My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
INSTALL_2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:35:19 PM
Creation date
11/19/2019 2:57:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2009
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Integrated solution for centralized , <br /> single system site monitoring. <br /> Standard Models <br /> Console Form Number: 848290-022 <br /> Description: TLS-350 Plus monitoring console with integral printer <br /> Console Form Number: 848290-002 <br /> Description: TLS-350 Plus monitoring console without integral printer <br /> Console Form Number: 848291-021 <br /> Description: TLS-350 Plus PC version without printer,keyboard or display <br /> TLS-350 Plus Interface Modules <br /> The TLS-350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules <br /> mal he in the console upon initial ordering,or ordered scparatcly as spare module,to expand an existing stem. <br /> Form No. <br /> Factory <br /> Installed <br /> Modules Description Feature Compatibility(where applicable) <br /> LOW-POWER COMPARTMENT(Limit eight per conso)e,unless othe,w se noted) <br /> 329356-002 Four-Input Probe Interface Module(Maximum three per Series 8473 0.1 GPH Magnetostrictive Probe <br /> console.Includes terminal connector for one ground Series 8463 0.1 GPH Mag Plus Magnetostrictive Probe <br /> temperature thermistor for the volumetric line leak detector). <br /> 329358-001 Eight-Input Interstitial/Liquid Sensor Series 7943 Interstitial Sensor for Fiberglass Tanks and <br /> Interstitial Sensor for Steel Tanks <br /> Series 7943 Piping Sump Sensor <br /> Series 7943 Hydrostatic Sensor <br /> 329357-001 Five-Input Vapor Sensor Interface Module Series 7943 Vapor Sensor <br /> 329399-001 Five-Input Groundwater Sensor Module 4SITE Series 7943 Groundwater Sensor <br /> 329956-001 Eight-Input Type A Sensor Interface Module 4SITE Series 7943 Discriminating Interstitial Sensor <br /> 329950-001 Six-Input Type B Sensor Interface Module 4SITE Series 7943 Discriminating Dispenser <br /> 330843-001 Six-Input Pressurized Line Leak Interface Series 8484 Pressurized Line Leak Detection System <br /> Module(One per console) Requires TLS-350 Plus version 7.0 or higher software <br /> 329356-004 Eight-Input Smart Sensor Module Series 857080 Mag Pan Sump Sensor <br /> Series 857280 Vacuum Sensor <br /> 332250-001 Seven Input Smart Sensor Module Same as above <br /> with Embedded Pressure Sensor <br /> HIGH-POWER COMPARTMENT(Limit eight per console,unless otherwise noted) <br /> 329359-001 Four-Relay Output Interface Module <br /> 329360-001 Two-Input/Two-Relay Output Interface Module <br /> 329999-001 Pump Sense Interface Module Accepts up to four inputs <br /> 330374-001 Three-Output Pressurized Line Leak Series 8484 Pressurized Line Leak Detection System <br /> Controller Interface Module(Two per console) Requires TLS-350 Plus version 7.0 or higher software <br /> COMMUNICATIONS COMPARTMENT(Lirnit three oe.r console,unless otherwise acted) <br /> 330149-002 SiteFax Interface Module Allows hookup to most remote facsimile,modem or teletype <br /> equipment.Requires TLS-350 Plus version 3.0 or higher software. <br /> 330566-001 RS-485/232 Dual Port Communications Module(Slot 4 only) <br /> 330148-001 RS-232 Interface Module with Auxiliary Port Provides two 25-pin D-connectors for data transmission to <br /> P.O.S.terminal,printing device or computer <br /> 329362-001 RS-232 Interface Module Provides a 25-pin D-connector for data transmission to <br /> P.O.S.terminal,printing device,or computer <br /> 330000-001 Remote Printer Interface Module Provides a 25-pin D-connector for data transmission <br /> to a remote serial printer <br /> 330883-001 WPLLD Communications Module <br /> (Maximum one per console) <br /> 330020-425 Ethernet—TCP/IP Communications module Provides connectivity to local and wide area networks(LAN/WANS) <br /> Specifications <br /> For more information call <br /> Operating Temperature Range 32°F to 118°F(0°C to 45°C) 1-888-561'7942 <br /> Storage Temperature Range 15°F to 118°F(10'C to 45'C) <br /> ellVEEDER-ROOT O 2006 Veeder-Root Company • 125 Powder Forest Drive • Simsbury,CT 06070 • USA <br /> Telephone:860-651-2700 • Fax:860-651-2719 • www.veeder.com <br /> VR 13679 P/N 0576047-022 Rev E VR 42006 Printed in USA <br />
The URL can be used to link to this page
Your browser does not support the video tag.