EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2012 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:40:59 PM
Creation date
11/20/2019 8:45:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2016
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department - =" <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 __ (� <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CRUISERS MANTECA#29 1 1137 W LATHROP RD, MANTECA August 25, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br /> where monitoring will be performed, all monitoring locations(included but not limited to smart sensors and liquid <br /> sensors) were not identified on the submitted map. Immediately log into the California Environmental Reporting <br /> System(CERS) at http://cers.calepa.ca.gov/and upload a copy of the complete and accurate UST Monitoring Site <br /> Plan. <br /> This is a Class II violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 8-19-2016 and an inspection report was issued on 8-20-2016 identifying information <br /> to be submitted to bring this site into compliance. This information was required to be submitted 30 days from receipt <br /> of the inspection report issued on 8-20-210. This information has not been received until 10-27-2016. An operator <br /> that receives an inspection report shall have 30 days to submit a written response that includes a statement <br /> documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> report. <br /> This is a Class II violation. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of accurate monitoring plans were not available for inspection. The monitoring plan(s) uploaded <br /> into CERS is not current and/or not approved by the EHD. The shut down information section for the UDC sensors <br /> for all tanks indicated "No' for the "UDC Leak Alarm Triggers Automatic Pump Shutdown" question. A copy of these <br /> plans shall be accessible on site at all times. Immediately locate and retain a current and accurate plan copy on <br /> site. <br /> This is a Class II violation. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> No person may own or operate an UST unless a permit for its operation has been issued by the local agency to the <br /> owner or operator of the UST system and all the operating conditions have been met. New Bravo Snap and Lock <br /> Sump Covers were installed at this site, a permit SR0073494 was obtained for this repair. This permit was approved <br /> for the installation of Bravo retrofit covers on fill sumps only, however, during the site inspection it was discovered that <br /> new Bravo Snap and Lock Sump Covers were installed on turbine as well as fill sumps. Emergency repairs relating <br /> to UST system monitoring and release detection may be performed by a properly licensed, trained, and certified <br /> contractor pursuant to the EHD'S policy and a permit obtained within one business day from the EHD. All other <br /> repairs must have a permit submitted to and approved by the EHD prior to beginning work. To date, no additional <br /> documentation was submitted to amend the existing permit SR0073494 with the correct scope of work. Immediately <br /> submit all appropriate documentation, as requested in the 7-14-2016 EHD permit inspection report. <br /> This is a Class II violation. <br /> Page 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.