MONIT(VING SYSTEM CERTIFOATION <br /> CERTIFICATION / TEST DATE: October 25, 2011 <br /> Al. FACILITY A2. OWNER <br /> Name BP#29 Cruisers Manteca Name Boyett Petroleum <br /> Address 1137 W. Lathrop Road, Manteca,CA 95336 Address 601 McHenry Avenue, Modesto, CA 95350 <br /> Phone# 209-824-2760 Phone# 209-577-6000 <br /> Contact Rohda Henry Contact Rohda Henry <br /> I. RESULTS OF VACUUM/PRESSURE MONITORING EQUIPMENT TESTING <br /> Make / Model of Monitoring System: Veeder-Root TLS-350 <br /> System Type: ❑ Pressure ■ Vacuum. <br /> SensorlD <br /> Component(s)Monitored by this Sensor: 87 Product <br /> S1 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 87 Vent <br /> S2 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 87 Annular <br /> S3 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: Ey%-r <br /> S4 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 91 Product <br /> S6 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: 91 Venl <br /> S6 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: Diesel Product <br /> S7 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: Diesel Vent <br /> S9 Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: Diesel-91 Annular <br /> slo Sensor Functionality Test Result: ■ Pass; ❑ Fail Interstitial Communication Test Results: ■ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Results: ❑ Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> ❑ Leak Introduced at Far End of Interstitial Space:, ❑ Gauge: ❑ Visual Inspection: ■ Other(Describe in Sec.J,below) <br /> Vacuum was restored to operating levels in all interstitial spaces: ■ Yes ❑ No(If no,describe in Sec J,below) <br /> J. COMMENTS <br /> Leak was introduced at the test port. <br /> ,If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the sensor.vacuumipressure has been demonstrated to be communicating throughout the interstice. <br /> ©2011 Walton Engineering,Inc. <br /> Page 3a of 3 <br />