Laserfiche WebLink
Monitoring System Certification- Page 2 of 3 <br /> Site Address: 1137W. Lathrop Rd. Date of Testing/Servicing: 8/29/18 <br /> D. Results of Testing/Servicing <br /> Software Version Installed. 333.03 <br /> Complete the foll Ing checklist: <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ® Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g. modem) <br /> ❑ N/A operational? <br /> ® Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) H Sump/Trench Sensors; ® Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ® Yes ❑ No <br /> ® Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e,no <br /> ❑ N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 90 <br /> ❑ Yes* ® No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product;❑ Water. if yes,describe causes in Section E,below. <br /> N Yes ❑ No* I Was monito ing system set-up reviewed to ensure proper settings? Attach set-up reports, i a licable. <br /> Do Yes ❑ No* I Is all monitoring equipment operational per m.anufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Estops -Tested & Passed. <br /> 91 & Diesel are Split Tanks and Share Annular. <br /> All Sumps & UDC's are monitored by additional Brine Sensors (794380-304) -Tested & Passed. <br /> Vent Sump Sensor(794380-208) & (794380-304) -Tested & Passed. <br /> 87 STP Brine Port Needs Repaired and Brine Added. Left in L1 Low Liquid Alarm Until Repairs <br /> are made by Alternative Contractor. <br />