Laserfiche WebLink
CAMBRIA <br /> service station is located to the south, and an active Valero service station is located to the <br /> southwest of the subject site. <br /> The 7-Eleven site is an active environmental case overseen by the SJCEHD. 'SECOR issued a <br /> t <br /> site investigation report for the 7-Eleven site on September 30, 2004. SECOR reported that <br /> methyl tertiary butyl ether (MTBE) from the 7-Eleven site has migrated to the north and <br /> northwest,beneath the Shell site. <br /> Previous investigations . <br /> k <br /> January 2003 Well Installation: As part of Shell's voluntary Groundwater Assessment Program <br /> (GRASP), KHM.installed four groundwater monitoring wells (MW-1 through MW4) at the <br /> subject site during January 2003. Groundwater samples collected from these wells contained <br /> MTBE at concentrations ranging;from 0.69 to 730 parts per billion (ppb). After discovery of <br /> MTBE in groundwater beneath this site, Shell submitted an Unauthorized Release Report on <br /> March 25,2003. <br /> t� November 2004 Dispenser Replacements: Cambria collected native soil samples from beneath 401 <br /> the former dispensers at depths of approximately 5 to 8 feet below grade(fbg). Total petroleum <br /> hydrocarbons as gasoline (TPHg) was detected in two soil samples at concentrations of 1.9 and <br /> 340 parts per million (ppm). Benzene was detected in two soil samples at concentrations of 0.6I <br /> and 0.011 ppm. Total petroleum hydrocarbons as diesel(TPHd)was detected in two soil samples <br /> at concentrations of.11 and 33 ppm. MTBE was detected in six soil samples at concentrations <br /> ranging from 0.018 to 0.44 ppm. Tertiary butyl alcohol (TBA) was detected in five soil samples <br /> at concentrations ranging . from 0.011 to 0.020 ppm. No other fuel. oxygenates, <br /> i 1,2-dichloroethane, or ethylene dibromide were detected in soil samples collected from beneath <br /> the dispensers. These activities were documented in Cambria' January 20, 2005 Dispenser <br /> Upgrade Sampling Report. <br /> November 2004 Sensitive Receptor Survey: Cambria performed a sensitive receptor survey in <br /> the vicinity of the subject site. In the Sensitive Receptor Survey Report and Site Investigation <br /> Work Plan submitted November .18, 2004, Cambria identified two domestic water wells <br /> approximately 1 300 feet southwest and 1900 feet east of the site. These wells area approximately <br /> PP Y � � PP Y <br /> JL 220 and 180 feet deep and screened from 195-220 and 157-177 fbg,respectively. <br /> i <br /> Included in the November 18, 2004 report was the results of a well survey performed by SECOR <br />{ for the 7-Eleven site. Five private wells'were identified by SECOR on Corral Hollow Road <br /> t <br /> 1661 2 <br /> r: <br />