Laserfiche WebLink
lw <br /> ec0100 and elIAMIment,inc. <br /> 4. Analytical Data <br /> Laboratory analytical results for VOCs analyses are presented in Table 3 in Appendix C. The <br /> complete laboratory analysis data reports for all samples are contained in Appendix D. <br /> 4.3 Summary and Discussion of Groundwater Results <br /> Groundwater samples were collected from boring locations EC2-01, EC2-02, EC2-04, EC2-05, <br /> EC2-06, EC2-07, EC2-08, EC2-09, and EC2-10. At boring locations EC2-03 and EC2-12, no <br /> groundwater was encountered in the drilled borings; and therefore, no groundwater samples were <br /> collected. A Geoprobe® Systems drill rig was used to drill to groundwater at approximately 56 <br /> feet bgs at each boring location. Groundwater samples were analyzed for TPH-g, TPH-mo, TPH- <br /> d and VOCs. Groundwater analytical results for the TPH and VOCs are presented in Tables 4 <br /> and Table 5, respectively(Appendix Q. <br /> 4.3.1 Analytical Results for TPH in Groundwater <br /> TPH-g was detected in two groundwater samples above the laboratory reporting limit. TPH-g <br /> was detected at boring location EC2-02 at a concentration of 29 micrograms per liter(gg/L) and <br /> boring location EC2-09 at a concentration of 120 gg/L, which is above the site-specific action <br /> level established for this assessment of 100 gg/L. TPH-mo was not detected in groundwater <br /> samples collected at the site above the laboratory reporting limit. TPH-d was detected in <br /> groundwater samples from nine of the ten boring locations sampled. Only at boring location <br /> EC2-08 was TPH-d not detected above the laboratory reporting limit. TPH-d was detected at <br /> concentrations ranging from 160 gg/L at boring location EC2-10 to 8,500 µg/L at boring location <br /> EC2-01, which are all above the site-specific action level established for this assessment of 100 <br /> µg/L. The laboratory detection limits varied significantly for TPH-mo analysis due to a high <br /> concentration of sediment in the water samples that required dilution of the sample. In several <br /> instances the laboratory detection limit was higher then the site-specific action level for that <br /> analyte. Laboratory analytical results for TPH analyses are presented in Table 4 in Appendix C. <br /> Figure 4 (Appendix A) shows contaminant concentrations for samples where a screening level <br /> was exceeded. Complete laboratory analytical reports for all samples are contained in Appendix <br /> D. <br /> 4.3.2 Analytical Results for VOCs in Groundwater <br /> VOCs were generally not detected at concentrations above the laboratory reporting limit in <br /> groundwater samples collected at the site. Benzene was detected at boring locations EC2-02 and <br /> EC2-09 at concentrations of 0.00023 mg/L and 0.00057 mg/L respectively, which are below the <br /> site-specific action level established for this assessment of 0.001 mg/L. Toluene was detected at <br /> seven of the nine boring locations sampled for groundwater at concentrations ranging from <br /> 0.00011 mg/L to 0.00042 mg/L, which are below the site-specific action level established for this <br /> assessment of 0.04 mg/L. Ethylbenzene was only detected at boring location EC2-02 at a <br /> concentration of 0.00012 mg/L, which are below the site-specific action level established for this <br /> assessment of 0.03 mg/L. m,p-Xylene was detected at boring location EC2-02 at a concentration <br /> of 0.000 18 mg/L, which is below the action level of 0.02 mg/L for xylene. Methyl tert-butyl ether <br /> (MTBE) was detected at boring location EC2-09 at a concentration of 0.084 mg/L, which is <br /> above the site specific action level established for this assessment of 0.005 mg/L. Methylene <br /> chloride was detected at boring location EC2-07 at a concentration of 0.000 11 mg/L, which is <br /> below the site-specific action level established for this assessment of 0.005 mg/L. 1,2- <br /> Dichloroethane (1,2-DCA) was detected at boring location EC2-09 at a concentration of 0.0049 <br /> 4-3 <br />