CSOVED <br /> F. In-Tank Gauging/SIR Equipment: N Check this box if tank gauging is used only for inventorl 117 2018 <br /> El Check this box if no tank gauging or SIR equipment is inS�/tt11d�A d. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: ENVIRONMENTAL <br /> wii ILA -Qn T FNT <br /> ❑ Yes ❑ No` Has all input wiring been inspected for proper entry and tennination,including testing for ground faults? <br /> ❑ Yes ❑ No' Were all tank gauging probes visually inspected for damage and residue buildup? <br /> ❑ Yes ❑ No' Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ No' Was accuracy of system water level readings tested? <br /> ❑ Yes ❑ No' Were all probes reinstalled properly? <br /> ❑ Yes ❑ No' Were all items on the equipment manufacturers maintenance checklist completed? <br /> 'In Section H,below,describe how and when these deficiencies were or will be corrected. <br /> Line Leak Detectors(LLD): ❑ Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> N Yes ❑ No' For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) <br /> ❑ N/A Simulated leak rate: N 3 g.p.h.; ❑0.1 g.p.h; ❑0.2 g.p.h. <br /> N Yes ❑ Na' Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> N Yes ❑ No' Was the testing apparatus properly calibrated? <br /> ❑ Yes ❑ No' For mechanical LLDs,does the LLD restrict product flow If it detects a leak? <br /> N N/A <br /> N Yes ❑ No` For electronic LLDs,does the turbine automatically shut off If the LLD detects a leak? <br /> ❑ N/A <br /> N Yes ❑ No' For electronic LLDs,does the turbine automatically shut off If any portion of the monitoring system is disabled or disconnected? <br /> ❑ N/A <br /> N Yes ❑ No' For electronic LLDs,does the turbine automatically shutoff if any portion of the monitoring system malfunctions orfails a test? <br /> ❑ N/A <br /> N Yes ❑ No' For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> ❑ N/A <br /> N Yes ❑ No* Were all items on the equipment manufacturers maintenance checklist completed? <br /> In Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: ELECTRONIC LINE LEAK DETECTORS <br /> Monitoring System Certification Page 3 of 4 2/21/07 <br />