I
<br /> m
<br /> DRAINAGE:
<br /> I
<br /> D1 CONNECT TO PROPOSED STORM DRAIN STUB.
<br /> INV(PER PLANS)=17.93
<br /> CONTRACTOR TO VERIFY SIZE, INVERT, LOCATION AND PIPE
<br /> MATERIAL PRIOR TO ANY CONSTRUCTION.
<br /> INSTALL DROP INLET, JENSEN 2424 OR EQUAL, WITH
<br /> , . KRISTAR "FLOGARD° (OR APPROVED EQUAL) FILTER. F
<br /> a
<br /> LIMIT OF D3 REPLACE EXISTING MANHOLE COVER WITH STANDARD
<br /> IMPROVEMENTS --- -- O A-108 GRATE, WITH KRISTAR "FLOGARD" (OR APPROVED N
<br /> EQUAL) FILTER p
<br /> ^' D4 INSTALL "SAFEDRAIN" (OR APPROVED EQUAL) WITH FILTER
<br /> AND SHUT-OFF VALVE.
<br /> INSTALL C-900 PVC STORM DRAIN PIPE FROM CANOPY
<br /> DRAIN DOWN SPOUTS. SEE PUMP ISLAND PIANS. ADJUST
<br /> N89°44'04"W 186.00' -
<br /> LOCATION AS NECESSARY TO AVOID PETROLEUM LINES.
<br /> h
<br /> Dt o
<br /> j� SEWER:
<br /> 48LF 4"SS '® m ._-
<br /> N
<br /> o
<br /> `A 5-0.0100 DRAIN
<br /> CONNECT TO PROPOSED 6 SEWER STUB,
<br /> 0 GR=28.70 •� .' I S1 INV(PER PIANS) 22.59. CONTRACTOR TO VERIFY
<br /> 47LF 4"SS hNV-24.00 w PIPE SIZE, INVERT, AND LOCATION PRIOR TO a
<br /> S=0.0100 I o
<br /> ANY CONSTRUCTION.
<br /> vS2 o g^X - O INSTALL GREASE INTERCEPTOR, JENSON 1500 OR > _�T T
<br /> 'D.2 GINSTALLR283D.1.:: VJ6 - Oop INV(OUT)=23.32 R170INV(IN)=2157,
<br /> p S
<br /> CVS I s ' INV= OS - 4�LF-'4:53 CONSTRUCT COTG, INV=23.60, CONNECT TO
<br /> IMPROVEMENT I - ' S 0.0100 a° 53 GREASE WASTE LINE PER PLUMBING PIAN
<br /> LIMITS S4 . ..
<br /> ° G3
<br /> S4 CONSTRUCT COTG, INV=23.00, CONNECT TO
<br /> SANITARY SEWER LINE PER PLUMBING PLAN
<br /> .-.:, G12„G 2„G �U�NEER
<br /> S89`44'04°E NOTE: 4, b,
<br /> \ S 45LF 4'SS 4.16' S - ALL ON-SITE SEWER PIPE TO BE SDR-35 OR EQUAL �, SN oo
<br /> N69°44'047W 124.00' NsiALL D.I. D3 _ a
<br /> — — — — — -I s=aoloo D2 C
<br /> I -: GR=27.7
<br /> ® FL=18.6312") WATER: z° o
<br /> SD 5=0.0030 W1 8'" WATER SERVICE AND 8° FIRE SERVICE PER DEVELOPERS 15, 93 Ki`P w
<br /> 12"SD
<br /> _ .. ... QQ ".,62LF 12" PLANS. CONTRACT D
<br /> T VERIFY INSTALLATION, SIZE. a
<br /> ADEQUATE PRESSURE AND FLOW RATE PRIOR TO ANY ti
<br /> I CONSTRUCTION. z dj
<br /> I
<br /> INSTALL DOUBLE CHECK DETECTOR VALVE ASSEMBLY WITH N �
<br /> E]@ FIRE DEPARTMENT CONNECTION PER CITY STD. W-15
<br /> i
<br /> (P)SMT �
<br /> CONNECT TO FIRE C � ° •p a o _ 2' WATER METER FOR DOMESTIC SERVICE TO BE INSTALLED
<br /> •• RISER PER FIRE II II. W3 BY CIN OF MANTECA. LOCATION AND PROTECTION OF THE
<br /> \,' • • SPRINKLER PLAN WATER METER AND BACKFLOW DEVICE MUST BE APPROVED
<br /> BY THE CITY OF MANTECA WATER DEPARTMENT, 0
<br /> ` 'CONC v �1 2 WATER METER FOR IRRIGATION SERVICE 70 BE INSTALLED
<br /> y
<br /> 11 (Tt'P) - I - € ' 4 BY CITY OF MANTECA LOCATION AND PROTECTION OF THE z
<br /> N�� WATER METER AND BACKFLOW DEVICE MUST BE APPROVED MR F �
<br /> I00
<br /> °• < CID
<br /> BY THE CITY OF MANTECA WATER DEPARTMENT.
<br /> G3 WS Ct
<br /> INSTALL REDUCED PRESSURE BACKFLOW DEVICE PER CITY ®���'` o 0 0)
<br /> PROPOSED DS • ° . o ""- - STD. W-75. 0 00 U
<br /> ., MCDONALDS m mn. o O CONNECT HOT AND COLD WATER TO TRASH ENCLOSURE PER o w V
<br /> RESTAURANT/ n ro. v; W6 PLUMBING PLAN �o.. a ° Y
<br /> GAS STATION - v P' c o LIMIT OF o z m W
<br /> w FF=29.50'
<br /> Fjn � Ij.. �n IMPROVEMENTS ,�A Yom.._ o �" WoPAD=28.66' 2 �S ELECTRICAL: iW o �z LO I-
<br /> r
<br /> PROPOSED SURFACE MOUNTED TRANSFORMER. CONTRACTOR 0) O
<br /> roCq
<br /> 2„W - - E1 TO COORDINATE EXACT TRANSFORMER LOCATION, SERVICE , " �
<br /> v
<br /> a r
<br /> -'-'- - CONC N CONNECTION AND CONDUIT ROUTING WITH ELECTRIC x0 3:TANK COMPANY PRIOR TO ANY CONSTRUCTION. a
<br /> N ' SLAB= - °1 O_ O
<br /> w EXISTING PG&E JOINT POLE TO BE RELOCATED o O
<br /> a I ip E2 PER PLANS BY OTHERS. CONTRACTOR TO COORDINATE ;� w w O 01
<br /> • - REMOVAL WITH ELECTRIC COMPANY PRIOR TO ANY •� w o <
<br /> '' U7 - -- CONSTRUCTION. � " m 0 w
<br /> zo ¢ H
<br /> p p w O
<br /> TANK N O 2� GO
<br /> I u VENT N z ............ GAS: w m N Q
<br /> '( ?•: I GAS METER. • Sin 0 U O
<br /> G7
<br /> CONTRACTOR TO VERIFY BUILDING CONNECTION AND0 w LE ofCOORDINATE SERVICE LOCATION AND ROUTING WITH GAS z a
<br /> COMPANY PRIOR TO ANY CONSTRUCTION. VERIFY ADEQUATE °a' �3. < Q
<br /> a a o 0. O
<br /> PRESSURE AND FLOW RATE PRIOR TO ANY CONSTRUCTION.
<br /> z
<br /> © 2” GAS LINE TO BE STUBBED FOR THIS PROJECT. V. a a 01
<br /> CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION. s wCID
<br /> N
<br /> CONTRACTOR TO PLACE 2" GAS LINE TO BUILDING.
<br /> o h
<br /> GRAPHIC SCALE LIMY op I INsrALL D.ICN.
<br /> 20 0 10 20 a 80 MCDONALD'S FIRE SERVICE D4 GR=26,75 -
<br /> IMPROVEMENTS lig MAIN FL=18.90(18") NOTE:
<br /> ( IN FEET ) , . I 6 FS >. ' ;, ALL STORM DRAIN INLETS SHALL BE MARKED WITH THE CITY
<br /> = OF MANTECA STORM DRAIN MARKERS:
<br /> 1 inch 20 {t.
<br /> "NO DUMPING - DRAINS TO RIVER"
<br /> G2
<br /> I
<br /> I. _. WE ¢ O M
<br /> Q J
<br /> )0.66' I O Q N
<br /> - — — _ S89°44'047E 181 .84'
<br /> — FIRE LANE NOTE: N Of C) z O
<br /> EZ \PER PLA C BY OTIT- POLE WP ,W4 THE FOLLOWING METHODS OF FIRE LANE IDENTIFICATION ARE TAKEN FROM SECTION w
<br /> _ S89°44'04' E
<br /> PER PLANS BY OTHERS 488.06' R2 ,L�� •T 'p 22500.1 OF THE CALIFORNIA VEHICLE CODE AND ONE OF THE THREE METHODS Of } 0r U
<br /> • PRESENTED BELOW MUST BE PRESENT FOR ALL AREAS DESIGNATED AS A FIRE F Q CA
<br /> . _ .._ . _ .._.._ _ _ .. ._ .._ .. _. ACCESS LANE. Q Z
<br /> = o d
<br /> Ft,
<br /> ill T A. POSTING OF A SIGN EVERY 25' ALONG AND IMMEDIATELY ADJACENT TO. AND W I- U N E�
<br /> _._. _ _ ._
<br /> VISIBLE FROM, THE DESIGNATED FIRE LANE CLEARLY STATING IN LANE
<br /> NOT K _j Z
<br /> LESS THAN ONE INCH IN HEIGHT THAT THE PLACE IS A FIRE LANE AND NO J O
<br /> - — — — — — — — — — — — — — — — — — — _ _ PARKING IS PERMITTED OURADA ENGINEERING a w
<br /> — ---�- - B. BY OUTLINING OR PAINTING THE PAVEMENT REO WITH THE PAVEMENT PAINT N N Z
<br /> AND, IN CONTRASTING COLOR, MARKING THE PAVEMENT EVERY 25' WITH THEM Q rn C)
<br /> WORDS "FIRE LANE-NO PARKING' WHICH ARE CLEARLY VISIBLE FROM A 3177 SUNSET BLVD., SUITE L C) Q
<br /> VEHICLE. ROCKLIN, CALIFORNIA 96877 > LW
<br /> C. BY A RED CURB OR RED PAINT ON THE EDGE OF THE ROADWAY UPON 0
<br /> — - - - - -- - - - - - - _ _ _ _ _ _ WHICH IS CLEARLY MARKED EVERY 25' WITH THE WORDS "FIRE LANE-NO PHONE (918) 6241221 FAX (916) 6241232 Z O
<br /> PARKING" ON THE FACE OF THE CURB. Q CL
<br /> 689.65'(MON TO MON) '� ' SURVEY INFORMATION, OURADA ENGINEERING 5/02/2008 �
<br /> EIRE SERVICE NOTE: DRAWING, MC1414GRDWG OUT, UTILITY
<br /> UTILITY NOTE LATHR®O ROAD (6O ' IW)
<br /> THESE PLANS ARE NOT APPROVED FOR UNDERGROUND FIRE JOB NO., MC-1414 REVISED BY, ASM
<br /> THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES, PIPES _ +'. R` "@ a SERVICE INSTALLATION, THE INSTALLING CONTRACTOR SHALL
<br /> AND/OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A ,,. _ -.:: SUBMIT FOR APPROVAL A SCHEMATIC SHOP DRAWING �Y
<br /> SEARCH OF AVAILABLE RECORDS. THE CONTRACTOR SHALL ASCERTAIN - - SHOWING PART BY PART INSTALLATION ARRANGEMENT OF ALL
<br /> THE TRUE LOCATION OF ALL UNDERGROUND UTILITIES AND SHALL BE _ UNDERGROUND APPURTENANCES, INCLUDING CUT SHEETS AND
<br /> RESPONSIBLE FOR ANY AND ALL PUBLIC OR PRIVATE UTILITIES, SHOWN PARTS LIST WITH UL LISTING NUMBERS. FLAN
<br /> OR NOT SHOWN HEREON.
<br /> DATE: 06/25/200q � -
<br />
|