Laserfiche WebLink
REGEAVEL . <br /> NOV � v 2013 MONITORING SYSTEM CERTIFICATION PCV <br /> For Use By All Jurisdictions Within the State of California ECO•CNEK COUPL4NU <br /> EN��V��I��Fi�-V�ppter 6.7, Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> -17EP E <br /> is'TorHm�mus a used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: ARCO Bldg.No.: <br /> Site Address: 550 W.Valpico Road City: Tracy,CA Zip: 95376 <br /> Facility Contact Person: Edgar Rizkalli Contact Phone No.: (925) 548-7910 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 10/28/2015 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: #1 87 20 000 Gal Tank ID: #2 91 12 000 Gal <br /> ®In-Tank Gauging Probe. Model: MAGA ®In-Tank Gauging Probe. Model: MAGA <br /> ®Annular Space or Vault Sensor. Model: 794380-301 ®Annular Space or Vault Sensor. Model: 794380-301 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ®Fill Sump Sensor(s). Model: 794380-208 ®Fill Sump Sensor(s). Model: 794380-208 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: VR Series 8484 ®Electronic Line Leak Detector. Model: VR Series 8484 <br /> ®Tank Overfill/High-Level Sensor. Model: VR Overfill Alarm ®Tank Overfill/High-Level Sensor. Model: VR Overfill Alarm <br /> ®Other(specify equipment type and model in Section E on Page 2). ®Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: #3 Diesel 10 000 Gal Tank ID: <br /> ®In-Tank Gauging Probe. Model: MAGA ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794380-301 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model: 794380-208 ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: VR Series 8484 ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: VR Overfill Alarm ❑Tank Overfill/High-Level Sensor. Model: <br /> ®Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 34 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s), ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser 1D: 7-8 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ®System set-up ® Alarm history report <br /> Technician Name(print): Nikola Zagorov Signature: Nro✓ <br /> Certification No.: Veeder Root Level 4#A32784 License.No.: 958763 A <br /> Testing Company Name: ECO-CHEK Compliance, Inc. Phone No.:(888) 500-CHEK <br /> Testing Company Address: P.O. Box 1394, Lafayette,CA 94549 Date of Testing/Servicing: 10/28/2015 <br /> Page 1 of 6 <br /> Rev(2/08) <br />