Laserfiche WebLink
' Quality Control Results <br /> Client: Earth Tech, Inc. Job Number: 720-14844-1 <br /> ' Lab Control Spike/ Method: 8270C <br /> Lab Control Spike Duplicate Recovery Report-Batch: 720-37157 Preparation: 3550B <br /> LCS Lab Sample ID:LCS 720-37157/2-A Analysis Batch: 720-37270 Instrument ID: Sat 2K1 <br /> Client Matrix: Solid Prep Batch: 720-37157 Lab File ID: d:\data\200806\062408\lcs <br /> Dilution: 1.0 Units: mg/Kg Initial Weight/Volume: 30.01 g <br /> ' Date Analyzed: 06/24/2008 1725 Final Weight/Volume: 1 mL <br /> Date Prepared: 06/23/2008 1506 Injection Volume: 1.0 uL <br /> ' LCSD Lab Sample ID:LCSD 720-37157/3-A Analysis Batch: 720-37270 Instrument ID: Sat 2K1 <br /> Client Matrix: Solid Prep Batch: 720-37157 Lab File ID: d:\data\200806\062408\lcsd <br /> Dilution: 1.0 Units: mg/Kg Initial Weight/Volume: 30.05 g <br /> ' Date Analyzed: 06/24/2008 1759 Final Weight/Volume: 1 mL <br /> Date Prepared: 06/23/2008 1506 Injection Volume: 1.0 uL <br /> ' % Rec. <br /> Analyte LCS LCSD Limit RPD RPD Limit LCS Qual LCSD Qual <br /> Dibenz(a,h)anthracene 93 102 58-108 9� 35 <br /> Surrogate LCS% Rec _ LCSD%Rec Acceptance Limits <br /> Nitrobenzene-d5 _ 73 73 21 -98 <br /> 2-Fluorobiphenyl 76 77 38-96 <br /> Terphenyl-d14 70 69 32-117 <br /> 2-Fluorophenol 60 60 28-98 <br /> Phenol-d5 69 73 23-101 <br /> 2,4,6-Tribromophenol 83 72 37-114 <br /> t <br /> Calculations are performed before rounding to avoid round-off errors in calculated results. <br /> TestAmerica San Francisco Page 22 of 30 <br />