Laserfiche WebLink
12. AST Spill Prevention Equipment Product is remote filled via connecting caddies to Dumps via a quick <br /> connect hose. Product is not normally handled outside of intended containers Tank is an integral <br /> secondary containment tank. <br /> 13. Overfill Protection Tank has continuous electronic monitoring with a BJ Ent TM1 audible alarm was <br /> tested & determined to be in good working condition Additionally,system has a TM1 solenoid auto shut <br /> down when product levels in tank reach 90% Pumps have manual ball valve shut off, accessible to operator. <br /> 14. Toxic Considerations Antifreeze is toxic to humans and animals. Waste antifreeze contains heavv metals <br /> such as lead cadmium and chromium in high enou h levels to Potentially make it a re ulated hazardous <br /> waste,so most states strictly regulate antifreeze disposal Antifreeze generators and state and local programs <br /> should not dump spent antifreeze on land or discharge it into a sanitary sewer,storm drain,ditch, dry well,or <br /> septic system; dumDing antifreeze can cause serious water quality problems and might harm people pets or <br /> wildlife. <br /> 15. AST secondary containment(material/design/listed) AST has integral secondary containment via double <br /> wall construction to completely capture anv leaks from primary vessel InteQrai secondary containment was <br /> tested,is intact and AST is suitable for continued usage <br /> 16. Damage to AST or systems None reported. Upon inspection no evidence of seam breaks, punctures <br /> cracks, or other structural damage to the tank Leak detection is assured via inspections of the secondary <br /> containment and the surrounding area. Poly wall thickness tested to 6 5mm average <br /> 17. Comments <br /> a. Dimensions of AST: Primary Vessel=250 gallons capacity max <br /> Dimensions: 48 in. Ht. X 41in. Diam /3in crown top ( 18 in opening for product removal.) <br /> b. Product stored: used (waste) Coolant: Specific Gravity = 1.03 <br /> c. ( )emergency ent per fire-code) <br /> PE certification <br /> 1 certify under penalty of Imv that this document and all attachments were prepared under my direction or supervision in <br /> accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. <br /> Based on my inquiry of the person or persons who manage the system, or those persons direct/)'responsible for gathering the <br /> information, the information submitted is, to be the best of my knowledge and belief, true, accurate, and complete. I ant mt,are <br /> that there are significant Pel7alliesfor submitting false ittfornratiarn, including the possibility of fine and imprisonment for• <br /> knowing violations. <br /> I have reviewed the data and confirm it complies XX /dees not-Eemply with CCR section 66265.192(k) <br /> oQRpfESS/OH9l Neal P Hay <br /> P Printed Name of Registered PE <br /> y <br /> No. 55634 <br /> W/ <br /> * * Signature ofRegi d�PE­7 <br /> C/O- �\Q Expires 12-31-2018 <br /> (seal) lF OF CNO�'`l <br /> Date October 5, 2018 Registration Number C55634 State CA <br />