My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3505
>
2300 - Underground Storage Tank Program
>
PR0231848
>
COMPLIANCE INFO_2006 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:33:46 PM
Creation date
1/10/2020 1:36:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2018
RECORD_ID
PR0231848
PE
2361
FACILITY_ID
FA0002052
FACILITY_NAME
NuStar Terminals Operations Partnership L.P.
STREET_NUMBER
3505
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16203004
CURRENT_STATUS
01
SITE_LOCATION
3505 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL/15/2009/WED 12:25 PM NuStar Energy STKN FAX No, 2099430653 P, 003/006 <br /> 07/13/2009 10:69 FA-1 109 744 0116 0004/0006 <br /> 0. Results of TesUngfServlcing <br /> software Version Installed. 99 <br /> :om lete,thofallowin ctieCldlst <br /> Yes 0 No' Is the audible alarm operational? <br /> ® Yes p No, Is the visual alarm operetional? <br /> p Yes ® Na' Were all sansors vlsualty Inspected,Nricdmally tested,and conftrmed operational'? <br /> El Yes ❑ No' Were all senso a installed at Icwee pant of secondary W uiainment and positioned so that other egrdpmert we rot interfere with their proper <br /> Operiaton? <br /> ❑ Yes ❑ No, if alarms are relayed to a remote monRorfng station,Is all communications equipment(e.g.,modem)operational? <br /> P9 WA <br /> ❑ Yes 0 No' For preasur9ted plping systems,does the turbine automadmily shut down if the piping secondary containment monitoring system deiecte a <br /> IM NtA leak, fags to operate, or Is eler^rtcafly dlsearcxKted? if yes:wtuh sensate initiate positive shutdown? (Check all flet apply) Q <br /> Sump/bench Sensors; C1 Dispenser Containment Sensors. <br /> Old you eonffrm positive shutdown due to leaks end senwr feilureldiacormaction? ❑Yes; ❑No. <br /> n Yee D No' For tank systema that utilize the monitoring system as the primary tank overfill warning device(.e„no mechanical overfll prevention valva is <br /> I] N/A Installed), Is the overfill yarning alarm vsibla and audibly at the tank fill point(s)and operating properly? It so,at what percent of tank <br /> otwity does the&lawn trfggsr? 80'/, <br /> L) Yes* 0 No Was any monkoring equipment replaced? It yea,idOrtdfy specific sensors.probes,or other egapment replsoed and flat the mahufacturer <br /> name and model for all replacement parts In Section E,below- <br /> r] Yes' ® No Was ilquld found Inside arty secondary containment sWtsms desiyrtad as dry systems? (Chack all that apply) <br /> ❑Product, D Water- If yes,descrba causes in Section E,Wow, <br /> ® Yes I ❑ No, W,a monitodng system set-up reviawed to ensure proper settings?Attach setup reports,if applicable <br /> Q Yes 1 9 No' Is a6 monitoring eWfprnAnt oparatlonal par mwrifaclure,0s apecifiration5? <br /> in section a below,describe how and when these deficlaocies were or will be corrected. <br /> E. common w- INSPEGTOR RAY SJV ON SITE <br /> TESTED!-ILS SENSOR AND FLOAT WAS MISSING OR FELL,OFF. SITE CONTACTED ELITE 4 TO REPAIR <br /> AND PULL PERMIT.ELITE WILL.REPAIR AND RETEST ASAP ,PER KERRY AT ELITE 4 <br /> Monitoring System Cortifioation Page 2 oto 2121107 <br /> i.: <br /> tt <br /> _t <br /> iF': <br />
The URL can be used to link to this page
Your browser does not support the video tag.