Laserfiche WebLink
ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Unit Supervisors -- <br /> m Donna K,Heran,RX.H.S. 304 East Weber Avenue, Third F100Z Carl Borgman,R.E.H.S. <br /> Director Mike Huggins,R E.H.S.,R.D.I. <br /> Al Olsen,R.F.H.s. Stockton, California 95202-2708 Douglas W.Wilson,R.E.H.S. <br /> c'y;� .N�c• Program Manager Telephone: (209) 468-3420 Margaret Lamio,R.E.H.S. <br /> Laurie A.Cotulla,R.E.H.S. Robert McClellon,R.E.H.S. <br /> Program Manager - Fax: (209) 464-0138 Mark Bareellos,R.E.H.S. <br /> Nov 0 3 2004 <br /> D CHARLES SKOBRAK <br /> 9947 FAST HIGHWAY 26 <br /> STOCKTON CA 95215 - <br /> RE: Larry's Auto SITE CODE 1122 <br /> 308 North Grant Street: RO: 194 <br /> Stockton, CA 95202 <br /> San Joaquin County Environmental Health Department (EHD)has reviewed Work Plan <br /> Addendum—October 2004 dated October 20,2004, and prepared by Advanced <br /> GeoEnvironmental, Inc. (AGE) for the above-referenced site. 'his work plan addresses the <br /> advancement of six-paired cone penetrometer testing (CPT) borings to depths of 225 feet <br /> below ground surface (bgs) to investigate soil lithology and hydrogeoiogic units, and to <br /> define the vertical and lateral extent of impacted groundwater. CPT-1 is to be advanced at <br /> the former underground storage tank location at northwest comer of this site, and CPT- <br /> 7 is to be advanced approximately eight feet west of monitoring well MW-7 at the south <br /> end of this site; CPT-4 is to be advanced at the southwest corner of 331 North Aurora <br /> Street; CPT-5 is to be advanced at the northwest comer of 825 East Miner Avenue; CPT-6 <br /> is to be advanced at the southern edge of 835 East Miner Avenue; and CPT-8 is to be <br /> advanced on the west side of Grant Street opposite monitorng well MW-3. <br /> Although many of the CPT boring locations differ from what EHD proposed during a <br /> meeting with AGE on June 12, 2003,EHD approves the work plan as submitted. EHD also <br /> recommends that an additional CPT-paired boring (CPT-9)be advanced to a total depth of <br /> 225 feet bgs at the southern boundary of 806 East Lindsey Street. EHD believes this <br /> newly-proposed boring would complete the investigation to the north for the above- <br /> referenced site. Please submit access agreements for each parcel,the City of Stockton <br /> encroachment permit,boring permit applications for each parcel, and permit fees of$89.00 <br /> per parcel,to EHD by December 6, 2004. Fieldwork must be completed by December 17, <br /> 2004 and the report of finding must be submitted within eight weeks of completing the <br /> fieldwork. <br /> EHD directs you to collect grab groundwater samples from each distinct, saturated <br /> permeable zone during the advancement of the paired borings. Although the work plan <br /> proposes to analyze groundwater samples by Environmental Protection Agency(EPA) SW- <br /> 846 Method 8260B and report the entire suite of analytes,EHD recommends that you <br /> report only compounds that have historically shown positive results. These include <br /> benzene, toluene, ethyl benzene,total xylenes,di-isopropyl ether(DIPE),methyl tertiary- <br /> butyl ether(MTBE),tertiary butyl alcohol (TBA), 1,2-dichloroethane(1,2-DCA), 1,2- <br /> dibromoethane(EDB),n-butyl benzene, sec-butyl benzene, tert-butyl benzene, carbon <br /> disulfide,chloroform, chloromethane, p-isopropyitoluene,methyl ethyl ketone, <br />