'4"FORCEMAIN SYSTEM DISTRIBUTION BOX 4"FORCEMAIN SYSTEM DISTRIBUTION BOX <br /> 2"FORCEMAIN SYSTEM 2"FORCEMAIN SYSTEM <br /> APPROXIMATE TEST LOCATION 2,000 GAL SEPTIC TANK <br /> Llra T <br /> 2,000 GAL SEPTIC TANK APPROXIMATE TEST LOCATION <br /> I <br /> CURRENT LEACH FIELD CURRENT LEACH FIELD <br /> (765SF+765SF (765SF+765SF <br /> REPLACEMENT AREA) REPLACEMENT AREA) <br /> FUTURE LEACH FIELD IF FUTURE LEACH FIELD IF <br /> BUILDING USE CHANGES BUILDING USE CHANGES <br /> (4,370SF+4,370SF (4,370SF+4,370SF <br /> REPLACEMENT AREA) REPLACEMENT AREA) <br /> 218.5' 218.5' <br /> BUILDING A BUILDING B <br /> 124,596 SF 124,596 SF <br /> 40' 10' 40' 10' <br /> I <br /> I <br /> i <br /> I i <br /> LEGEND FUTURE USE LEACH FIELD CALCULATIONS <br /> BUILDINGS A AND B: <br /> FUTURE LEACH FIELD OCCUPANCY PER ARCHITECTURAL DRAWINGS:250 EACH BUILDING <br /> FLOW:7.5 GAL/PERSON/DAY <br /> ---- PROPERTY LINE ADF PER BUILDING: 1,875 GPD <br /> FILTERBED SIZE:0.43 GAL/SF/DAY=4,361 SF <br /> TOTAL AREA REQUIRED INCLUDING REPLACEMENT:8,722 SF(4,361 X 2) <br /> (o <br /> 0' 50' 100' <br /> FUTURE LEACH FIELD AREAS FOR <br /> BUILDING USE CHANGE SCALE: 1"=100' <br /> ON SIEGFRIED 9/25/2019 <br />