Laserfiche WebLink
January 30, 1998 FLUOR DANIEL GTI <br /> Mr. Bob DeNinno <br /> ti.. The Southland Corporation <br /> 555 S. Renton Village Place, Suite 700 <br /> Renton,WA 98055 <br /> Subject: Fourth Quarter 1997 Monitoring and Sampling Report <br /> Southland Site No.20304 <br /> +� 455 Grant Line Road <br /> Tracy,California <br /> Fluor Daniel GTI Project 02070 0456 <br /> Dear Mr. DeNinno: <br /> This Fourth Quarter 1997 Monitoring and Sampling Report presents the results of monitoring and sampling <br /> �. activities performed by Fluor Daniel GTI, Inc. (Fluor Daniel GTI) at the subject site(Figures 1 and 2, <br /> Attachment 1) on November 11, 1997. Activities conducted during this reporting period are summarized <br /> below. <br /> ■ Depth to water(DTW)was gauged in 11 groundwater monitoring wells and three <br /> groundwater extraction wells(Figure 2). <br /> V <br /> ■ Groundwater samples were collected from five wells:MW-4,MW-5, MW-8,MW-9,and <br /> MWA 0,and submitted to a certified laboratory for analysis for benzene,toluene, <br /> ethylbenzene and xylenes(BTEX),total petroleum hydrocarbons-as-gasoline(TPH-G), <br /> and the oxygenates, methyl-tert-butyl-ether(MTBE),tert-butanol (TBA),diisopropyl ether <br /> (DIPS), ethyl-tert-butyl ether(ETBE), and tent-amylmethyl ether(TAME). <br /> LW <br /> Groundwater Monitoring Data <br /> Groundwater monitoring was performed on November 11, 1997. Prior to monitoring,the well caps were <br /> opened to allow the water level in each well to stabilize to atmospheric pressure. The DTW was measured <br /> to the nearest 0.01 foot from the top of the well casing using an ORS Environmental Equipment <br /> INTERFACE PROBE Well Monitoring System. <br /> Separate-phase (SP) hydrocarbons were not detected in any of the monitoring wells. The water table <br /> elevations, calculated from the November 11, 1997 monitoring data,were used to prepare a potentiometric <br /> surface map(Figure 2). The groundwater flow is generally toward the north at a hydraulic gradient of 0.002 <br /> ,r to 0.004 fttft. Groundwater monitoring results from the November 11, 1997 monitoring and sampling event <br /> are presented in Table 1,and historical results are summarized in Table 1A(Attachment 2). Field data <br /> sheets are included in Attachment 3. <br /> Monitoring Well Sampling and Analytical Results <br /> +-R Groundwater samples were collected from wells MW-4, MW-5,MW-8,MW-9,and MW-10. Before <br /> sampling, at least four well-casing volumes of groundwater was removed from each monitoring well, unless <br /> 757 Arnold Drive, Suite D / Martinez, CA 94553 USA (510) 370-3990 FAX (510) 370-3991 <br /> L,! <br />