My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006536 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WOODBRIDGE
>
3824
>
2600 - Land Use Program
>
PA-0700180
>
SU0006536 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2019 2:36:10 PM
Creation date
11/22/2019 2:28:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0006536
PE
2632
FACILITY_NAME
PA-0700180
STREET_NUMBER
3824
Direction
E
STREET_NAME
WOODBRIDGE
STREET_TYPE
RD
City
ACAMPO
APN
01322052
ENTERED_DATE
4/25/2007 12:00:00 AM
SITE_LOCATION
3824 E WOODBRIDGE RD
RECEIVED_DATE
4/24/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
New Moose Lodge Soil Suitability Study Page 7 of 9 <br /> Our Project Number: E07175A <br /> November 5, 2007 <br /> 6.5 Percolation Test Procedure <br /> Percolation tests were conducted for the borings on October 30, 2007 in accordance with the <br /> requirements of the EHD. A percolation test with a duration of four hours was performed for <br /> each hole. The last half an hour of each test was observed by Lisa Medina, Senior Registered <br /> Environmental Health Specialist, EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on <br /> the PVC casing using an electric well sounder with an depth accuracy of 1/100th foot. All <br /> tabulated values on the field data sheet (appendix) are in decimal feet. After water drop was <br /> observed, the holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) <br /> of water above the bottom level of the percolation test hole. The readings were taken every 30 <br /> minutes for a period of four hours. <br /> 6.6 Percolation Test Forms and Results <br /> The completed percolation test form is included in the appendix of this report. <br /> A shallow percolation test is defined by the EHD as being between 36 and 42 inches in depth; a <br /> satisfactory percolation rate for a shallow test is less than or equal to 60 minutes per inch drop. <br /> A deep percolation test is defined as being between 3.5 and 25 feet in depth; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. One percolation test must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field of each parcel to <br /> utilize a standard septic system. Details of the percolation tests are summarized in the table <br /> below. <br /> Table S. <br /> Sum ary of Percolation Tests <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P-1 (shallow) 3.30 6.4/ 4 hr. Satisfactory perc. rate <br /> 10-30-07 <br /> P-1 (deep) 5.80 19.2,/ 4 hr. Satisfactory perc. rate <br /> 10-30-07 <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> A satisfactory percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> 6.7 Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas of the site have demonstrated a satisfactory <br /> percolation rate in accordance with the requirements of the EHD for the use of a standard <br /> septic system. <br /> '404 <br /> 902 Industrial Way•Lodi,CA 95240.209.367.3701 •Fax 209.369.4228 ©2007 Neil O.Anderson&Associates,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.