL BE <br />PREPARED TO HANDLE ANTICIPATED LOADS. <br />FOR COMPLETE DESIGN AND PRODUCT INFORMATION <br />CONTACT JENSEN PRECAST. <br />Jensen Precast reserves the right to make changes to product design <br />7/2/07 and/or dimensions without notice. Please contact Jensen Precast <br />J 007 Jensen <br />Pre P_A.dwg whenever necessary for confirmation or advice on product design. <br />m 2007 Jensen Precost <br />MINIMUM EXCAVATION <br />7'-0" x 9'-6" <br />x REQ'D DEPTH <br />p: f 7.1w 17 <br />AW PRECAST <br />1. The capacity of the crane, whether it's a Jensen Precast truck crane or contractor's crane to be used. <br />2. The maximum product weight relative to the setting distance from the center of the crane to the center of <br />the excavation which cannot exceed our truck crane's rated capacity and setback distance from the <br />excavation. <br />3. The type of terrain, site slope, and ground conditions for outrigger footing. <br />4. The access route for boom truck or other equipment. <br />5. The overhead restrictions (power lines, trees etc) and other physical constraints. <br />ANY of the above could prevent Jensen Precast from setting the TANK. <br />NOTE: If for any reason Jensen Precast cannot set the TANK, Jensen Precast will not be responsible or <br />charged for setting by any other means. <br />Check that the tank is level while connected to the crane. <br />The owner, customer, contractor, or others shall be responsible for the following: <br />1. Finished grading, leveling and positioning of TANK, and access openings. <br />2. Grouting, sealing, setting and adjusting of grade rings, risers, frames, covers, and all other hardware and <br />appurtenances. <br />3. Supplying and installing inlet and outlet pipes. <br />4. Sealing above the top of the TANK. <br />5. Any and all permits, licenses, tests, or approvals from any administrative authority that are required for <br />installation of the TANK. <br />4. VENTILATION <br />The TANK is equiped with inlet & outlet tee's which allow gases to escape the TANK atmosphere into the building <br />plumbing / ventilation system as prescribed by the Uniform Plumbing Code (UPC) unless local regulations <br />supercede. Failure to provide proper ventilation for the TANK could result in an odor problem. Please consult the <br />Uniform Plumbing Code and/or local regualtions for additional information. If additional venting requirements are <br />required, contact Jensen Precast. <br />5. TANK SEALING (BATTERY TANKS AND TANKS WITH HORIZONAL SEAMS) <br />For installation of sectional TANKS requiring job site joint sealing, Jensen Precast will seal the TANK only. The <br />owner, customer, or contractor shall be responsible for sealing or grouting of grade rings, risers, covers, inlets and <br />outlets if required. The TANK must be dry in order for the sealant to bond properly to the concrete. The sealant <br />must completly cure according to the time table below before conduction a water -tight testing. <br />Type of Water Test <br />Ambient Temperature Cure Time hours <br />To Operation Level <br />Greater Than 70' F 24 <br />Less Than 70' F 48 <br />To Top of Tank <br />All 72 <br />Failure to follow these guidelines or not allowing for a full cure of the joint sealant could cause the TANK to fail <br />water testing and possibly void Jensen Precast responsibility and product warranty. <br />6. BACKFILLING <br />Failure to comply with proper backfill procedures could result in structural damage or leakage from pipe <br />connections, or leakage from the TANK, due to settling, point loading, impacting, etc. Backfill shall be suitable <br />clean material and shall be laid in lifts limited to 24" and adequately compacted from bottom to top to prevent <br />movement or settling under the pipe or fittings. Only mechanical backfilling methods can be utilized; water - <br />jetting (liquification of backfill dirt) is not acceptable and could damge the TANK. <br />MANUFACTURER OF PRECAST CONCRETE PRODUCTS 4 <br />Tank Installation Procedures - rev012010.doc <br />GRADE RINGS/RISERS <br />MODEL 2432 <br />24" I.D., 4" WALL <br />CAUTION: High slump or flowable backfill like cement slurries must not be laid in lifts greater than 24" and <br />must be allowed to set up before the next lift is laid. It is recommended that before using flowable backfills, <br />contact Jensen Precast to discuss procedures for your application. <br />7. WATERTIGHT TESTING OVERVIEW <br />When watertight testing is required during inspection, testing must be completed and approved after installation, but <br />before the tank is put into service. Testing for watertighness shall be performed using either hydrostatic water test or <br />vacuum test per ASTM C1227-09 section 9 or ASTM C1613 section 9. Standard water test are conducted up to the <br />outlet of the tank per ASTM. Although ASTM does not address infiltration tests for tanks equipped with top slabs, if <br />required they are conducted up to the top of the top of slab following ASTM procedures. <br />Warning: Water tests conducted above the lid of the tank may have structrual implications and could exceed <br />the structural design of the tank. Contact Jensen Precast for complete details. <br />TANK with capacities of 2000 gallons or greater have specific backfill requirements before water testing. See <br />section 10. <br />The owner, customer, contractor, or others shall be solely responsible for the following: <br />1. Conducting and approval of the test. <br />2. Providing water and means to pump or evacuate water for testing or any subsequent retesting. <br />3. Providing the vaccum pump, seals for access opening and pipe plugs. <br />4. Sealing or testing grade rings, risers, covers, other openings, etc. <br />5. Any required sealing and testing of inlet and outlet pipelines. <br />8. PRE-TEST INSPECTION <br />Before any applicable tests are performed and before the TANK is placed into service, a visual inspection is to be <br />performed to insure that the TANK is free of trash and debris that could prevent the TANK from functioning <br />properly. All foreign objects such as rocks, trash, tools, or construction materials left inside the TANK from the <br />installation process should be removed and properly disposed. Check that the tank is level. <br />Check that the inlet and outlet pipe are properly connected and sealed to the tank. Check the tank inlet, baffle and <br />outlet have the appropiate pipe fitting attached and have no obstructions. <br />9. WATER TESTING TANKS UP TO 1500 GALLONS <br />The TANK shall be filled to the operational liquid level (outlet invert) with water and allowed to stand to achieve <br />complete concrete absorption, then refilled to the same level. Once refilled, there shall be no measurable liquid loss <br />in the following hour. (Ref. ASTM C-1227-07 9.2.2) <br />10. WATER TESTING TANKS 2000 GALLONS AND GREATER <br />All TANKS of 2000 gallon capacity or greater and all battery TANKS must be backfilled to the outlet pipe when <br />water testing. Warning: Water testing tanks with a liquid capacity of 2000 gallons or greater without <br />backfilling could damage the tank. The TANK shall be filled to the operational liquid level with water and <br />allowed to stand to achieve complete concrete absorption, then refilled to the same level. Once refilled, there shall <br />be no measurable liquid loss in the following hour. (Ref. ASTM C-1227-07 9.2.2) <br />If the Administractive Authority requires visusal inspection of the exterior walls during the water test, then use the <br />following procedures. <br />SINGLE TANK UNITS: Backfilling in increments can accomplish an exterior wall inspection when done in 2 foot <br />lifts. To begin introduce, 2 feet of water in the bottom of the TANK. Once inspected, backfill and compact 2 feet of <br />the outside walls, after compaction add an additional 2 feet of water into the tank. Inspect the outside walls as <br />previously done and repeat these procedures until completely inspected and backfilled. <br />MANUFACTURER OF PRECAST CONCRETE PRODUCTS 5 <br />Tank Installation Procedures - rev012010.doc <br />TRENCH STRUCTURAL DETAIL'I <br />SECTION A -A <br />1 <br />12" <br />DESCRIPTION <br />APPROX. <br />WEIGHT <br />2432 GR -03 GRADE RING <br />92 LBS. <br />2432 GR -06 GRADE RING <br />183 LBS. <br />2432 GR -12 GRADE RING <br />366 LBS. <br />CONFORMS TO CURRENT SPECIFICATIONS: <br />ASTM C-478 AND AASHTO M-199 <br />HAUNCHING <br />4" MIN BEDDING <br />IF WATER OR SOFT GROUND IS PRESEN <br />9" MIN PLACE COARSE BEDDING MATERIAL IN <br />GEOTEXTILE WRAP WITH 12" MIN <br />❑VERLAP @ FABRIC EDGES <br />CZ PIPE & TRENCH <br />NOTES: <br />1. TRENCH WIDTH, PIPE BEDDING & BACKFILL SHALL CONFORM TO THE <br />APPLICABLE REOUIREMENTS AND PROVISIONS OF SECTION <br />15.02205 OF THESE SPECIFICATIONS. <br />2. THESE AREM[N[MUM REQUIREMENTS- IF OTHER JURISDICTIONAL <br />AGENCY REQUIREMENTS EXCEED THOSE SHOWN, THE GREATER <br />REQUIREMENTS SHALL BE MET. <br />3. 1007 AE REQUIRED FOR SIDEWALK OR DRIVEWAY. <br />COMMERCIAL TANK <br />EXCAVATION AND SITE PREPARATION <br />-1F -1F__ __1 <br />L L <br />I I <br />(D 0 <br />1 <br />I n 1 n I <br />L-- J L 1 J I - --J <br />2' MINIMUM (NOTE 1 ) <br />PLAN VIEW <br />(COVERS & RISERS REMOVED) <br />FINISHED <br />ASE <br />OTES <br />ND 4) <br />EXCAVATION <br />(NOTES 1 AND 2) <br />1 BASE,...,...,...,..., <br />SIDE ELEVATION END ELEVATION <br />NOTES: SECTION SECTION <br />1. AREA MUST BE PREPARED AND CLEARED TO 2 FEET MINIMUM SURROUNDING ENTIRE TANK. <br />2. THE EXCAVATION'S SLOPE, BENCHING OR SHORING SHALL COMPLY WITH THE REQUIREMENTS OF <br />OSHA 29 CFR 1926 SUBPART P. JENSEN PRECAST WILL NOT VIOLATE THIS OSHA STANDARD IN THE <br />COURSE OF SETTING AND SEALING THE TANK. <br />3. BASE MUST BE LEVEL AND EVEN IN ALL DIRECTIONS. <br />4. THE EXCAVATION SHALL BE BEDDED WITH SUITABLE GRANULAR MATERIAL AND SHALL BE <br />COMPACTED TO 90% OF IT'S MAXIMUM DRY DENSITY OR TO THE REQUIREMENTS OF THE PROJECT <br />GEOTECHNICAL ENGINEER. <br />DRAWING NOT TO SCALE ���Jensen Precost reserves the right to moke chonges to product designand or dimensions without notice. Please contact Jensen Precast whenever/n r f r nfirm tin r vi n r t i n.ecesso o co 0 0 0 od ce o oduc des JEf <br />RECAST <br />12/31/2009 Y P 9 <br />COMMERCIAL TANK SITE PREP_A.DWG <br />02009 <br />TRENCH STRUCTURAL DETAIL 2 <br />TRENCH SECTION IN UNPAVED AREAS <br />(OFF ROAD EASEMENT OR FUTURE STREETS) <br />TRENCH WIDTH <br />{SEE NOTE 11 <br />BENCHED OR <br />SLOPED TRENCH \ <br />PER <br />REQUIREMENTS <br />WARNING TAPE <br />PER REQUIREMENTS OF <br />SECTION 15,02205. <br />HZ PIPE & TRENCH <br />� Y <br />/Q TRENCH <br />m ZONE <br />RELATIVE ATIVE <br />w COMPACTION <br />J <br />} <br />H <br />J <br />SHADING LL PIPE <br />< ZONE <br />90% <br />RELATIVE <br />w COMPACTION <br />HAUNCHING } <br />BEDDING <br />IF WATER OR SOFT GROUND <br />15 PRESENT, PLACE COARSE <br />BEDDING MATERIAL [N <br />GEOTEXTILE WRAP WITH 12" <br />MIN OVERLAP @ FABRIC EDGES <br />NaTFS- <br />1. TRENCH WIDTH. PIPE BEDDING & BACKFILL SHALL CONFORM TO <br />THE APPLICABLE REQUIREMENTS AND PROVISIONS OF SECTION <br />15.02205 OF THESE SPECIFICATIONS. <br />2. THESE ARE MINIMUM REQUIREMENTS. IF OTHER JURISDICTIONAL <br />AGENCY REQUIREMENTS EXCEED THOSE SHOWN, THE GREATER <br />REQUIREMENTS SHALL BE MET. <br />GREASE INTERCEPTOR INSTALLATION DETAIL AND SPECIFICATION <br />SCALE: NTS <br />STANDARD TRUNK SEWER TRENCH DETAILS <br />FOR 12" AND LARGER PIPE <br />EXISTING GROUND OR <br />PAVEMENT SUB -GRADE <br />EXISTING GROUND OR <br />PAVEMENT SUE -GRADE <br />TRENCH WIDTH TRENCH WIDTH <br />BACKFILL SEE BACKFILL SEE <br />DWG -14 a 15 DWc-14 & 15 <br />r+ TYPE [ <br />-TYPE <br />! <br />O 1/3 1). D. <br />.D. IF WATER OR SOFTS j '' <br />91. GROUND IS PRESENT, �� 9` <br />PLACE COARSE BEDDING MIN. <br />MATERIAL IN <br />GEOTEXTILE WRAP <br />WITH 12" MIN. OVERLAP <br />@ FABRIC EDGES. <br />FOR R.C. AND STEEL PIPE FOR R.C. PIPE <br />INSTALLATIONS INSTALLATIONS <br />UP TO 42" 48" AND LARGER <br />(N.T.S.) (N.T.S.) <br />NOTES: 1. PIPE BEDDING AND BACKFILL SHALL CONFORM TO THE REQUIREMENTS OF SECTION 15.02205. <br />2. WARNING TAPE REQUIRED AT TOP OF THE PIPE ZONE. <br />E=1 1 ni earn, ni <br />aJJJ �! �e�sjlJJ <br />Z4 <br />S earw cJ0�s� I n1 cJ <br />.JJ J.�JJJ.�J <br />ADR: 3119 Central Parkway, <br />Dublin CA. 94568 <br />TEL: 510-788-6029 <br />CEL: 510-468-0613 <br />FAX: 510-788-6039 <br />Revisions Date <br />PROGRESS REVIEW 10-01-2018 <br />PERMIT SET 10-29-2018 <br />Preliminary Set <br />Design Review Set <br />Plan Check Set X <br />Plan Check Resubmit <br />Construction Set <br />1 <br />L.L <br />C) <br />J <br />O <br />CZ <br />G <br />W <br />co <br />LO <br />r" <br />CO <br />C) <br />N <br />LO0 <br />Q <br />U <br />Z <br />O <br />U <br />O <br />0 <br />Scale: AS NOTED <br />Drawn By: AL <br />Approved By: JP <br />Job: 18033 <br />Sheet <br />PLUMBING <br />DETAILS <br />TRENCH WIDTH <br />� TRENCH WIDTH <br />/ <br />'4j <br />BACKFILL SEE <br />DWG -14 & 15 <br />%i <br />L` <br />a <br />v <br />o <br />� <br />92 <br />fl <br />W <br />J <br />TYPE I <br />U <br />BACKFILL <br />CD <br />y co <br />9"MIN <br />q�T <br />IF WATER OR SOFT <br />g"MIN <br />EXCAVATE <br />GROUND Is PRESENT, <br />FOR <br />PLACE COARSE BEDDING <br />BELL ENDS <br />MATERIAL IN <br />GEOTEXTILE WRAP <br />WITH 12" MIN. OVERLAP <br />@ FABRIC EDGES. <br />FOR D.I. PIPE <br />FOR ALL V.C., <br />P.V.C. <br />INSTALLATIONS ONLY <br />PIPE INSTALLATIONS <br />(N.T.S.) <br />(N.T.S.) <br />EXISTING GROUND OR <br />PAVEMENT SUE -GRADE <br />TRENCH WIDTH TRENCH WIDTH <br />BACKFILL SEE BACKFILL SEE <br />DWG -14 a 15 DWc-14 & 15 <br />r+ TYPE [ <br />-TYPE <br />! <br />O 1/3 1). D. <br />.D. IF WATER OR SOFTS j '' <br />91. GROUND IS PRESENT, �� 9` <br />PLACE COARSE BEDDING MIN. <br />MATERIAL IN <br />GEOTEXTILE WRAP <br />WITH 12" MIN. OVERLAP <br />@ FABRIC EDGES. <br />FOR R.C. AND STEEL PIPE FOR R.C. PIPE <br />INSTALLATIONS INSTALLATIONS <br />UP TO 42" 48" AND LARGER <br />(N.T.S.) (N.T.S.) <br />NOTES: 1. PIPE BEDDING AND BACKFILL SHALL CONFORM TO THE REQUIREMENTS OF SECTION 15.02205. <br />2. WARNING TAPE REQUIRED AT TOP OF THE PIPE ZONE. <br />E=1 1 ni earn, ni <br />aJJJ �! �e�sjlJJ <br />Z4 <br />S earw cJ0�s� I n1 cJ <br />.JJ J.�JJJ.�J <br />ADR: 3119 Central Parkway, <br />Dublin CA. 94568 <br />TEL: 510-788-6029 <br />CEL: 510-468-0613 <br />FAX: 510-788-6039 <br />Revisions Date <br />PROGRESS REVIEW 10-01-2018 <br />PERMIT SET 10-29-2018 <br />Preliminary Set <br />Design Review Set <br />Plan Check Set X <br />Plan Check Resubmit <br />Construction Set <br />1 <br />L.L <br />C) <br />J <br />O <br />CZ <br />G <br />W <br />co <br />LO <br />r" <br />CO <br />C) <br />N <br />LO0 <br />Q <br />U <br />Z <br />O <br />U <br />O <br />0 <br />Scale: AS NOTED <br />Drawn By: AL <br />Approved By: JP <br />Job: 18033 <br />Sheet <br />PLUMBING <br />DETAILS <br />