My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080932 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PALMQUIST
>
8891
>
2600 - Land Use Program
>
SR0080932 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2019 2:12:35 PM
Creation date
11/18/2019 1:47:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0080932
PE
2602
STREET_NUMBER
8891
Direction
W
STREET_NAME
PALMQUIST
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
24807024
ENTERED_DATE
7/23/2019 12:00:00 AM
SITE_LOCATION
8891 W PALMQUIST AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. Details and results of the percolation test are summarized <br /> in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 7/2/2019 3.13 5.43 4 hr. Satisfactor�r perc. <br /> Shallow Test rate <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. <br /> Because of the percolation rate between 5.0 and 30.0 min/in encountered in the test, <br /> hole, the San Joaquin County Environmental Health Department will require an eight- <br /> foot separation from the bottom of the dispersal system to ground water (see Table 2). <br /> Ground water is anticipated to be encountered approximately 110 to 132 feet below <br /> ground surface at the Site; consequently, no modifications to standard septic systems <br /> should be required. <br /> Discussion of Septic System Sizing <br /> Septic system construction should follow the San Joaquin County On-Site Wastewater <br /> Treatment Systems Standards (2017). <br /> LOGE 1922 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.