My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2011 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 11:53:49 AM
Creation date
12/16/2019 11:27:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2018
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fforda-Te 416 20'Street Phone:(209)744-0112 <br /> Galt,Ca 95632 Fax: (209)744-0116 <br /> afforda@)softcom.net <br /> E.O. VR-202 <br /> Veeder-Root In-Station Diagnostics Vapor Pressure Sensor Reference Test & <br /> Site Shutdown Test Report Form <br /> Permit Number:N-388 Test Company:AFFORDA-TE$T <br /> Site Name:PACIFIC SERVICE STATION Technician: ZANE NIMMO <br /> Site Address:6131 PACIFIC AVE Certification Number Expiration Date <br /> City: STOCKTON, CA Zip: 95207 District:#0083 <br /> Date/Time of Test:8/28/2018 Veeder-Root:A28446 7/28/18 <br /> VAPOR PRESSURE SENSOR UST PRESSURE TEST <br /> Calibration date for digital manometer(must be within 12 months of the test) 7/13/2018 <br /> Ending value for digital manometer drift test(must be 0.01 in.w.c.or less) .00 <br /> Digital manometer ullage pressure,inches of water column(in.w.c.) 1.96 <br /> TLS console pressure sensor value,inches of water column(in.w.c.) 1.890 <br /> Is pressure value between-0.20 and+0.20 in.w.c.? PASS <br /> VAPOR PRESSURE SENSOR AMBIENT REFERENCE TESTI,' <br /> Pressure sensor located at dispenser number(s) 5 / 6 <br /> Pressure sensor number 3 5 8 2 <br /> Non-calibrated pressure sensor value, inches of water column(in.w.c.) -0.056 <br /> Is pressure value between-0.20 and+0.20 in.w.c.? PASS <br /> SITE SHUTDOWN TESTS <br /> Test Parameter Test Result(Y/1) <br /> Was power removed from the TLS-350 console? Y <br /> Was power to the submersible pump(s)removed by the TLS-350? Y <br /> Was power restored to TLS-350 console? Y <br /> COMMENTS (Include Description of Repairs Made) <br /> NOTES: lValve must he returned to normal operating position after testing is completed. <br /> 2The ambient reference port cap must be in place after testing is completed. <br /> 'A certified Veeder-Root technician must perform this test. <br /> I declare, under penalty ofperjury under the laws of the state of California that based on information and belief formed <br /> after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br /> Signature of Technician: Date: 8/28/2018 <br /> Ver. 13—08.07.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.