My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2003 PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
INSTALL_2003 PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2019 8:28:11 AM
Creation date
11/21/2019 8:22:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003 PLANS
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VEEDER ROOT TLS-350 .PLUS <br /> TLS - 350 <br /> Ir TLS- 350 PLUS PANEL MONITORING SYSTEM EQUIPMENTTYPICASINSTALLATION <br /> �I NEW INSTALLATIONS: <br /> SEE SITE PLAN FOR LOCATION OF OVERFILL NOTE: WARNING: BE SURE AC POWER TO DESCRIPTION PART # <br /> ALARM AND ACKNOWLEDGEMENT SWITCH THIS DRAWING IS ONLY TO BE USED AS A GUIDE. FOR 19THE SYSTEM AND ANY ASSORTED TLS-350 PLUS CONSOLE WITH CONTINUOUS STATICAL 848290-022 <br /> SPECIFIC INSTALLATION INFORMATION YOU MUST USE THE ALARM CIRCUITS IS OFF BEFORE PROBE -► '=r2_ . _ . LEAK DETECTION & INTEGRAL PRINTER. CSLD# 330160-002 <br /> OPENING THE FRONT-PANEL <br /> VEEDER—ROOT SITE PREPARATION AND INSTALLATION COVER AND CONNECTING PROBE 0 a a a TLS-350 EXPANSION MODULE. 847490-001 <br /> OVERFILL MANUAL. AND SENSOR WIRES. IF HIGH PR INTERFACE MODULE FOUR-INPUT PROBE/THERMISTER INTERFACE MODULE. 329356-002 <br /> VOLTAGE IS SHORTED ACROSS <br /> ALARM ANY BARRIER TERMINAL, FOUR RELAY OUTPUT INTERFACE MODULE. 329359-001 <br /> 790091-001 NOTE: REFER TO THE N.E.C. HANDBOOK FOR EXPLOSION AND FIRE COULD <br /> SPECIFIC WIRING AND GROUNDING RESULT. • . . 8-INPUT INTERSTITIAL/LIQUID SENSOR INTERFACE MODULE. 329358-001 <br /> REQUIREMENTS OF ELECTRICAL PANEL. <br /> SITEFAX MODULE. (ORDERED WITH CONSOLE) 330149-002 <br /> OVERFILL ALARM SHALL ACTIVATE RED LIGHT SEN -► r-9 T:-2 _ + _ , r� + <br /> AUDIBLE AND VISUAL SIGNAL AT 1 ELECTRICAL PANEL ® ""� PROBE RISER CAP AND RING KIT. 312020-•952 <br /> 90% TANK CAPACITY. ]-�E ALARM BUZZER (CONNECTED TO) Q m m® m a m m s m m m <br /> 2 (STANDBY GENERATOR) WARNING: ALARM CANNOT BE USED FOR • • INTERSTITIAL SENSOR RISER CAP & ADAPTOR KIT, 2". 312020-928 <br /> FLOW CONTROL. ALARM RELAYS PROVIDE INTERFACE MODULE <br /> 3 w <br /> MAGNETOSTRICTIVE PROBE INSTALLATION KIT. (DIESEL) 849600-001 <br /> ONLY A MOMENTARY CLOSURE AND <br /> YELLOW LIGHT CANNOT ACTUATE FLOW CONTROL TLS-350 0.1 GPH MAGNETOSTRICTNE DIGITAL SENSING 847390-10"x" <br /> (ACKNOWLEDGE) DEVICES SUCH AS VALVES AND PUMP ® PROBE. <br /> MOTOR RELAYS. DO NOT CONNECT <br /> _ OUTPUT RELAYS TO A DEVICE THAT (X) INTERSTITIAL SENSOR FOR STEEL TANKS, 794390-420 <br /> ACKNOWLEDGEMENT DRAWS MORE THAN 2 AMPS! <br /> SWITCH (X) TLS-350 SUMP SENSORS 794380-208 <br /> 790095-001 115 VAC 115 VAC WARNING: DISCONNECT ALL POWER 0 OVERFILL ALARM 790091-001 <br /> CIRCUIT CIRCUIT BEFORE MAKING ANY CONNECTIONS <br /> 5 REAKER (BREAKER TO PREVENT DEATH, SERIOUS IN- ACKNOWLEDGEMENT SWITCH. 790095-001 <br /> JURY, EXPLOSION, OR ELECTRICAL <br /> OVERFILL TLS 350 ! PRINTER PAPER, FOUR-R011 PACKAGE. 514100-210 <br /> 4 ALARM MONITOR SHOCK. MONITOR MUST NEVER BE <br /> 3 OPERATED UNLESS THE FRONT <br /> COVER IS CLOSED OVER THE EXISTING TLS-350 INSTALLATIONS (TO BE UPGRADED) <br /> 2 N BARRIER TERMINALS IN THE IN <br /> TRiNSICALLY�-SAFE AREA. <br /> 1 G ® DESCRIPTION PART # <br /> SHIELDED CABLE MUST BE USED WHEN INPUT 2 RELAY TLS-35.0 SOFTWARE UPGRADE (REQUIRED IF EXISTING <br /> RESET r}`r' � '"� UNIT IS BEING RE--USED) NOTE: IF EXISTING TLS-350 <br /> BUTTON UTILIZING THE EXTERNAL INPUT ay.I IS BEING RE-USED, ENTIRE MONITORING SYSTEM TO <br /> m m m m m Q e e e m m Q • BE BROUGHT UP TO CURRENT STANDARDS. <br /> 1/0 00MBINA'RO1 4 1ODULE CONTINUOUS STATISTICAL LEAK DETECTION SOFTWARE 330160-002 <br /> ENHANCEMENTS <br /> OOVERFILL ALARM 790091-001 <br /> -� OVERFILL ALARM ACKNOWLEDGEMENT SWITCH 790095-001 <br /> MODULE EXPANSION BOARD 847490--001 <br /> NEU WARNING: EXPLOSION AND/OR 4-RELAY OUTPUT INTERFACE MODULE 329359-•001 <br /> EQUIPMENT DAMAGE COULD OCCUR <br /> AC LINE IF CONDUITS DO NOT ENTER THE TLS-350 TO TLS-350 PLUS UPGRADE KIT 331500-306 <br /> BARRIER TLS--350 MONITOR THROUGH THEIR <br /> CHASSIS DESIGNATED PREFORMED SITE FAX 330149-002 <br /> KNOCKOUTS. PROBE RISER CAP AND RING KIT. 312020-952 <br /> PVC COATED NO a TLS INTERNAL MODEM (SITE FAX) MAGNETOSTRICTIVE PROBE INSTALLATION KIT. (DIESEL) 849600--001 <br /> WARNING: DO NOT PERFORM DRILLING, FILING, RIGID CONDUIT NOTES: <br /> GRINDING AND TAPPING PROCEDURES IN A 1. WIRING TO PROBES AND TLS-350 0.1 GPH MAGNETOSTRICTIVE DIGITAL SENSING 847390-10"x" <br /> HAZARDOUS AREA. DRILLING, FILING, GRIND- SENSORS MUST BE BELDEN PROBE. <br /> ING AND TAPPING CAN CAUSE SPARKS AND BELDFOIL CABLE #837XX (16 AWG PRINTER UPGRADE: <br /> IGNITE VOLATILE FUMES AND LIQUIDS FOUND IN MIN.). NO EXCEPTIONS OR EQUALS <br /> A CLASS I, GROUP D HAZARDOUS LOCATION. ACKNOWLEDGT T <br /> CH 1 DOOR GROUP PRINTER & TAKE-UP 329370-004 <br /> FAILURE TO COMPLY COULD RESULT IN DEATH, INAL ACKNOMLEDGEMENI SWITCH TERMINAL #5 2. CONNECT WITH #12 AWG (OR LAR- COMMUCATION MODULE 329348-001 <br /> SERIOUS PERSONAL INJURY, PROPERTY LOSS GER) CONDUCTOR THE BARRIER <br /> AND EQUIPMENT DAMAGE. GROUND TO THE EARTH GROUND BUS IF EXISTING KEYPAD IS LIGHTBULB TYPE, REPLACE 329328-002 <br /> AT THE POWER DISTRIBUTION PANEL. WITH NEW LCD TYPE KEYPAD <br /> CAP & RING KIT <br /> #312020-878 SEE. NOTE 8 CAUTION: IT IS CRITICAL THAT 3, 0 DENOTES FIELD WRING CON- <br /> WEATHERPROOF JUNCTION BOX WITH 3/4 PIPING VAULT 4� YOU IDENTIFY AND MAINTAIN THE NECTION USING WATERPROOF CON- 1. PHONE JACK TO BE LOCATED WITHIN 3 FEET OF TLS PANEL. USE RJ11 OUTLET. <br /> 5' (2 WIRE) CABLE INCH NPT THDS (16 CUBIC INCH MINIMUM) SENSOR RELATIONSHIP OF PROBE AND NECTORS SUPPLIED WITH THE PROVIDE CONDUIT RUN PER SBC NETWORK ENGINEER REQUIREMENTS. CONTACT <br /> SUPPLIED WITH PROBE SEE NOTE 9 (TYP. OF 3) SENSOR LOCATIONS AND THEIR PROBE(S) AND SENSOR(S). OCS TO ENSURE PHONE LINE CAN DIAL LONG DISTANCE AND HAS FAX <br /> 2 CORD GRIP SEALS WIRES TO THEIR POSITIONS ON THE CAPABILITIES. <br /> 1 CORD GRIP SEAL FOR SUPPLIED WITH PROBE CORD GRIP SEALS SUPPLIED PROBE OR SENSOR CONNECTORS. 4. INTRINSICALLY SAFE WIRING SHALL 2 TANK ANNULUS MONITOR SENSOR TO BE WIRED TO CHANNEL 1 AND LABELED AS <br /> SENSOR <br /> SUPPLIED NTH 1-FOR RISER CAP WITH SENSORS 1-FOR RISER FAILURE TO DO SO COULD RESULT BE INSTALLED IN ACCORDANCE WITH SUCH ON TLS--350 PANEL. FILL RISER SUMP SENSOR TO BE WIRED TO CHANNEL <br /> SENSOR 1•--FOR J-•BOX CAP, 1-FDR J-BOX IN THE IMPROPER IDENTIFICATION ARTICLE 504-20 OF THE NEC ANSI/ 2 AND LABELED AS SUCH ON CONTROL BOX. PRODUCT SUPPLY PIPING SUMP <br /> GRADE OF A LEAK LOCATION OR LEAK NFPA 70, 1990. <br /> TYPE. APPENDIX A PROVIDES A SENSOR TO BE WIRED TO CHANNEL 3 AND LABELED As SUCH ON TLS-350 PANEL. SW 1040 <br /> 5. TO MAINTAIN INTRINSIC SAFETY AND PIPING VAULT SENSOR, IF REQUIRED, TO BE CHANNEL 4. <br /> - FORM TO RECORD THE COLOR PROPER SYSTEM OPERATION, PROBE <br /> CODING OR LABELING METHOD AND SENSOR WIRING MUST BE REVISIONS / AUTHORIZATIONS <br /> USED TO IDENTIFY THE WIRING INSTALLED WITHIN SEALED CONDUIT. <br /> WHITE + RIGID CONDUIT SCHEME. 6 NO. RMW / AUTHORIZATIONS DATE BY <br /> BLACK - 2 1/2" THREADED PVC . ELECTRICAL RATING POWER INPUT - 120 <br /> SUMP SENSOR -11 oe SENSOR(+ CAP HAND TIGHT ONLY. PROBE + VAC, 50/60 HZ, 600 WATTS MAXIMUM. Q MASTER DRAWINGS 3/4/03 <br /> SENSOR(-� OBE 7. INCREASE THIS I �>! tz 03 <br /> FILL CONTAINMENT SUMP SENSOR +� RISER 20" MIN PIPING VAULT IN GENERATOR E IS M NIMUM DIMENSION IF 1 PER CLIENT INSTRUCTIONS / 1 DM <br /> SUMP THE TANK DIAMETER DOES NOT MATCH THE <br /> SUMP SENSOR SEE.NOTE 7 ROOM (IF APPLICABLE) <br /> 2 <br /> 1/2- DIAMETER RISER. ANNULAR SPACE PROBE LENGTH. EXAMPLE: A 7'6" DIA TANK 2 UPDATED TO 01/23/04 STANDARDS 2/23/04 DW <br /> / ANNULAR SPACE WILL USE AN 8' PROBE. THE EXTRA PROBE <br /> I .. .d .. .. . . .. .. . SUMP SENSOR + HEIGHT WILL. RESIDE IN THE RISER PIPE <br /> LEADER CABLE OF SUMP SENSOR WHICH MUST BE 6" LONGER THAN THE 20" <br /> INTERSTITIAL SENSOR MIN IN ORDER TO PROVIDE ROOM. PROPRIETARY SBC INFORMATION <br /> SUMP SENSOR 8. THE TOP OF THE RISER PIPE MUST BE NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> (+} THIS INFORMATION MAY ONLY BE USED BY AUTHORIZED PERSONNEL OF <br /> SUMP SENSOR THREADED TO ACCEPT A 4" ADAPTER RING. IN THE LOCAL. GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> .:. ADDITION, MAKE SURE THERE WILL BE PERMITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, AND/ OR <br /> ENOUGH CLEARANCE BETWEEN THE TOP OF ZONING CHANGES. <br /> ..............: WARNING: EXPLOSION COULD OCCUR IF OTHER THE INSTALLED RISER CAP AND MANHOLE <br /> WIRES SHARE CONDUITS OR TROUGHS WITH COVER TO ALLOW ROOM FOR THE TWO-WIRE DRAWINGS PREPARED FOR <br /> PROBE OR SENSOR WIRING. CONDUITS AND PROBE CABLE TO PROTRUDE FROM THE CAP. <br /> "' "' WRING TROUGHS FROM TLS-350 PROBES AND INSTALL A STANDARD ADAPTER RING AND <br /> SENSORS MUST NOT CONTAIN ANY OTHER WIRES. RISER CAP ON THE RISER PIPE. CORPORATE <br /> .......... TO TLs-350 REAL ESTATE <br /> - TO MAINTAIN INTRINSIC SAFETY, PROBE AND NOTE: THE CAP SHOULD BE A LOCKING CAP, <br /> SENSOR WIRING MUST BE INSTALLED WITHIN SEALED "EVERTITE" OR EQUIVALENT, WITH A STANDARD <br /> �--�-� �� �---- `--- :_^; :_•;- CONDUIT. PROBE AND SENSOR WIRING MUST NOT RING ADAPTER. THE CAP MUST BE DRILLED <br /> BE ROUTED IN THE SAME CONDUIT AS ANY OTHER AND TAPPED TO RECEIVE THE FURNISHED <br /> -_------ --- WIRING. IF A WIRING TROUGH IS USED FOR PROBE CABLE GRIP. KITS CONSISTING OF A 4-INCH ED tri <br /> AND SENSOR WIRES, NO OTHER WIRING CAN USE CAP, ADAPTER RING AND PLUG FOR THE CAP E S CALON <br /> THE SAME TROUGH. KEEP PROBE AND SENSOR ARE AVAILABLE FROM VEEDER-ROOT. FOR EACH <br /> RUPTURE WIRES SEPARATED FROM ALL OTHER WIRING. PROBE RISER, ORDER ONE KIT NUMBER: <br /> Y BASIN DAY312020-952 (CAPACITANCE & MAGNETO- 1 81 2 COLEY AVENUE <br /> E <br /> K <br /> IF LESS THAN 2.13" STRUCTIVE PROBES. <br /> ._----------------- <br /> ^Y^-= ;:: ='; (BY OTHERS) USE MICRO SENSOR CAUTION: IMPROPER SYSTEM OPERATION WILL ESCALON, CALIFORNIA <br /> - RESULT IF PROBE AND SENSOR WIRING FROM 9. WEATHERPROOF JUNCTION BOX NTH 1/2 <br /> "= - -� -----' -- � <br /> ;;;•.._.:;.-: SEPARATE TLS-350 MONITORS SHARE THE SAME INCH NPT THDS (16 CUBIC INCH MINIMUM) CLLC=ESCLCAII UG-010 <br /> ---------------____ ....-.............. CONDUIT. DO NOT RUN PROBE AND SENSOR WIRING SEALOFFS MUST BE INSTALLED PER NFPA <br /> FROM SEPARATE TLS-350 SYSTEMS IN THE SAME SPEC. SHEET TITLE: <br /> a VEEDER-ROOT OR VEEDER-ROOT CONDUIT. UNDERGROUND FUEL TANK <br /> INTERSTITIAL SUMP SENSOR MICRO SENSOR SUCTION SYSTEM <br /> SENSOR #794380-20 #794380-340 TLAS SENSORS MAY BETE: WRING FROM RUNTHE TE TLS PARES AND <br /> MOETYPICAL TLS-350 INSTALLATION <br /> CONDUITS OR TROUGHS PROVIDING THEY ARE TIHO IS A SCHEAAAM ENGAGpMENT NUMBER: DATE: 09/16/03Iiii: AS NOTED <br /> NOTE< POWERED BY THE SAME MONITOR. MOVMD BY VEEDER_�T� <br /> PROGRAMMING PROTOCOL - 1) LEVEL PROBE TO ALARM 0 90%, CONSULTING ENGINEERS DRAWN BY- DW CHECKED ar: TP <br /> 2) HIGH LEVEL TO ALARM 0 957., MAX VOLUME TO ALARM 0 100% LEAK SENSOR LOCATION WITH DAY TANK (IF APPLICABLE) TM DMWMNG B NOT sM 2880 Sunrise Boulevard sgc AUTH0RIZOSHEET: 7 oF: 8 SHEETS SHEET No. <br /> SPE011191C Suite 206 <br /> Rancho Cordova, CA 95742 SBC DRAWING NO.: <br /> TAT & ASSOCIATES, INC. (916) 635-2444 F7 <br /> (916) 635-2606 Fax <br />
The URL can be used to link to this page
Your browser does not support the video tag.