Laserfiche WebLink
vs n <br /> Project F114.01 5 March 1992 <br /> • <br /> SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site: Exxon Station RS #7-1050 System Start Up: 3/8/91 <br /> 909 West Hammer Lane <br /> Stockton, California <br /> System Incinerator Incinerator Incinerator <br /> Test Date 2/28/92 2/13/92 1/7/92 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> VP-1 120 0 2 0 ND 0 <br /> VP-2 ND 0 4 0 NO 0 <br /> VP-3 NO 0 NO C NO 0 <br /> VP-4 25 0 ND C NO 0 <br /> VP-5 NO 0 15 0 5 0 <br />• <br /> VP-6 100 0 NO C ND C <br /> MW-3 280 0 38 0 30 0 <br /> MW-4 ND 0 ND 0 NO 0 <br /> Detection --- --- ---- <br /> Limit (ppm) 1.0 1.0 1.0 <br /> Method FID FID TLV <br /> EXTRACTION POINT - Extraction probe/well identification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (O-Open) (C-Closed) <br /> NT - Not tested. <br /> NO - Below the detection limit. <br /> - 2 - <br />