Laserfiche WebLink
15 November 2019 AdvancedGeo <br /> AGE Project No. 19-4912 Environmental <br /> Page 4 of 14 <br /> ADDRESS: 573 East Galin Road <br /> LOCATION: Adjacent property to south <br /> SEPTIC SYSTEM: 1) Permit date November 1962; new installation of septic system: 800- <br /> gallon tank with two compartments, distribution box (D-Box), and two 75-foot long leach <br /> lines; 2) Permit date October 1994; repair/addition: add one 40-foot long leach line and <br /> one sump 14 feet deep; 3) Permit date June 2002; repair/addition: destroy 800-gallon <br /> tank, replace with 1,200 gallon tank and add three 80-foot long leach lines. <br /> ADDRESS: 591 East Galin Road <br /> LOCATION: Approximately 25 feet to southeast <br /> SEPTIC SYSTEM: 1) Permit date July 1964; new installation of septic system: 800-gallon <br /> tank with two compartments, distribution box (D-Box), and two 75-foot long leach lines; <br /> 2) Permit date June 2000; destroy septic tank; 3) Permit date December 2001; new <br /> installation of septic system: 1,200-gallon tank with two compartments, distribution box <br /> (D-Box); 4) Permit date March 2005; replacement: replace existing tank with 1,600-gallon <br /> tank with two compartments. <br /> ADDRESS: 609 East Galin Road <br /> LOCATION: Approximately 75 feet to southeast <br /> SEPTIC SYSTEM: 1) Permit date October 1957; new installation of septic system: 1,080- <br /> gallon tank with two compartments, distribution box (D-Box), and two 50-foot long leach <br /> lines; 2) Permit date May 2010; replacement: replace existing tank with 1,200-gallon tank <br /> with two compartments. <br /> ADDRESS: 10251 S Priest Road <br /> LOCATION: Approximately 75 feet to southwest <br /> SEPTIC SYSTEM: 1) Permit date May 1952; new installation of septic system: 1,030- <br /> gallon tank with two compartments, distribution box (D-Box), and one 60-foot long leach <br /> line; 2) Permit date May 1960; new installation of septic system: 800-gallon tank with two <br /> compartments, distribution box (D-Box), and two leach lines, 40 and 80 feet long, 3) <br /> Permit date February 1964; new installation of septic system: 1,200-gallon tank with two <br /> compartments, distribution box (D-Box), and two 90-foot long leach lines; 4) Permit date <br /> September 1969; new installation of septic system: 1 ,200-gallon tank with two <br /> compartments, distribution box (D-Box), and one 100-foot long leach line and one <br /> seepage pit to 5 feet. <br /> 3.6. PROPOSED MAXIMUM SEPTIC TANK USAGE ON SITE <br /> The new proposed septic system is planned to be located in the western portion of the <br /> property over 100 feet away from the proposed domestic water well. The proposed septic <br /> system will service the planned four-bedroom residential home to be developed on the <br /> property. The proposed septic system will be used by the four-bedroom residence 365 <br /> days per year. The average and reasonable maximum usage of wastewater for a four- <br /> bedroom home by residents is 140 gpd per bedroom for a total of 560 gpd. <br />