My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2011 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 11:53:49 AM
Creation date
12/16/2019 11:27:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2018
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI RECEIVED <br /> MONITORING SYSTEM CERTIFICATION SEP 17 2018 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report mustMMENTAL <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to th�m <br /> owner/operator.The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 3MIciL it ii, ARTAAENT <br /> A. General Information <br /> Facility Name: PACIFIC SERVICE STATION Bldg.No.: <br /> Site Address: 6131 PACIFIC AVENUE city: STOCKTON zip: 95207 <br /> Facility Contact Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring system: VEEDER ROOT SMPLICITY Date of Testing/Servicing: 8/28/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific a ui ment inspect Iserviced: <br /> Tank ID: 87 OCT Tank Size: 12 K Tank ID: Tank Size: <br /> ® In-Tank Gauging Probe. Model: M A G I ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 3 0 3 ❑ Annular Space cr Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 3 5 2 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Seneor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> D Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: P L L D - 8 4 8 4 ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL Tank Size: 12 K Tank ID: 91 OCT Tank Size: 12 K <br /> ® In-Tank Gauging Probe. Model: M A G I ® In-Tank Gauging Probe. Model: M A G I <br /> ® Annular Space or Vault Sensor. Model: 3 0 2 ® Annular Space or Ve ult Sensor. Model: 3 0 3 <br /> ® Piping Sump/Trench Sensor(s). Model: 3 5 2 ® Piping Sump/Trench Sensor(s). Model: 3 5 2. <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: P L L D - 8 4 8 4 ® Electronic Line Leak Detector. Model: P LLD- 8 4 8 4 <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: 3 / 4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chants). <br /> Dispenser ID: 5 / 6 Dispenser ID: 7 / 8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensogs). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Flcet(s)and Chain(s). ® Dispenser Containment Floats)and Cham(s). <br /> DispenserlD: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chairi ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report,(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0112 <br /> Testing Company Address: 416 2n°STREET GALT,CA 95632 Data of Testing/Servicing: 8/28/2018 <br /> Monitoring System Certification Pagel of4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.