Laserfiche WebLink
f a <br /> } Tracer Research Corporation <br /> i <br /> �M�u <br /> g.t <br /> s ambient air from above ground through the system and comparing the <br /> analysis to a concurrently sampled air analysis. <br /> All sampling and 2 cc subsampling syringes are decontaminated each day ` <br /> and no such equipment is reused before being decontaminated. Microliter <br /> size subsampling syringes are reused only after a nitrogen carrier gas blank <br /> is run to insure it is not contaminated by the previous sample. <br /> ...F Soil gas pumping is monitored by a vacuum gauge to insure that an <br /> adequate gas flow from the vadose zone is maintained. A reliable soil gas <br /> sample can be obtained if the vacuum prevure is 2 in. Hg less than the <br /> maximum pump capacity,which corresponds to an evacuation rate of >0.002 <br /> cfm. <br /> s..R <br /> 6 <br />