My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
13880
>
2900 - Site Mitigation Program
>
PR0508216
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2020 3:26:24 PM
Creation date
1/24/2020 3:16:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508216
PE
2960
FACILITY_ID
FA0007997
FACILITY_NAME
MANSFIELD PROPERTY
STREET_NUMBER
13880
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20927030
CURRENT_STATUS
02
SITE_LOCATION
13880 W GRANT LINE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Chpy "`!a <br /> Ch <br /> evron <br /> t rF dT SI,yI�� <br /> September 14, 1998 Chevron Pipe Line Company <br /> 4000 Executive Parkway,Suite 400 <br /> San Ramon,CA 94583 <br /> P.O:Box 6059 <br /> Mr. Michael J. Infurna, Jr. San Ramon,CA 94583-0759 <br /> San Joaquin County Public Health Services <br /> Environmental Health Division <br /> P. O. Box 388 t <br /> Stockton, CA 95201-0388 I� <br /> 44 <br /> Work Plan for Field Investigation 4 <br /> Mansfield Property <br /> 13880 W. Grant Line Road, Tracy,CA 95376 I <br /> Dear Michael: <br /> I <br /> Enclosed please find a completed Master File Record Information form (i.e.,,Green Form andpi '-a"'. <br /> check for$234.00 for the purpose of opening a San Joaquin County Public Health Services— <br /> Environmental <br /> ervices—Environmental Health Division(PHS-EHD) account for the subject property. The'purpose for <br /> opening an account with PHS-EHD is that Chevron Pipe Line Company (CPL) proposes to <br /> advance one soil boring, B-1, in the approximate location shown on the attached Figure 1 to <br /> ascertain if CPL's historical pipeline operations in the area have adversely impacted site soil and <br /> groundwater in the subsurface at the location of the proposed boring. <br /> i <br /> If no evidence of petroleum impacted soil is observed in the soil core collected from the boring, <br /> one soil sample will be collected at a depth of approximately 5 feet below ground surface, and no <br /> grab groundwater sample will be collected. The soil sample will be analyzed for benzene, <br /> toluene, ethylbenzene, and total xylenes (BTEX)using U.S. Environmental Protection Agency <br /> (EPA) Method 8020, polyaromatic hydrocarbons (PAHs)using EPA Method 8270 SIM, and <br /> total petroleum hydrocarbons (TPH)using EPA Method 8015M quantified against a crude oil <br /> standard (C8 to C36 carbon range). , <br /> If petroleum impacted soil is observed, then CPL proposes to implement the Technical.Approach j <br /> to Site Evaluation and Decision-Making, Old Valley Pipeline Sites—Central Valley (March 20, <br /> 1997; "Consistent Approach"). The number of soil borings required to define the vertical and <br /> lateral extent of the affected soil will be agreed to between CPL and PHS-EHD's representatives <br /> in the field; at least three additional borings will likely be required. Similarly,the location and <br /> ter samples to be collected to ascertain impact to groundwater will be <br /> number of roan <br /> dwa <br /> numb g p <br /> agreed to between CPL and PHS-EHD representatives in the field. The soil and groundwater <br /> samples will be analyzed for the following constituents as described below: <br /> j • The soil samples will be analyzed for BTEX using EPA Method 8020, PAHs using EPA <br /> Method 8270.SIM, and TPH using EPA Method 8015M quantified against a crude oil <br /> standard (C8 to C36 carbon range). <br />
The URL can be used to link to this page
Your browser does not support the video tag.