t <br /> i 5355 Solari Ranch Rd. <br /> Stockton,Ca.,95215 <br /> 209-931-1375 <br /> Fax:209-931-2373 <br /> Smith& Associates <br /> Civil Engineers <br /> 5355 Solari Ranch Rd. <br /> Stockton, Ca.,95215 j <br /> December 14, 1998 <br /> FOR: Federico,Vittorio& M J <br /> 1101 W. Harney Ln. <br /> Lodi,Ca. 95242 <br /> RE: Soil Suitability Study <br /> PROJECT: MS 98-37 APN 058-020-16 <br /> SUBJECT: Percolation Testing <br /> On December 8, 1998 percolation test was completed at 1101 W. Harney Lane. The location of the test area <br /> was identified by a representative from Seibel&Associates,Lodi,California. <br /> A Registered Sanitarian from the San Joaquin County's Department of Environmental Health was present <br /> for the last two readings. The testing was performed in accordance with the Department's percolation test <br /> procedures. <br /> Two holes were drilled using a hand auger. One hole was tested and the other hole was for verification of <br /> the soil profile. The hole diameters measured 7" at the top. Sleeving of the holes was not required. Gravel <br /> was placed in the bottom of the test hole. Test hole depth was 42". <br /> Please see attached report Form EH 05 119/84(90)of Field Percolation Testing. The soil,as tested, <br /> indicates it is conducive to percolation of clear sewage effluent. <br /> Submitted for inclusion in Soil Suitability Study. <br /> Earnest F. Smi , P <br />