Laserfiche WebLink
I <br /> analysis VOA vials,with"Teflon"septa,are used as sample <br /> soil sampling at desired intervals. Soil samples are collected ys <br /> by either hammering(with a 14C)-pound drop hammer)or <br /> containers. <br /> hydraulically pushing a conventional split-barrel sampler.. The groundwater sample is decanted into each VOAviat in. <br /> containing pre-cleaned 2-inch-diameter brass tubes. A <br /> geologisJt or engineer from Apex Emirotech,Inc.,continuously such a manner that there is no meniscus at the tap of the vial. <br /> lags each borehole during drilling and constantly checks dri[1 A cap is quickly secured to the top of the vial. The vial is then <br /> inverted and gently tapped to see if air bubbles are present. It <br /> cuttings for indications of both the first recognizable <br /> none are present,the vial is labeled and refrigerated far <br /> occurrence of groundwater and volatile hydrocarbons using delivery,under strict chain-of-custody,to the analytical <br /> either a portable photoionization detector,flame ionization ry <br /> etween laboratory. label information should include a unique sample <br /> detector,or an explosimeter. The sampler is rinsed bidentification number,jab identification number,date,time,type <br /> samples and either steam cleaned or washed with all other � <br /> drilling equipment between borings to minimize the potential for of analysis requested,and the samplers name. <br /> cross-contamination. j <br /> For quality control purposes,a duplicate ureter sample is <br /> Monitoring wells are cased with threaded,factory-perforated collected from each well. This sample may also be analyzed or <br /> and blank Schedule 40 PVC. The perforated interval consists put on hold at the laboratory. When required,a trip blank. <br /> of slotted casing,generaily with 0.020-inch wide by 1.5-inch prepared at the laboratory,is placed in the transport cooler. It <br /> long slots,with 42 slots per foot. A PVC cap may be secured is labeled similar to the well samples,remains in the cooler <br /> to the bottom of the casing with stainless steel screws;no during transport,and is analyzed by the laboratory along with <br /> solvents or cements are used. Centering devices may be the groundwater samples. In addition,a field blank may be <br /> fastened to the casing to ensure even distribution of filter prepared in the field when sampling equipment is not <br /> material and grout within the borehole annutus. The well dedicated. The field blank is prepared after a pump or bailer <br /> casing is thoroughly washed and/or steam cleaned,or may be has been either steam cleaned or properly washed,prior to use <br /> purchased as pre-cleaned,prior to installation. in the ne)d well,and is analyzed along with the other samples. <br /> The field blank analysis demonstrates the effectiveness of the <br /> After setting the casing inside the hollow-stem auger,sand or in-field cleaning procedures to prevent cross-contamination. <br /> gravel fitter material is poured into the annular space to fill from <br /> boring bottom to generally 1 foot above the perforated interval: To minimize the potential for cross-contamination between otj <br /> A 1-to 2-foot thick bentonite plug is set above this filter material welts, <br /> lt ltold well development <br /> s either and <br /> water <br /> steam sampling <br /> acleaned for properlyequipment ted i <br /> to prevent grout from infiltrating the fixer pack Either neat <br /> cement,containing about 5 percent bentonite,or sand-cement between use. As a secondary precautionary measure,wells <br /> grout is then tremmied into the annular space from the top of are sampled in order of least to highest concentrations as <br /> the bentonite plug to near surface. A traffic-rated vault is established by available previous analytical data, f <br /> installed around each wellhead for wells located In parking lots In the event the water samples canna be submitted to the <br /> or driveways,while steel"stovepipes"are usually set over <br /> wellheads In landscaped areas. analytical laboratory on the same day they are collected(e.g., <br /> r due to weekends or holidays),the samples are temporarily <br /> After installation,the wells are thoroughly developed to remove stored until the first opportunity for submittal either on water ice <br /> residual ddlling materials from the wellbore,and to improve well in a cooler,such as when in the field,or in refrigerator at f. <br /> performance by removing Cine material from the filter pack that Apes office, <br /> may pass into the well. Well development techniques used <br /> may include pumping,surging,bailing,swabbing,jetting, SOP - 12 <br /> (tushing,and air-lifting. All development water is collected MEASURING LIQUID LEVELS USING <br /> either in drums or tanks for temporary storage,and properly WATER LEVEL'METER OR ]INTERFACE. <br /> disposed of depending on laboratory analytical results. To PRO13E t <br /> minimize the potential for cross-contamination between wells, <br /> all development equipment is either steam cleaned or properly Field equipment used for liquid-level gauging typically includes <br /> washed prior to use. f=ollowing development,the well is the measuring instrument(water-level meter or Interface probe) <br /> allowed to stand undisturbed for a minimum of 24 hours before and product bailer(s). The field kit also includes cleaning <br /> its first sampling. supplies(buckets,solution,spray bottles,and deionized water) <br /> to be used in cleaning the equipment between wells. <br /> SOP - 7 <br /> GROUNDWATER PURGING AND Prior to measurement,the Instrument tip is lowered Into the well <br /> SAMPLING until it touches bottom. Using the previously established top-of- <br /> casing or top-of-box(i.e.,wellhead vauik)point,the probe cord <br /> Prior to water sampling,each well is purged by evacuating a (or halyard)is marked and a measuring tape(graduated In <br /> minimum of three wetted well-casing volumes of groundwater. hundredths of a foot)is used to determine the distance <br /> When required,purging will continue until either the discharge between the probe end and the marking on the cord. This <br /> water temperature,conductivity,or pH stabilize,a maximum of measurement is then recorded on the liquid-level data sheet as <br /> ten wetted-casind volumes of groundwater have been the"Measured Total Depth"of the well. <br /> recovered,or the well is bailed dry. When practical,the <br /> groundwater sample should be collected when the water level When necessary in using the Interface probe to measure liquid <br /> In the well recovers to at least 80 percent of its static level. levels,the pr6be is first electrically grounded to either them" <br /> stove pipe or another metal object nearby. When no ground Is,. <br /> The sampling equipment consists of ether a"Teflon"bailer, available,reproducible measurements can be obtained by <br /> PVC bailer,or stainless steel bladder pump with a'Teflon" clipping the ground lead to the handle of the interface probe <br /> bladder. If the sampling system is dedicated to the well,then caSa• <br /> the bailer is usually"Teflon,"but the bladder pump is PVC with <br /> a polypropylene bladder. In general and depending on the <br /> intended laboratory analysis,40-milliliter glass,volatile organic <br /> SOP- Monitoring Wells <br />