My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012656
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEBER
>
1325
>
3500 - Local Oversight Program
>
PR0545007
>
ARCHIVED REPORTS_XR0012656
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2019 5:31:51 PM
Creation date
12/3/2019 4:50:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012656
RECORD_ID
PR0545007
PE
3528
FACILITY_ID
FA0025604
FACILITY_NAME
CATELLUS DEVELOPMENT PROPERTY
STREET_NUMBER
1325
Direction
W
STREET_NAME
WEBER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
CURRENT_STATUS
01
SITE_LOCATION
1325 W WEBER AVE
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
914
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 <br /> jj� MEN in 1—cm <br /> .'i <br /> -rraGar Aosearch Corporation <br /> �A f <br /> QUALITY ASSURANCE/QUALITY CONTROL PROCEDURES <br /> Tracer Research Corporation's normal quality assurance procedures were (allowed <br /> in order to prevent any cross-contamination of soil gas samples. <br /> Steel probes are used only once during the day and then washed with high <br /> pressure soap and hot water spray or steam-cleaned to eliminate the <br /> Possibility for cross-contamination. Enough probes are carried on each van <br /> to avoid the need to reuse any during the day. <br /> Probe adaptors (steel reducer and tubing) are used once during the course <br /> of the day and cleaned at the end of the each working day by baking in the <br /> GC oven. The tubing is replaced periodically as needed during the job to <br /> insure cleanliness and good fit. <br /> Silicone tubing (connecting the adaptor to the vacuum pump; s replaced <br /> as needed to insure proper sealing around the syringe needle. This tubing <br /> does not directly contact soil gas samples. <br /> Polyethylene tubing used to collect water samples is used one then <br /> discarded to prevent cross contamination of water samples. <br /> k Glass sy,inges are usually used for only one sample per day and are <br /> washed and baked out at night. If they must be used twice, they are purged <br /> with carrier gas (nitrogen) and baked out between probe samplings. <br /> Septa through which soil gas samples are injected into the chromatograph <br /> are replaced on a daily basis to prevent possible gas leaks from the <br /> chromatographic column. <br /> Analytical instruments were calibrated each day by analytical standards <br /> from Chem Service, Inc. Calibration checks are also run after approximately <br /> - -------every five-sOil--as-sampling-locat ions, - <br /> 2 cc subsampling syringes are checked for contamination prior to sampling <br /> each day by injecting nitrogen carrier gas into the gas chromatograph. <br /> Prior to sampling each day, system blanks are run to check the sampling <br /> apparatus (probe, adaptor, 10 cc syringe) for contamination by drawing <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.