My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:04:34 PM
Creation date
11/25/2019 8:30:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoriug System Certification REC ]VED <br /> eco <br /> NOV 2 0 2015 (GO-C111.COWAIANC[ <br /> D. Results of Testing/Servicing ENVIRONMENTAL <br /> Software Version Installed: 333.02 HEALTH DFPARTMFNT <br /> Complete the following checklist: <br /> E Yes ❑ No* Is the audible alarm operational? <br /> E Yes ❑ No* Is the visual alarm operational? <br /> E Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> E Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br /> E N/A operational? <br /> ® l cs ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) E Sump/Trench Sensors; E Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? E Yes; ❑No. <br /> E Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e.' no <br /> ElN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 90% <br /> ❑ Yes* E No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> E Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; E Water. If yes,describe causes in Section E,below. <br /> E Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> E Yes ❑ No* 1 Is all monitoring equipment operational per manufacturer's specifications? <br /> x In Section E below,describe how and when these deficiencies were or will be corrected. <br /> �r ( -� <br /> E. Comments: Small amount of water was found in both diesel STP sumps and the water was removed during <br /> the inspection.Addition 36he following equipment is connected to the rponitoring system: <br /> 1.Veeder Root—794380-304 Sensor monitoring the 87 Piping Sump Annu a <br /> 2.Veeder Root—794380-304 Sensor monitoring the 91 Piping Sump Annu lar <br /> 3.Veeder Root—794380-304 Sensor monitoring the Diesel Piping Sum Annu ar <br /> 4.Veeder Root—794380-304 Sensor monitoring the 87 Fill Sump Annu ar <br /> 5.Veeder Root—794380-304 Sensor monitoring the 91 Fill Sump Annu lar <br /> 6.Veeder Root—794380-304 Sensor monitoring the Diesel Fill Sump Annu lar. <br /> 7.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#1/2 Annua ar <br /> 8.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#3/4 Annualar <br /> 9. Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#5/6 Annualar <br /> 10. Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#7/8 Annualar <br /> 11.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#9/10 Annualar <br /> 12.Veeder Root—794380-304 Sensor monitoring the Under Dispenser Containment#11/12 Annualar <br /> 13.Veeder Root—794380-304 Sensor monitoring the Vent Sump Annular <br /> 14.Veeder Root—794380-304 Sensor monitoring the Vent Sump-All additional sensors were tested. <br /> Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.