GENERAL NOTES: KITCHEN GENERAL NOTES: PLUMBING FIXTURE SCHEDULE:
<br /> 1. PLUMBING SYMBOLS
<br /> DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE
<br /> 1. REFERENCE THE KITCHEN EQUIPMENT PLUMBING CONNECTION FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT c~ 0
<br /> GENERAL SCOPE OF THE WORK. PRIOR TO SUBMITTING BID, VISIT 14. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO SCHEDULE FOR ITEMS TO BE FURNISHED AND / OR INSTALLED AS ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP © o
<br /> THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE TURNING BUILDING OVER TO THE OWNER. REQUIRED TO COMPLETE THE INSTALLATION OF PLUMBING DRAWINGS ON EACH OF THESE ITEMS. REFER TO ANNOTATION ' � � � �
<br /> PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND 15. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL SYSTEMS FOR KITCHEN EQUIPMENT. REFERENCE KITCHEN SPECIFICATIONS FOR FURTHER INFORMATION AND INSTALLATION " C
<br /> PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE AUTHORITIES. EQUIPMENT DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT REQUIREMENTS. VERIFY ROUGH-IN REQUIREMENTS WITH PLUMBING PLAN NOTE CALLOUT LO
<br /> co "T o
<br /> SPECIFICALLY CALLED OUT IN THIS PORTION OF THE O
<br /> COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DRAWINGS AND COORDINATE WITH THE OWNER FOR EXACT MANUFACTURER'S RECOMMENDATIONS. REFER TO THE PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED as
<br /> CONSTRUCTION DOCUMENTS. NOTIFY OWNER'S CONSTRUCTION AND ROUGH-IN. REFERENCE THE KITCHEN EQUIPMENT SHOP MANUFACTURER'S INSTALLATION INSTRUCTIONS AND INSTALL PER c'
<br /> MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO 16. DO NOT INSTALL PIP ` J AND INSTALLED). REFER TO PLUMBING FIXTURE ORE EQUIPMENT Q U!P
<br /> MOUNTING HEIGHTS. SCHEDULES c
<br /> ARCHITECTURAL DRAWINGS FOR THE PLUMBING FIXTURE PIPING OVER ELECTRICAL PANELS. REQUIREMENTS PRIOR TO THE START OF INSTALLATION. Q Q
<br /> SUBMISSION OF BID. ti v
<br /> 17. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST 2. PROVIDE ITEMS AND WORK AS REQUIRED FOR A COMPLETE AND p
<br /> 2. PROVIDE A CONSTRUCTION RECORD SET OF "AS-BUILT" INHIBITOR PAINT. PAINT AND COLOR SHALL BE COORDINATED WORKING PLUMBING INSTALLATION FOR EACH PIECE OF KITCHEN EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR W CLu : LO
<br /> DOCUMENTS TO THE OWNER'S CONSTRUCTION MANAGER WITH THE ARCHITECT AND / OR OWNER. O LO
<br /> EQUIPMENT. PROVIDE ROUGH-INS AND GflNNECT TO THE KITCHEN AP P • JAY R. SMITH # 4762 - 12" x 12" - CL, INSTALLED, SEE KITCHEN EQUIPMENT SCHEDULE FOR
<br /> 14 CL
<br /> REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS TYPE 304 STAINLESS STEEL PANEL AND FRAME WITH CONCEALED 18 JANITOR'S $I,UK ZURN # Z-1996-24, 24" x 24" x 10" HIGH SPECIFICATIONS) (D cel W
<br /> OR EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS, EQUIPMENT WITH TRAPS, SUPPLIES, SHUTOFF VALVES, PIPES TO HINGE, KEY OPERATED CYLINDER LOCK. PROVIDE WITH NAILER TERRAZZO BASIN WITH INTEGRAL STAINLESS STEEL DRAIN BODY. RTU MECHANICAL EQUIPMENT DESIGNATIO U o
<br /> 18. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. THE WALL, ESCUTCHEONS, ETC AS SHOWN, SPECIFIED AND N (CONTRACTOR FURNISHED L j CO CD
<br /> REFER TO SPECIFICATIONS. MAINTAIN 10' MINIMUM CLEARANCE FROM ALL AIR INTAKES. REQUIRED. SLOTS FOR INSTALLATION IN STUD WALLS AND ANCHOR STRAPS FAUCET: ZURN MODEL # Z1996-SF, S" CENTERSET, FAUCET WITH I AND INSTALLED UNLESS NOTED OTHERWISE) d
<br /> 3, PROVIDE TO THE OWNER'S CONSTRUCTION MANAGER A DOPY OF -
<br /> MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT, FOR INSTALLATION IN MASONRY CONSTRUCTION. WALL BRACE, INTEGRAL VACUUM BREAKER, PAIL HOOK AND 3/4"
<br /> 3. VERIFY GAS LOADS AND GAS ROUGH-IN OF KITCHEN EQUIPMENT MALE HOSE THREADED OUTLET, SECURE FAUCET IN WALL WITH CONNECTION POINT OF NEW WORK TO EXISTING
<br /> INSPECTION REPORTS AND APPROVAL. CERTIFICATES FROM 19. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH WITH THE KITCHEN EQUIPMENT SHOP DRAWINGS PRIOR TO 8FP DOUBLE GFi£CK ASSE,M LY BACKFLOW PREVENT; BACKBOARD.
<br /> LOCAL AND STATE INSPECTIONS, REFER TO SPECIFICATIONS. VERIFY EXISTING CONDITIONS. THE SUBMISSION OF A BID WILL BE INSTALLING GAS PIPING. PROVIDE GAS COCKS, UNIONS, ETC. AS WATTS # 719QT-5, CAST BRONZE BODY, QUARTER TURN TEST TRIM: T-35 THREE FOOT LONG REINFORCED HOSE WITH 1 DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER
<br /> 4, INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED
<br /> MINIMUM 2" BATT INSULATION TO PREVENT FREEZING. SPECIFIED AND REQUIRED. INSTALL GAS QUICK DISCONNECTS COCKS, QUARTER TURN BALL VALVES, BRONZE STRAINER, AND # 3/4" CHROME COUPLING AND WALL HOOK, # V-70 EXTRUDED VINYL P1 LOWER NUMBER INDICATES SWEET NUMBER
<br /> 909AG AIR GAP FITTING. BUMPER GUARD.
<br /> CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING 20. EXAMINE THE CONTRACT DRAWINGS AND ALL AVAILABLE WHERE FURNISHED WITH THE KITCHEN EQUIPMENT. TMV THERMOSTATIC MIXIIV�„•VALVE- POWERS # e480, SOLID ABBREVIATIONS 0
<br /> JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE INFORMATION CONCERNING EXISTING INSTALLATION, STRUCTURE, 4. PROVIDE INDIRECT WASTE LINES OF SAME SIZE AS CONNECTION A S T AMTRbL "THERM-X-TROL" # ST-5, BRASS BODY THERMOSTATIC WAX NELEMENT, CORROSION AFF ABOVE FINISHED FLOOR MH MANHOLE
<br /> LANDLORD. OBTAIN A COPY OF THE LANDLORD'S AND LOCAL CONDITIONS. VISIT THE SITE TO UNDERSTAND THE TO EQUIPMENT WITH 3/4" BEING MINIMUM SIZE, ROUTE FROM WELDED STEEL PRESSURE TANK, POLYPROPYLENE LINING, RESISTANT INTERNAL PARTS, AND INTEGRAL CHECKS, A55E 1070
<br /> REQUIREMENTS AND REVIEW PRIOR TO SUBMITTING BID. NATURE AND SCOPE OF ALL WORK TO BE PERFORMED AND EQUIPMENT CONNECTION POINTS INDICATED TO FLOOR DRAIN OR FLEXIBLE BUTYL DIAPHRAGM, AIR CHARGING VALVE, 150 PSI AFG ABOVE FINISHED GRADE MIN MINIMUM V
<br /> FLOOR SINK. PROVIDE AIR GAP OF TWO PIPE DIAMETERS MAXIMUM WORKING PRESSURE, 2.0 GALLON CAPACITY, 0.45 COMPLIANT, CAPABLE OF 2.2 GPM WITH . 20 Psi DIFFERENTIAL AHU AIR HANDLING UNIT N/C NORMALLY CLOSED
<br /> AND A MINIMUM FLOW RATE OF 0.5 GPM. SET TEMPERATURE TO z
<br /> 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED TAKEN AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MINIMUM PER CODE. MAXIMUM ACCEPTANCE FACTOR, 3/4" PIPE CONNECTION. SET THE BFF BELOW FINISHED FLOOR
<br /> CODE REQUIREMENTS. MADE AND THAT ALL EXISTING CONDITIONS HAVE BEEN 11OF FOR DUEL TEMPERATURE LAVATORIES AND HAND SINKS, N/O NORMALLY OPEN
<br /> AIR CHARGE PRESSURE TO MATCH EXISTING WATER SYSTEM
<br /> CONSIDERED. NO ALLOWANCES WILL BE MADE AFTER THE 5. COMPLY WITH HEALTH DEPARTMENT REGULATIONS, PROVIDE PRESSURE, 100F FOR SINGLE TEMPERATURE LAVATORIES AND HAND SINKS BFG BELOW FINISHED GRADE ORD OVERFLOW ROOF DRAIN
<br /> 6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CLEARANCE FOR CLEANING BEHIND AND UNDER EXPOSED PIPING AND 120E FOR SINKS. MOUNT BELOW THE PLUMBING FIXTURE BOP BOTTOM OF PIPE
<br /> PDI PLUMBING DRAINAGE INSTITUTE
<br /> CONNECTION BEFORE START OF PIPING INSTALLATION. CONDITIONS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY AS REQUIRED BY HEALTH DEPARTMENT. CONFORM TO HEALTH FCO F U : SIOUX CHIEF # 852 SERIES WITH WHERE INDICATED ON PLAN(S). Bas BOTTOM OF STRUCTURE PVC POLYVINYL CHLORIDE W
<br /> DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THAT DEPARTMENT REQUIREMENTS FOR LOCATIONS OF FLOOR SINKS. SQUARE SCORIATED MEDIUM DUTY CAST NICKEL ADJUSTABLE BTU BRITISH THERMAL UNIT pRy PRESSURE REDUCING VALVE
<br /> 7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND OF THESE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. TP TRAP"PRIME
<br /> PRECISION PLUMBING PRODUCTS # PR- CPUC CHLORINATED POLYVINYL
<br /> MOUNTING HEIGHTS OF PLUMBING FIXTURES. TOP, IN UNFINISHED AREAS, WITH FLANGED PVC ADAPTER WITH 500 PRIME RITE , CORROSION RESISTANT BRASS BODY, O RING CHLORIDE RD ROOF DRAIN
<br /> 6. PROVIDE AIRTIGHT SEAL AROUND PIPING PENETRATIONS BLANK TRAP PRIMER PORT AND POLYPROPYLENE THREADED SEALS, 1/2 INLET AND OUTLET AND INTEGRAL VACUUM BREAKER. RPM REVOLUTIONS PER MINUTE
<br /> 8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION 21. PLUMBING CONTRACTOR MUST PROVIDE CAMERA VERIFICATION THROUGH WALK-IN COOLER OR FREEZER WALLS OR CEILINGS. PLASTIC PLUG WITH THREADED BRASS INSERT. INSTALL WITW INSTALL THE VALVE AT A MINIMUM OF 12" ABOVE FINISHED FLOOR. DN Dowty RTU ROOFTOP UNIT
<br /> OF PIPE ROUTING. VE EXACT LOCATION OF WASTE LINE TO SS DURING BID. CARPET MARKER IN CARPETED FLOOR AREAS. CLEAN AND PROVIDE WITH DISTRIBUTION # DU-2 FOR TWO, # DU-3 FOR THREE, DFU DRAINAGE FIXTURE UNIT SF SQUARE FEET 5 THIsnRAwINGI
<br /> VERIFICATION MUST BE MADE PRIOR TO ISSUANCE OF PERMIT SUPPLY FAN SANINSTRUMENTOF
<br /> 9. INSTALL CONGEALED PIPING TIGHT TO THE STRUCTURE AND A5 7. DO NOT INSTALL PIPING IN COOLER OR FREEZER WALLS. INSTALL POLISH TOP AFTER INSTALLATION WHERE EXPOSED. REFER TO OR # DU-4 FOR FOUR DRAIN CONNECTIONS. Ds DOWNSPOUT ' SERUICEaNpA5SUCHSHALLREMAIN
<br /> AND AFTER ACCEPTANCE OF CONTRACT TO PROCEED. EXPOSED PIPING IN A NEAT APPEARING MANNER. SPECIFICATIONS FOR INSTALLATION. SP SUMP PUMP THE PROPERTY OF NEPTUNE DESIGN
<br /> HIGH AS POSSIBLE. INSTALL EXPOSED PIPING TIGHT TO THE ETR EXISTING TO REMAIN SS STAINLESS STEEL, SANITARY GROUPLLC.UNAUTHOREZEgUSE OF
<br /> STRUCTURE, WALL OR CEILING AND AS HIGH AS POSSIBLE. EWC ELECTRIC WATER COOLER SEWER, SOIL STACK RETHEARCHITE ARCH
<br /> ITECT
<br /> HIBITE .THI
<br /> COORDINATE WITH OTHER TRADES TO AVOID CONFLICTS. 22. CONTRACTOR TO FIELD VERIFY EXISTING DOMESTIC WATER 8. COORDINATE FLOOR DRAIN LOCATION AND FLOOR SLOPE FD FLOOR RAIN: ZURN # FD-2320--NH3-ST-P, CAST IRON WGO CLEANOUT: SIOUX CHIEF #873 SERIES, BRASS OFPRODUC REPRODUCTION
<br /> HOOT PERMISSION
<br /> SYSTEM IS PROVIDED WITH A REDUCED PRESSURE BACKFLOW REQUIREMENTS WITH THE ARCHITECT. BODY AND CLAMPING COLLAR, ADJUSTABLE 6" SQUARE NICKEL COUNTERSUNK PLUG, 20 GAUGE STAINLESS STEEL COVER AND FD FLOOR DRAIN TDM TOTAL DYNAMIC HEAD DRAWING IS ONLY FOR USE IN
<br /> 10. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. PREVENTER (RPBP). IF NOT EXISTING, PROVIDE AN APPROVED FFA FROM FLOOR ABOVE CONNECTIDNWITHTHtsPRG�ECTaNq
<br /> BRONZE STRAINER. USE PUSH-ON JOINT OF OUTLET SIZE AS SCREW. CLEANOUT TEE Td BE PROVIDED SEPARATELY. REFER TFA TO FLOOR ABOVE SHALL NOT BE USED FOR OTHER
<br /> RPBP ASSEMBLY SIZED TO MATCH BUILDING WATER METER. 9. INSTALL RIM OF FLOOR DRAINS AND FLOOR SINKS BELOW SHOWN ON PLANS. TO SPECIFICATIONS FOR INSTALLATION, FFB FROM FLOOR BELOW LOCaT10NS.COPYRIGFfT201b.
<br /> 11. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; INSTALL NEW RPBP BETWEEN THE WATER METER AND THE TFB r0 FLOOR BELOW
<br /> FINISHED FLOOR LEVEL. SLOPE FLOOR TO DRAINS. REFER TO FF FINISHED FLOOR TFB TYPICAL
<br /> EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED AS BUILDING PER LOCAL JURISDICTION'S REQUIREMENTS. ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. FS FLOOR SINK: ZURN # FD2375, 6" DEEP CAST IRON BODY WHA .WATER HAMMER ARRESTS PRECISION PLUMBING FL FLOW LINE
<br /> HIGH AS POSSIBLE AND TIGHT TO WALLS. WITH ACID RESISTING ENAMELED INTERIOR, ANCHOR FLANGE WITH PRODUCTS, HARD DRAWN COPPER BODY WITH WROUGHT FLA FULL LOAD AMPS UL UNDERWRITERS LABORATORIES,
<br /> 12. COORDINATE ALL WORK WITH OTHER TRADES AND 10. COORDINATE LOCATION OF VENT, WATER, AND GAS PIPING TO SEEPAGE HOLES, CLAMP COLLAR, ABS DOME STRAINER, NICKEL COPPER FITTINGS, PISTON TYPE WITH LUBRICATED EPDM "0" RING FLA FLOOR INC.
<br /> AVOID CONFLICT WITH OTHER TRADES. BRONZE RIM AND HALF/FULL GRATE, USE CAULK JOINT OF SEALS, MEETING ASSE 1010 OR PDI WH-201. PROVIDE PDI SIZES UNO UNLESS NOTED OTHERWISE
<br /> CONTRACTORS. „ GPM GALLONS PER MINUTE UPS UNINTERRUPTIBLE POWER SUPPLY
<br /> 13. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE OUTLET SIZE AS SHOWN ON PLANS. A' THROUGH F A5 SHOWN ON PLANS. PROVIDE SIZE "A" UNLESS Wp HEAD, NUB DRAIN
<br /> BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING 11. CLEAN INSTALLED PLUMBING FIXTURES AND EQUIPMENT. SHOWN OTHERWISE ON THE PLANS. V VOLT(S)
<br /> LV A - T VAT Y A 5 AMERICAN I£ INVERT ELEVATION VCP VITRIFIED CLAY PIPE
<br /> THROUGH GRADE BEAMS, FOOTING, ETC, WHERE REQUIRED AND 12. PROVIDE WALL BACKING OR SPECIFIED CARRIERS FOR THE STANDARD 0355.012 "LUCERNE" 20-1/2" X 18-1/4" RECTANGULAR WALL WC FLOOR-MOUNTED T IN WC INCHES OF WATER COLUMN
<br /> AS NOTED ON PLANS. COORDINATE SLEEVE INSTALLATIONS WITH # � „WA ER CLr,OS TT (ADA .,A CESSIBLE� VENT STACK �
<br /> THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL PROPER SUPPORT OF INSTALLED WALL HUNG FIXTURES AND MOUNTED WHITE VITREOUS CHINA FIXTURE WITH FAUCET LEDGE AND AMERICAN STANDARD 3043.001 "MADERA" WHITE VITREOUS CHINA JB JUNCTION BOX VTR VENT THROUGH ROOF �
<br /> CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS EQUIPMENT. FRONT OVERFLOW. # J-BOX JUNCTION BOX O
<br /> Q CV
<br /> INSTALLED. AU FIXTURE WITH ELONGATED UNIVERSAL BOWL AND DIRECT-FED SIPHON W/ WITH PROVIDE WITH SLOAN # ETF-600-LT 4" CENTERSET, JET ACTION. LOW CONSUMPTION TYPE AND MEETS DEFINITION FOR HIGH kW KILOWATT w/o WITHOUT
<br /> 13. PROVIDE VERTICAL LIFT SPRING LOADED CHECK VALVES IN HOT HARD WIRED, SENSOR OPERATED FAUCET LESS TRANSFORMER WITH EFFICIENCY TOILET (HEI). MAU MAKE--UP AIR UNIT Ln
<br /> Ln
<br /> AND GOLD WATER SUPPLIES FOR 3-COMPARTMENT SINKS, PRE- "Y" STRAINER FILTERED SOLENOID VALVE AND 0.5 GPM AERATOR. VALVE: SLOAN "SLOAN" # 111-1.28 1.28. GALLON PER FLUSH, MAX MAXIMUM WC WATER COLUMN
<br /> RINSE UNITS, JANITOR SINKS, MIXING DOSE BIBBS & MIXING WALL TRIM:: McGUIRE # 155A GRID DRAIN WITH TAILPIECE McGUIRE EXPOSED CHROME-PLATED DIAPHRAGM 'TYPE FLUSH VALVE WITH MBH 1000 BTU PER HOUR WS WASTE STACK O Q
<br /> FIXTURE BRANCH CONNECTION SCHEDULE HYDRANTS DOWNSTREAM OF SHUTOFF VALVES. # 2165CCLK LOOSE KEY COMPRESSION ANGLE STOP VALVES WITH CHLORAMINE RESISTANT DIAPHRAGM AND PROTECTED ORIFICE, wSFU WATER SUPPLY FIXTURE UNI V
<br /> T
<br /> RISERSAND ESCUTCHEONS, McGUIRE # 68872CF 1-1/4" 17 GAUGE CAST OSCILLATING ADA COMPLIANT HANDLE, ESCUTCHEON, INTEGRAL J z
<br /> FIXTURE COLD WATER HOT WATIER WASTE VENT CHROME PLATED BRASS ADJUSTABLE P-TRAP AND WASTE ARM WITH SCREWDRIVER STOP WITH VANDAL RESISTANT CAP, VACUUM BREAKER
<br /> CLEANOUT PLUG AND ESCUTCHEON, CONCEALED ARM CARRIER WITH PIPING 0
<br /> STANCHIONS TO FLOOR, PLUMBEREX "PRO-EXTREME" AND SWEAT ADAPTER KIT. INSTALL FLUSH VALVE HANDLE ON THE WIDE
<br /> WATER CLOSET{VALVE) 1-114" -- 4" 2,� # X-4222 SIDE OF THE STALL.
<br /> LAVATORY 112" 112" 2° 2" Y
<br /> INSULATION KIT FOR WATER AND WASTE PIPES. TRIM: CHURCH # 950OSSC WHITE OPEN-FRONT CONTOURED, DOMESTIC COLD WATER (CW) z
<br /> SOLID PLASTIC, HEAVY DUTY, SEAT LESS COVER WITH SELF-SUSTAINING -- DOMESTIC HOT WATER (HW) 00 V
<br /> JANITOR'S SINK 314" 314" 3„ 2„ LOW PRESSURE GAS DCV V T 5 H RT• WATTS # SD-3, CHECK HINGES AND STAINLESS STEEL DOLTS. Q
<br /> PIPE SIZING CHART 316 STAINLESS STEEL BODY, ASSE 1022 COMPLIANT, 3/8" INLET AND T TRAP PRIMER LINE (T)
<br /> 3,. 2.. PIPE
<br /> FLOOR SINK -_ _ OUTLET, ATMOSPHERIC PORT, AND WYE PATTERN STRAINER, S SOIL PIPING - ABOVE FLOOR (S)
<br /> _
<br /> FLOOR DRAIN 2" SIZE LOAD {CFH)
<br /> --S-- SOIL PIPING - BELOW FLOOR (5)
<br /> -_ _- 2"
<br /> TES: 1/2" 50 W WASTE PIPING - ABOVE FLOOR (W)
<br /> IPE SIZES SHOWN ARE MINIMUM. 314" 105 --W -- WASTE PIPING - BELOW FLOOR (W)WATER AN GW GREASE WASTE - ABOVE FLOOR (GW)
<br /> 1,. 197 D WASTE FIXTURE COUNT - --GW-- - GREASE WASTE - BELOW FLOOR (GW)
<br /> TOTAL CONNECTED NATURAL GAS LOAD 1-114" 404 D.F U. TOTAL HOT COLD COMBINEE TOTAL TOTAL TOTAL - -- -VBG- - - VENT BELOW GRADE (VBG)
<br /> FIXTURE TYPE new QTY (EA) D.F.U. S.F.U. S.F.U. S.F.U. S.F.U. S.F.U. SERVICE -VBF-- -•- VENT BELOW FLOOR (VBF)
<br /> KITCHEN EQUIPMENT - 6D6 (EA) (EA) (EA) (HOT) (COLD) S.F.U. - CD CONDENSATE DRAIN (CD) d
<br /> 2" 1,167 LAVATORY 2 1.0 2.0 0.75 0.75 1.00 1.5 1.5 2.0 NATURAL GAS (G)
<br /> EQUIPMENT 2-112" 1,859 SERVICE SINK(MOP BASIN) 1 3.0 3.0 2.25 2.25 3.00 2.25 2.25 3.0
<br /> G
<br /> DESIGNATION DESCRIPTION CFH (EACH) FLOOR DRAIN 6 2.o 12.0 0.00 0.00 0.00 o 0 0.0 EXISTING PIPING TO REMAIN
<br /> 24 FRYER 100
<br /> OPERATING PRESSURE OF 7"WC WITH A WATER CLOSET(1.28 GPF FLUSH VALVE) 2 4.0 8.0 0.00 2.50 2.50 0 5 5.0 ---V- - - - VENT PIPING (V)
<br /> PRESSURE DROP OF 0.5"WC _- c o
<br /> SPECIALTY KITCHEN EQUIP. ® SQUARE FLOOR DRAIN (FS), SIZE & TYPE
<br /> 24 FRYER 100 TOTAL DEVELOPED LENGTH = 100 FEET SINK(HAND)(2"DW) 2 2.0 4.0 1.50 1.50 2.00 3 3 4.0 � ROUND FLOOR DRAIN (FD), SIZE & TYPE
<br /> 23 RANGE 227 TOTAL CONNECTED LOAD = 1066 CFH SINK(2-COMPARTMENT)(2" W) 1 3,0 3.0 1.50 1.50 2.00 1.5 1.5 2.0 -- _ +A -- - BALL VALVE
<br /> 25 GRIDDLE 219 BASED ON 2016 CPC TABLE 1216.2 1
<br /> SINK(3 COMPARTMENT)(2" IW) 1 4.0 4.0 3.00 3.00 4.00 3 3 4.0 CONTROL VALVE
<br /> SODA MACHINE(314" IW) 2 0.5 1.0 0.00 1.00 1.00 0 2 2.0
<br /> 22 RICE COOKER35 TEA MAKER(314"IW) 2 0.5 1.0 0.00 0.50 0.50 0 1 1.0 SHUTOFF VALVE
<br /> GREASE INTERCEPTOR SIZING CHECK VALVE
<br /> ICE MACHINE 314"!W 2 D.5 1.o Q.00 0.50 0.50 0 1 1.0
<br /> 22 RICE COOKER 35 HOT FOOD TABLE (314" IW) 1 0.5 0.5 0.75 0.75 1.00 0.75 0.75 1.0
<br /> 45 GRIDDLE 100 C'
<br /> FIXTURE TYPE O as
<br /> W GW DIPPER WELL(314" IW) 2 0.5 1.0 0.00 0.75 0.75 0 1.5 7.5 �
<br /> QTY D.F.U D.F.U. UNION
<br /> CAP
<br /> 1 3.0 3.0
<br /> TOTAL = 816 SERVICE SINK(MOP BASIN) (EA) TOTAL TOTAL UNITS: 24 40.5 12.00 22,50 26.50 �I WALL CLEANOUT (WGO)
<br /> MECHANICAL EQUIPMENT SINK(HAND)(2"DW) 2 2.0 4.0 U FLOOR CLEANOUT (FCO)
<br /> SINK(2 COMPARTMENT)(2" IW) 1 3.0 3.0 Q EXTERIOR CLEANOUT (ECO)
<br /> EQUIPMENT SINK(3 COMPARTMENT)(2" IW) 1 4.0 4.0 WATER PIPE SIZING CHART
<br /> DESIGNATION DESCRIPTION CFH (EACH) 2"FLOOR DRAIN IN GREASE PRODUCING AREA 2 2.0 4.0 FIXTURE UNITS VS. PRESSURE LOSS
<br /> ---- io ELBOW UP
<br /> ESTIMATED TOTAL GREASE WASTE DRAINAGE FIXTURE UNITS: 18.0 IN PSI 1 100 FEET FOR TYPE "L" COPPER TUBE
<br /> ----+o ELBOW DOWN
<br /> WH-1 WATER HEATER 50 PER TABLE 1014.3.6 OF THE 2016 CPC, 18 DFU CAN BE COLD WATER 51 PSI 1100' HOT WATER . 5.0 PSI 1 00' TEE UP
<br /> RTU-1(EXISTING) R001= TOP UNIT PLUMBED TO AN EXISTING 1,200 GALLON GREASE INTERCEPTOR PIPE FLUSH TANK FLUSH VALVE VELOCITY FLOW FLUSH TANK VELOCITY FLOW •- TEE DOWN
<br /> 60 --
<br /> RTU
<br /> SIZE SFU SFU FEET/ SEC GPM SFU FEET/ SEC GPM � ELBOW UP WITH SHUT-OFF VALVE (SOV)
<br /> -2(EXISTING) ROOF TOP UNIT 60 Number o#,DFU's '18.Q ---�-+-� ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
<br /> RTU-3 ROOF TOP UNIT 80 TABLE 10-3 3/411 6.9 WA 3.9 6.3 TEE UP WITH SHUT-OFF VALVE (SOV)
<br /> TOTAL = 250 GRAVITY GREASE INTERCEPTOR SIZING 1" 16 NIA 4.7 12.5 IN TEE DOWN WITH SHUT-OFF VALVE (SOV)
<br /> 1-114" 32 4 5.4 22.0 „
<br /> 19.75 5 19.5 I A WATER HAMMER ARRESTER (WHA)
<br /> DFU's(1) INTERCEPTOR VOLUME(2) 1-112" 59.6 15.8 5.9 35.0 44.3 5 27.5 WITH PD1 SIZES, (A, B, C, D, & E)
<br /> TOTAL CONNECTED LOAD = 1066 2" 214 116 7.5 72.0 120 5 48 ITS GAS COCK REVISION
<br /> $ 500 gallons 2-112" 476 360 8 119.3 245 5 74
<br /> 21 (3) 750 gallons 3„ 748 700 8 170 407.9 5 106.5 TRAP PRIMER
<br /> 35 1,000 gallons TRAP PRIMER WITH DISTRIBUTION UNIT lz�
<br /> NATURAL GAS SYSTEM OPERATING PRESSURE OF 7 INCHES WC 90(3) 1,250 gallons 4" 1746 700 8 299 07. 5 186.0
<br /> NATURAL GAS SYSTEM SIZED WITH TOTAL DEVELOPED LENGTH FROM GAS METER TO 172 1,500 gallons 1 6" 1 10300 1 10300 8 1 1170.0 4849 5 641.0216 2,000 Uallons . SIZED WITH HAZEN WILLIAMS CONSTANT"C = 135" * UTILIZE COLD WATER SIZING CHART Q
<br /> MOST REMOTE PIECE OF EQUIPMENT OF 1 00'WITH A PRESSURE DROP OF 0.5 INCHES W.C.
<br /> PLUMBING PIPE MATERIAL SCHEDULE
<br /> KITCHEN FIXTURE CONNECTION SCHEDULE IA3
<br /> HOT COLD WASTE DATE: 03.09.2018
<br /> PIPING SYSTEM ABBREVIATION PIPING MATERIAL
<br /> TAG# FIXTURE/EQUIPMENT WATER WATER VENT NOTES
<br /> (IN.) (IN.) INDIRECT DIRECT �4
<br /> SANITARY DRAINAGE & VENT(ABOVE GRADE:) S, W OR V HUBLESS CAST IRON 4 ICE TEA DISPENSER 112" 314" BEP, FILTERED WATER, TO FS
<br /> SANITARY DRAINAGE & VENT(BELOW GRADE) S, W OR V PVC DWV 6 BEVERAGE DISPENSER 1/2" 314" BEP FILTERED WATER, TO FS
<br /> POTABLE WATER (ABOVE GRADE) CW, HW OR HWR TYPE L HARD DRAWN COPPER WITH SOLDERED JOINTS 12 WALL MOUNTED HANDSINK 112" 1/2" 2" 21
<br /> 1 REVIEW SET
<br /> TABLE WATER -2" & SMALLER(BELOW GRADE) CW, HW OR HWR TYPE K SOFT ANNEALED COPPER 15 3-COMPARTMENT FAUCET SINK 314" 314" (3) 2" 12" SWING SPOUT NOT FORPERMIT
<br /> NATURAL GAS (ABOVE GRADE & ON ROOF) G SCHEDULE 40 BLACK STEEL 16 2-COMPARTMENT FAUCET SINK 112" 1/2" 2" 12" SWING SPOUT, TO FS WATER HEATER SCHEDULE
<br /> NATURAL GASBELOW GRADE)) G APPROVED 'PE' PIPE FOR GAS 18 MOP SINK AND FAUCET 314" 3/4" 3" 2" INTEGRAL VACUUM BREAKER MANUFACTURER/& SMALLER
<br /> CONDENSATE DRAIN AREA TANK SIZE r RECOVERY ENERGY
<br /> - 1" CD TYPE M HARD DRAWN COPPER 28 3-WELL WARMERS 1/2" 3/4" BFP, TO FS MARK MODEL## SERVED ENERGY SOURCE (GALLONS) I 80 DEGREE RISE FACTOR NOTES
<br /> CONDENSATE DRAIN - 1-1/4" & LARGER CD TYPE DWV HARD DRAWN COPPER ## CARBONATOR 1I2" DCV, FILTERED WATER WH-1 BRADFORD WHITE ULG2PDV54H503N KITCHEN/ LAVS NATURAL GAS 48 50 MBH 60 0.68 A B PLUMBING
<br /> INDIRECT DRAIN - 1"& SMALLER ID TYPE M HARD DRAWN COPPER 29 DIPPER WELS112" 314" SCHEDULES &
<br /> TO F5 NOTES:
<br /> INDIRECT DRAIN - 1-114" & LARGER ID TYPE DWV HARD DRAWN COPPER 37 BAG-N-BOX SODA SYSTEM 4" PVC CONDUIT A. 80F TEMPERATURE RISE WITH 140F OPERATING TEMPERATURE. NOTES
<br /> REFER TO SPECIFICATIONS FOR FITTINGS, INSTALLATION REQUIREMENTS AND FURTHER INFORMATION 52 BEVERAGE DISPENSER 314" DRAIN TO FS B. FURNISH WITH FACTORY COMBUSTION AIR INTAKE AND EXHAUST KIT
<br /> Fn
<br /> 53 ICE MACHINE 112" 3/4" BFP, FILTERED WATER, TO FS
<br />
|