Laserfiche WebLink
0 <br />Lu <br />> <br />w <br />co <br />Lu <br />ry <br />U) <br />c� <br />it <br />J <br />J <br />Q <br />U <br />Z <br />C6 <br />Lu <br />U <br />ry <br />Lu <br />U) <br />z <br />0 <br />U) <br />w <br />0 <br />0 <br />z <br />Q <br />0 <br />z <br />w <br />w <br />z <br />z <br />Lu <br />d <br />ATTACHMENT TO <br />STRUCTURE WITH <br />SPECIFIED ANCHOR <br />OR INSERTS <br />SPECIFIED — <br />TRANSVERSE <br />BRACE <br />PIPE RACK UNSTRUT <br />P-5500 60"MAX.SPAN <br />BETWEEN HANGER RODS <br />PECIFIED HANGER ROD <br />SPECIFIED LONGITUDINAL BRACE <br />IPE CLAMP 10 GA <br />STRAP OR U—BOLT <br />SPECIFIED PIPE <br />SHIELD FOR <br />INSULATED PIPE <br />SPECIFIED <br />HANGER ROD <br />AND BRACING <br />SPECIFIED <br />PIPE <br />HANGER <br />PIPE <br />SIZE <br />HANGER <br />ROD SIZE <br />MAX. WEIGHT PER <br />HANGER LOAD <br />MAXIMUM PIPE SUPPORT SPACING <br />COPPER TUBE <br />OR PIPE <br />STEEL PIPE <br />CAST—IRON <br />" <br />2-1 <br />$ <br />TEST <br />6'-0" <br />6'-0" <br />EVERY OTHER JOINT, <br />UNLESS OVER 4' THEN <br />SUPPORT EACH JOINT <br />2'-3" <br />2" <br />730 LBS <br />" <br />10'-0 <br />10'-0" <br />>= 4" <br />$" <br />810 LBS <br />10'-0" <br />10'-0" <br />NOTES: <br />1. SUPPORT PIPES AT INTERVALS INDICATED AND AT EACH CHANGE OF DIRECTION. <br />2. MULTIPLE PIPES MAY BE SUPPORTED ON A COMMON TRAPEZE SIZE AND SPACING <br />TRAPEZE SIZE AND SUPPORT SPACING SHALL BE GOVERNED BY CUMULATIVE WEIGHT OF <br />SUPPORTED PIPING. <br />3. BRACE PIPING LONGITUDINALLY AND TRANSVERSELY ACCORDING TO SMACNA GUIDELINES <br />FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEM AND PLUMBING PIPING SYSTEM <br />4. ALL PIPE HANGER AND SUPPORT SHALL CONFORM TO 2016 CPC TABLE 313.6 AND 313.1 <br />� PIPE SUPPORT DETAIL <br />SCALE: N.T.S. <br />METALLIC PIPE WOOD JOIST <br />FLOOR—CEILING <br />ASSEMBLY <br />FIRESTOP <br />SEALANT <br />�1 <br />41. WTI WTI 0 1 <br />1001 <br />- <br />PIPE PENETRATES <br />4 DATED EL./CLG. DETAIL <br />SCALE: N.T.S. <br />FLUSH WITH <br />CEILING <br />WATTS # <br />007M2QT—S <br />OR <br />EQUIVALENT <br />3/4" <br />DOUBLE CHECK <br />ICE <br />VALVE WITH <br />TEST <br />COCKS AND <br />EXPANSION TAN <br />STRAINER IN <br />HORIZ— <br />ONTAL ORIENTATION. <br />3/4"0 CONNECTIONS <br />TO FILTERS WITH <br />BALL VALVE AND <br />UNION DIELECTRIC <br />WATER HEATER TYPE—B <br />LISTED DOUBLE WALL <br />FLUE AND DRAFT HOOD <br />BY MECH. <br />HWR <br />r <br />O1 RECIRIC ULATO <br />CW <br />3/4" COLD WATER <br />ROUGH—IN WITH <br />BALL VALVE AND SOFT—COLD WA <br />UNION SUPPLY TO WA' <br />APPROXIMATELY HEATER <br />7'-3" ABOVE <br />FLOOR PIPE UNION: <br />EXPANSION <br />TANK <br />TO DRAIN - <br />5/8" HILTI TZ BOLT <br />WITH MIN. 3%2 <br />EMBT. TYP. OF 2. <br />SEAL DRAIN PAN <br />WATERTIGHT <br />DRAIN PAN <br />MIN. 12" <br />WATER HEATE <br />SCALE: N.T.S. <br />NOTE: <br />U HOT WATER <br />HWS RECIRCULATOR SHALL <br />BE CONTROLLED BY <br />HWS BUILT-IN TIME CLOCK <br />AND AQUASTAT. <br />-SHUT-OFF VALVE <br />LEXIBLE CONNECTION <br />-DIELECTRIC UNION <br />METAL STRAP, BOLT TO <br />WALL BRACING WITH 2 #14 <br />METAL SCREW AT EACH <br />CONNECTION <br />-­ASME T&P RELIEF <br />---BACKING PLATE AT STUD <br />WALL FOR CONNECTION <br />3/4"0 DRAIN FROM <br />T&P PIPED TO <br />NEAR—BY MOB SINK <br />3/49'0 DRAIN FROM <br />DRAIN PAN PIPED <br />TO NEAR—BY MOB <br />SINK <br />1 " OR 2X PIPE <br />DIAMETER <br />FLOOR SINK <br />R MOUNTING AND PIPING DETAIL <br />PIPE HANGER <br />NEXT TO PIPE TEE <br />1%2"O SOFT WATER <br />FROM WATER SOFTENER <br />"INVERTA—COLLAR"(SHOWN <br />SHUT—OFF VALVE IN ulr_u POCITIONI <br />WATTS NO. 530 <br />1/2" CALIBRATED <br />PRESSURE <br />RELIEF VALVE <br />SET AT 100 PSI. <br />HARD COPPER RELIEF <br />VALVE INDIRECTLY <br />' 00 AIR CHARGING VALVE. DISCHARGE TO <br />IF REQUIRED FOR FLOOR MOP SINK AT <br />DISSIMILAR METALS. WATER FILTERS FILL TANK WITH AIR 2" ABOVE FLOOD <br />PROVIDED BY PRESSURE TO MATCH <br />IAI A TrM Arlt l lmY . RIM. <br />WALL BEHIND U I HE S, MUUN I tU vvH I F- 1\ r-rCLJJUrCL, <br />ICE MACHINE ON WALL BESIDE THEN OPEN VALVE. <br />ICE MACHINE. NOTES: <br />FLOOR UNIT SHALL BE FDA APPROVED FOR DOMESTIC WATER USE. PIPING <br />ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD <br />NOTES: CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW <br />MAKE CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURERS. MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. <br />VERIFY PROPER OPERATION WHEN INSTALLED. <br />WATER FILTERS AT <br />ICE MACHINE PIPING DETAIL <br />SCALE: N.T.S. <br />FLOOR SLAB <br />FINISHED GRADE <br />CUT—OFF FERRULE <br />FAND SCREW PLUG <br />CONCRETE BLOCK <br />°d a <br />PLUG WHERE C.O. <br />OCCURS AT END <br />OF LINE <br />FLOOR CLEAN OUT DETAIL <br />SCALE: N.T.S. <br />V NIT BASE RAIL <br />EVAPORATORTEE CONNECTION W/PLUG <br />/RTU <br />VENT <br />NDIRECT <br />DRAIN INTO <br />CONDENSATE <br />MIN. 3" DRAIN NEARBY <br />FLOOR SINK <br />MIN. 3" <br />CONDENSATE DRAIN <br />PIPING DETAIL <br />SCALE: N.T.S. <br />EXPANSION TANK PIPING DETAIL <br />SCALE: N.T.S. <br />PROVIDE 3/4" ROUGH—IN <br />AND PROVIDE FULL <br />PORT BALL SHUT—OFF <br />VALVE. <br />INSTALL WATER FILTERS <br />PER MANUFACTURER'S <br />INSTRUCTIONS. REFER <br />TO DETAIL 3 ON THIS <br />PAGE. <br />FLOOR DRA <br />SCALE: N.T.S. <br />3/4" COLD WATER <br />SUPPLY DOWN IN <br />PARTITION WHERE <br />SHOWN ON PLAN. <br />INISHED FLOOR <br />'ENEER <br />INISH FLOOR <br />SLAB <br />VATERPROOFING <br />MEMBRANE <br />ZOUGH <br />-LOOR SLAB <br />TRAP PRIMER <br />CONNECTION <br />SYSTEM NO.W-L-1003 SEPTEMBER 03, 2004 <br />(FORMERLY SYSTEM NO. 147) <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) - T RATING - 0 HR <br />1. WALL ASSEMBLY — THE 1 OR 2 HR FIRE—RATED GYPSUM WALLBOARD/STUD-WALL ASSEMBLY SHALL <br />BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR <br />U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE <br />THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS — WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. <br />WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. <br />LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-1/2 IN. WIDE BY 1-3/8 IN. <br />DEEP CHANNELS SPACED MAX 24 IN. OC. <br />B. GYPSUM BOARD* — NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE <br />GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION <br />SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE <br />RESISTANCE DIRECTORY. MAX DIAMETER OF OPENING IS 15 IN. <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE <br />WALL ASSEMBLY IN WHICH IT IS INSTALLED. <br />2. THROUGH PENETRANT — ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER <br />CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE SPACE BETWEEN PIPES, <br />CONDUITS OR TUBING AND THE STEEL SLEEVE (ITEM 3A) SHALL BE MIN OF 0 IN. (POINT CONTACT) TO <br />MAX 2-3/8 IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL <br />ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE <br />USED: <br />A. STEEL PIPE — NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE — NOM 12 IN. DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL <br />PIPE, NOM 12 IN. DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE. <br />C. CONDUIT — NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. DIAM (OR SMALLER) <br />STEEL ELECTRICAL METALLIC TUBING. <br />D. COPPER TUBING — NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />E. COPPER PIPE — NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />3. FIRESTOP SYSTEM — INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE DETAILS <br />OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS. <br />A. STEEL SLEEVE — CYLINDRICAL SLEEVE FABRICATED FROM MIN 0.019 IN. THICK (NO. 28 GAUGE) <br />GALV SHEET STEEL AND HAVING A MIN 2 IN. LAP ALONG THE LONGITUDINAL SEAM. LENGTH OF STEEL <br />SLEEVE TO BE EQUAL TO THICKNESS OF WALL PLUS 1 TO 4 IN. SUCH THAT, WHEN INSTALLED, THE <br />ENDS OF THE SLEEVE WILL PROJECT APPROXIMATELY 1/2 TO 2 IN. BEYOND THE SURFACE OF THE <br />WALL ON BOTH SIDES OF THE WALL ASSEMBLY. SLEEVE INSTALLED BY COILING THE SHEET STEEL TO <br />A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE OPENINGS AND <br />RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM WALLBOARD <br />LAYERS. <br />B. PACKING MATERIAL — MIN 1 IN. THICKNESS OF MINERAL WOOL BATT INSULATION FIRMLY <br />PACKED INTO STEEL SLEEVE ON BOTH SIDES OF THE WALL ASSEMBLY AS PERMANENT FORMS. PACKING <br />MATERIAL TO BE RECESSED MIN 1/2 IN. FROM END OF STEEL SLEEVE (FLUSH WITH OR RECESSED <br />INTO GYPSUM WALLBOARD SURFACE) ON BOTH SIDES OF WALL ASSEMBLY. <br />B1. PACKING MATERIAL — (NOT SHOWN) — AS AN ALTERNATE TO ITEM B, NOM 1 IN. THICK <br />POLYETHYLENE BACKER ROD MAY BE USED. THE BACKER ROD IS TO BE RECESSED WITHIN THE STEEL <br />SLEEVE A MIN OF 1 IN. FROM EACH SURFACE OF WALL. <br />C. FILL,VOID OR CAVITY MATERIALS* — CAULK OR SEALANT — WHEN MINERAL WOOL BATT <br />INSULATION IS USED, APPLIED TO FILL THE STEEL SLEEVE TO A MIN DEPTH OF 1/2 IN. ON BOTH <br />SIDES OF WALL ASSEMBLY. WHEN BACKER ROD IS USED, A MIN THICKNESS OF 1 IN. OF CP-25WB+ <br />CAULK IS REQUIRED FLUSH WITH SURFACE OF WALL. A NOM 1/4 IN. DIAM CONTINUOUS BEAD OF <br />CAULK OR SEALANT SHALL BE APPLIED AROUND THE CIRCUMFERENCE OF THE STEEL SLEEVE AT ITS <br />EGRESS FROM THE GYPSUM WALLBOARD LAYERS ON BOTH SIDES OF THE WALL ASSEMBLY. <br />K]b<KU51l_l.IQ9i�by5`I a�l_l�l�:t�l:a� II�1�I�I�1•'PI�9�_1�1.IM <br />*BEARING THE UL CLASSIFICATION MARKING <br />PIPE TH ICU DATED WALL DETAIL <br />SCALE: N.T.S. <br />COLD WATER <br />BRANCH LINE <br />TO CW WATER <br />IN DETAIL MAIN IN rFII INCA <br />/ ADAPTERS AND SOFT <br />COPPER TUBES SIZE OF <br />CUBER CONNECTION TO (2) <br />CUBER WATER INLETS. <br />CONNECT TO CUBERS <br />ICE BIN o AND ICE BIN DRAIN <br />OUTLETS AS REQ'D. <br />3/4" REFER TO "INDIRECT/ <br />CONDENSATE DRAIN" <br />FLOOR CO1 DETAIL FOR MORE <br />INFORMATION. <br />NOTES: FLOOR SINK <br />PROVIDE FLOOR SINK AT SIDE EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR CLEANING - NOT UNDER <br />ANY EQUIPMENT. PROVIDE COLD WATER ROUGH -IN AT TOP OF ICE MACHINES. ARRANGEMENT SHOWN IS <br />SCHEMATIC. ADJUST AS REQUIRED TO SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. <br />ICE MACHINE PIPING DETAILS <br />SCALE: N.T.S. <br />TRAP -PRIMER PIPING DETAIL <br />SCALE: N.T.S. <br />EJ�Jg JJ !D <br />P J117rjJJJ <br />SJe�rw cJe�s� Irn1 rm <br />ADR: 3119 Central Parkway, <br />Dublin CA. 94568 <br />TEL: 510-788-6029 <br />CEL: 510-468-0613 <br />FAX: 510-788-6039 <br />Revisions Date <br />PROGRESS REVIEW 10-01-2018 <br />PERMIT SET 10-29-2018 <br />Preliminary Set <br />Design Review Set <br />Plan Check Set X <br />Plan Check Resubmit <br />Construction Set <br />1 <br />W <br />z <br />� W <br />Qw <br />0 <br />m � <br />V � <br />oz <br />LOa <br />z <br />00 � <br />O. <br />O <br />J � <br />O d' <br />2 Q <br />Z U <br />2 <br />Q ZO <br />LLI <br />0o U <br />LO <br />00 Cn <br />Scale: AS NOTED <br />Drawn By: AL <br />Approved By: JP <br />Job: 18033 <br />Sheet <br />PLUMBING <br />DETAILS <br />of: <br />PB -0.3 <br />DIELECTRIC IF <br />%2" SOFT <br />COPPER <br />DISSIMILAR MET <br />TUBE TO <br />ICE <br />WELDED STEEL <br />MACHINE. <br />PROVIDE <br />EXPANSION TAN <br />ADAPTERS <br />AND <br />WITH POLYPRO— <br />FITTINGS AS <br />PYLENE LINING <br />REQUIRED <br />TO <br />CONNECT. <br />BUTYL DIAPHRA, <br />EXPANSION <br />TANK <br />TO DRAIN - <br />5/8" HILTI TZ BOLT <br />WITH MIN. 3%2 <br />EMBT. TYP. OF 2. <br />SEAL DRAIN PAN <br />WATERTIGHT <br />DRAIN PAN <br />MIN. 12" <br />WATER HEATE <br />SCALE: N.T.S. <br />NOTE: <br />U HOT WATER <br />HWS RECIRCULATOR SHALL <br />BE CONTROLLED BY <br />HWS BUILT-IN TIME CLOCK <br />AND AQUASTAT. <br />-SHUT-OFF VALVE <br />LEXIBLE CONNECTION <br />-DIELECTRIC UNION <br />METAL STRAP, BOLT TO <br />WALL BRACING WITH 2 #14 <br />METAL SCREW AT EACH <br />CONNECTION <br />-­ASME T&P RELIEF <br />---BACKING PLATE AT STUD <br />WALL FOR CONNECTION <br />3/4"0 DRAIN FROM <br />T&P PIPED TO <br />NEAR—BY MOB SINK <br />3/49'0 DRAIN FROM <br />DRAIN PAN PIPED <br />TO NEAR—BY MOB <br />SINK <br />1 " OR 2X PIPE <br />DIAMETER <br />FLOOR SINK <br />R MOUNTING AND PIPING DETAIL <br />PIPE HANGER <br />NEXT TO PIPE TEE <br />1%2"O SOFT WATER <br />FROM WATER SOFTENER <br />"INVERTA—COLLAR"(SHOWN <br />SHUT—OFF VALVE IN ulr_u POCITIONI <br />WATTS NO. 530 <br />1/2" CALIBRATED <br />PRESSURE <br />RELIEF VALVE <br />SET AT 100 PSI. <br />HARD COPPER RELIEF <br />VALVE INDIRECTLY <br />' 00 AIR CHARGING VALVE. DISCHARGE TO <br />IF REQUIRED FOR FLOOR MOP SINK AT <br />DISSIMILAR METALS. WATER FILTERS FILL TANK WITH AIR 2" ABOVE FLOOD <br />PROVIDED BY PRESSURE TO MATCH <br />IAI A TrM Arlt l lmY . RIM. <br />WALL BEHIND U I HE S, MUUN I tU vvH I F- 1\ r-rCLJJUrCL, <br />ICE MACHINE ON WALL BESIDE THEN OPEN VALVE. <br />ICE MACHINE. NOTES: <br />FLOOR UNIT SHALL BE FDA APPROVED FOR DOMESTIC WATER USE. PIPING <br />ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD <br />NOTES: CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW <br />MAKE CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURERS. MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. <br />VERIFY PROPER OPERATION WHEN INSTALLED. <br />WATER FILTERS AT <br />ICE MACHINE PIPING DETAIL <br />SCALE: N.T.S. <br />FLOOR SLAB <br />FINISHED GRADE <br />CUT—OFF FERRULE <br />FAND SCREW PLUG <br />CONCRETE BLOCK <br />°d a <br />PLUG WHERE C.O. <br />OCCURS AT END <br />OF LINE <br />FLOOR CLEAN OUT DETAIL <br />SCALE: N.T.S. <br />V NIT BASE RAIL <br />EVAPORATORTEE CONNECTION W/PLUG <br />/RTU <br />VENT <br />NDIRECT <br />DRAIN INTO <br />CONDENSATE <br />MIN. 3" DRAIN NEARBY <br />FLOOR SINK <br />MIN. 3" <br />CONDENSATE DRAIN <br />PIPING DETAIL <br />SCALE: N.T.S. <br />EXPANSION TANK PIPING DETAIL <br />SCALE: N.T.S. <br />PROVIDE 3/4" ROUGH—IN <br />AND PROVIDE FULL <br />PORT BALL SHUT—OFF <br />VALVE. <br />INSTALL WATER FILTERS <br />PER MANUFACTURER'S <br />INSTRUCTIONS. REFER <br />TO DETAIL 3 ON THIS <br />PAGE. <br />FLOOR DRA <br />SCALE: N.T.S. <br />3/4" COLD WATER <br />SUPPLY DOWN IN <br />PARTITION WHERE <br />SHOWN ON PLAN. <br />INISHED FLOOR <br />'ENEER <br />INISH FLOOR <br />SLAB <br />VATERPROOFING <br />MEMBRANE <br />ZOUGH <br />-LOOR SLAB <br />TRAP PRIMER <br />CONNECTION <br />SYSTEM NO.W-L-1003 SEPTEMBER 03, 2004 <br />(FORMERLY SYSTEM NO. 147) <br />F RATINGS - 1 AND 2 HR (SEE ITEM 1) - T RATING - 0 HR <br />1. WALL ASSEMBLY — THE 1 OR 2 HR FIRE—RATED GYPSUM WALLBOARD/STUD-WALL ASSEMBLY SHALL <br />BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR <br />U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE <br />THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS — WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. <br />WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. <br />LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-1/2 IN. WIDE BY 1-3/8 IN. <br />DEEP CHANNELS SPACED MAX 24 IN. OC. <br />B. GYPSUM BOARD* — NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE <br />GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION <br />SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE <br />RESISTANCE DIRECTORY. MAX DIAMETER OF OPENING IS 15 IN. <br />THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE <br />WALL ASSEMBLY IN WHICH IT IS INSTALLED. <br />2. THROUGH PENETRANT — ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER <br />CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE SPACE BETWEEN PIPES, <br />CONDUITS OR TUBING AND THE STEEL SLEEVE (ITEM 3A) SHALL BE MIN OF 0 IN. (POINT CONTACT) TO <br />MAX 2-3/8 IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL <br />ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE <br />USED: <br />A. STEEL PIPE — NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE — NOM 12 IN. DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL <br />PIPE, NOM 12 IN. DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE. <br />C. CONDUIT — NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. DIAM (OR SMALLER) <br />STEEL ELECTRICAL METALLIC TUBING. <br />D. COPPER TUBING — NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />E. COPPER PIPE — NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />3. FIRESTOP SYSTEM — INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE DETAILS <br />OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS. <br />A. STEEL SLEEVE — CYLINDRICAL SLEEVE FABRICATED FROM MIN 0.019 IN. THICK (NO. 28 GAUGE) <br />GALV SHEET STEEL AND HAVING A MIN 2 IN. LAP ALONG THE LONGITUDINAL SEAM. LENGTH OF STEEL <br />SLEEVE TO BE EQUAL TO THICKNESS OF WALL PLUS 1 TO 4 IN. SUCH THAT, WHEN INSTALLED, THE <br />ENDS OF THE SLEEVE WILL PROJECT APPROXIMATELY 1/2 TO 2 IN. BEYOND THE SURFACE OF THE <br />WALL ON BOTH SIDES OF THE WALL ASSEMBLY. SLEEVE INSTALLED BY COILING THE SHEET STEEL TO <br />A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE OPENINGS AND <br />RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM WALLBOARD <br />LAYERS. <br />B. PACKING MATERIAL — MIN 1 IN. THICKNESS OF MINERAL WOOL BATT INSULATION FIRMLY <br />PACKED INTO STEEL SLEEVE ON BOTH SIDES OF THE WALL ASSEMBLY AS PERMANENT FORMS. PACKING <br />MATERIAL TO BE RECESSED MIN 1/2 IN. FROM END OF STEEL SLEEVE (FLUSH WITH OR RECESSED <br />INTO GYPSUM WALLBOARD SURFACE) ON BOTH SIDES OF WALL ASSEMBLY. <br />B1. PACKING MATERIAL — (NOT SHOWN) — AS AN ALTERNATE TO ITEM B, NOM 1 IN. THICK <br />POLYETHYLENE BACKER ROD MAY BE USED. THE BACKER ROD IS TO BE RECESSED WITHIN THE STEEL <br />SLEEVE A MIN OF 1 IN. FROM EACH SURFACE OF WALL. <br />C. FILL,VOID OR CAVITY MATERIALS* — CAULK OR SEALANT — WHEN MINERAL WOOL BATT <br />INSULATION IS USED, APPLIED TO FILL THE STEEL SLEEVE TO A MIN DEPTH OF 1/2 IN. ON BOTH <br />SIDES OF WALL ASSEMBLY. WHEN BACKER ROD IS USED, A MIN THICKNESS OF 1 IN. OF CP-25WB+ <br />CAULK IS REQUIRED FLUSH WITH SURFACE OF WALL. A NOM 1/4 IN. DIAM CONTINUOUS BEAD OF <br />CAULK OR SEALANT SHALL BE APPLIED AROUND THE CIRCUMFERENCE OF THE STEEL SLEEVE AT ITS <br />EGRESS FROM THE GYPSUM WALLBOARD LAYERS ON BOTH SIDES OF THE WALL ASSEMBLY. <br />K]b<KU51l_l.IQ9i�by5`I a�l_l�l�:t�l:a� II�1�I�I�1•'PI�9�_1�1.IM <br />*BEARING THE UL CLASSIFICATION MARKING <br />PIPE TH ICU DATED WALL DETAIL <br />SCALE: N.T.S. <br />COLD WATER <br />BRANCH LINE <br />TO CW WATER <br />IN DETAIL MAIN IN rFII INCA <br />/ ADAPTERS AND SOFT <br />COPPER TUBES SIZE OF <br />CUBER CONNECTION TO (2) <br />CUBER WATER INLETS. <br />CONNECT TO CUBERS <br />ICE BIN o AND ICE BIN DRAIN <br />OUTLETS AS REQ'D. <br />3/4" REFER TO "INDIRECT/ <br />CONDENSATE DRAIN" <br />FLOOR CO1 DETAIL FOR MORE <br />INFORMATION. <br />NOTES: FLOOR SINK <br />PROVIDE FLOOR SINK AT SIDE EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR CLEANING - NOT UNDER <br />ANY EQUIPMENT. PROVIDE COLD WATER ROUGH -IN AT TOP OF ICE MACHINES. ARRANGEMENT SHOWN IS <br />SCHEMATIC. ADJUST AS REQUIRED TO SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. <br />ICE MACHINE PIPING DETAILS <br />SCALE: N.T.S. <br />TRAP -PRIMER PIPING DETAIL <br />SCALE: N.T.S. <br />EJ�Jg JJ !D <br />P J117rjJJJ <br />SJe�rw cJe�s� Irn1 rm <br />ADR: 3119 Central Parkway, <br />Dublin CA. 94568 <br />TEL: 510-788-6029 <br />CEL: 510-468-0613 <br />FAX: 510-788-6039 <br />Revisions Date <br />PROGRESS REVIEW 10-01-2018 <br />PERMIT SET 10-29-2018 <br />Preliminary Set <br />Design Review Set <br />Plan Check Set X <br />Plan Check Resubmit <br />Construction Set <br />1 <br />W <br />z <br />� W <br />Qw <br />0 <br />m � <br />V � <br />oz <br />LOa <br />z <br />00 � <br />O. <br />O <br />J � <br />O d' <br />2 Q <br />Z U <br />2 <br />Q ZO <br />LLI <br />0o U <br />LO <br />00 Cn <br />Scale: AS NOTED <br />Drawn By: AL <br />Approved By: JP <br />Job: 18033 <br />Sheet <br />PLUMBING <br />DETAILS <br />of: <br />PB -0.3 <br />