Laserfiche WebLink
TABLE I <br /> REMEDIATION PILOT TEST <br /> OPERATIONAL UPTIME SUMMARY AND FLOW <br /> Barnes Trucking, 1817 South Fresno Avenue, Stockton, California <br /> Applied Influent Air Influent Air Dilution Dilution Dilution Air PID <br /> Date & Time o Hour Meter Vac Area Inf Temp Velocity Flowrate Area Air Temp Av Flowrate <br /> z Reading Velocity S s Inf Eff <br /> T P Hg It2 F fpm acfm F fprn acfin my my <br /> 12/3/13 8:30 11791 .7 20 0.0491 72 1 ;800 88.4 0.0218 0 41 12 <br /> 12/3/ 13 9:30 1 ,792.7 20 0.0491 74 11800 88 .4 0.0218 0 45 4.5 <br /> 12/4/13 6:00 10 11814.6 20 0.0491 65 2,000 98.2 0 .0218 62 2.9 <br /> 12/6/13 4:45 15838 .4 <br /> 12/9/13 7:30 11 17840.6 23 0.0491 80 15700 83 .4 0.0218 55 1 .6 <br /> 12/10/13 6:00 1 ,859.9 17 0.0491 60 1 ,800 88.4 0.0218 75 1 .3 <br /> 12/11 /13 7:30 1 ,885. 1 17 0.0491 70 15800 88.4 0.0218 - <br /> 12/12/13 6:00 1 ,907.4 17 0.0491 65 19900 93 .3 0 .0218 - 211 1 .8 <br /> 12/13/13 6 :00 12 - - - <br /> 12/16/13 11 :40 13 2,008.9 18 0.0491 92 15800 88 .4 0.0218 93 1 .2 <br /> 5-day Test 22 I 101 1 1 ,992 1 98 1 80 1 ,916 42 93 2 <br /> Average <br /> 30-day test 19 72 1 ,779 87 59 758 23 95 5 <br /> Ue end / Ke : Sample Calculation : <br /> Vac = Vacuum fpm = feet per minute air flow = area of pipe (0.0491 ft') x air velocity (fpm) = flowrate (acfm) <br /> "Hg = inches mercury acfm = actual cubic feet per minute <br /> ft2 = square feet ppmv = parts per million by volume <br /> Temp = temperature PID = Photoionintion Detector <br /> F = Fahrenheit Sys Inf= System Influent (includes dilution air) <br /> Inf = Influent Eff= Effluent <br /> - :,net applicable/ not measured <br /> Notes: <br /> Influent pipe diameter - 3.0 inches <br /> 1 System operating with DPE, extracting from well MW- 10 only. <br /> System operating with DPE, extracting from well MW-513 only. <br /> 3 System operating with DPE, extracting from wells IW-6, IW-77 IW-8 and MW-5E. <br /> System operating with DPE, extracting from wells IW-7 and IW-8. <br /> 5 System operating with DPE, extracting from well IW-8 only. <br /> T?Bamea Tmeatna�aeaiaeednstsames oxm oPs test tables Page 3. of 4 STRATUS <br />