My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6131
>
2300 - Underground Storage Tank Program
>
PR0231223
>
COMPLIANCE INFO_2011 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2019 11:53:49 AM
Creation date
12/16/2019 11:27:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2018
RECORD_ID
PR0231223
PE
2361
FACILITY_ID
FA0002324
FACILITY_NAME
Pacific Service Station
STREET_NUMBER
6131
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746418
CURRENT_STATUS
01
SITE_LOCATION
6131 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page_of <br /> S-WR,1B,ipnuav-y 2002 <br /> TESMG <br /> ,7. UNDER-DilspENSER CONTAPMENT XTDC' <br /> Industry Standard X Professional Engineer <br /> vejoped%': UDC Manuf=ur,-r <br /> Other(Spec6) <br /> ED Vacuum X Hydrostatic <br /> Test Method Used: C Pressure <br /> Other(Specify) <br /> Test Equip-n,,ent used.; Caldwell Level Change Indicator Equipment Resolution: .002 <br /> UD,C# n 3&4 UDC 5&6 UDC#78 8 <br /> Manufacturer: Bravo I Bravo Bravo <br /> UDC Man Coated Steel Coated teei Coated Steel I Coated Steel <br /> UDC Material: ___L1 1. <br /> 101, 1 1011 <br /> UDC Depth: See Comments See Comments See Comments <br /> Height fromBottom to Top See Comments <br /> of Highest Piping?enetration: <br /> Height frorn UDC Bottom to Se..Comments See Cor rummne. See Comments See Comments <br /> Lowest E I ectricai.Penetration: Dry <br /> 011*71 "priorto Dry Dry Dry <br /> Condition DC <br /> testin <br /> Portion of-UDC Tested 7 'Eater level 8 __rWater Level 8:: Water Level 8" Water Level 8" <br /> -4 <br /> Does turbine shut down when No No No <br /> UDC sensor detects liquid(both No <br /> product and water)?' <br /> Turbine shutdown respo time N/A N/A N/A <br /> r yes <br /> Is system for fail- Yes 'Yes Yes <br /> safe shutdown?' <br /> Was fail-safe verified to be NO <br /> No <br /> 11 eratioral?, <br /> 1 5 Minutes 5 Minutes <br /> -lutes 5 Minutes <br /> Wait time between app!ying 5 . <br /> water and staqi a. test <br /> q Test Star,Time: 9:10 9:05 8:53 9:15 <br /> ___TV�-A <br /> ,-,�W1 0 i Me b <br /> ait time a jp .�Tn_ <br /> �9 <br /> 7 <br /> .001 .001 9:45 <br /> - <br /> Test <br /> �j�Initial 1 �35 i 9:25 <br /> End Tn:_�': 9-.40 <br /> 00 00 1 <br /> .00, 1 .001 <br /> rFinal Reading(RT,): .001 30 Minutes `0'MitlutTS5 <br /> 30 Minutes 30 Minutes <br /> .Test Duration: 0 - 0 <br /> n Readin�gPR_F-R 0 0 <br /> Changei .005/30 Minutes <br /> 'dorCrijeqn .005/30 Minutes .005/30 Minutes <br /> Pass/Fail Threshold or Criteria: .005i 0 Minutes <br /> %; <br /> Pass Pao <br /> Was sensor ren-,oved Lo��,__ Yes Yes Yes Yes <br /> Was sensor properly replaced and Yes <br /> Yes Yes I Yes <br /> verified fLnctional after testing') <br /> Comments-(i;telude i ormation oa repairs made Ardor zo testing, and recommended follow-up f <br /> grfailed-as <br /> All Penetration enter form bottom of Bravo System UDCS. <br /> AUG 2 5_2014 <br /> NTAL HEALTH <br /> DE kRTMENT <br /> If the en- dre dep,h of the UDC is not tested,specify how much was tested. If the ans-war to 4ay of the questi ons indicated with an; <br /> e. <br /> asterisk(*)is,"N'O"or'INA",the entire UDC must be tested. (See SWRCE LG-160) <br />