Spill Prevention Compliance Corporation <br /> Periodic Integrity Test Certificate <br /> P.O. Box 1289........Waterford, CA 95386 Telephone: (209) 969-0851 <br /> Email: spccorp(y)hotmail.com <br /> ----------------------------------------------------------------------------------------------------------------------------- <br /> Client: Tracy Ford New Cars Contact : Wayne Maciel, Service Manager <br /> Address: 3500 Auto Plaza Way Phone No.: 209-835-4821 <br /> City/State/Zip; Tracy, CA 95304 Date of Test: 8-23-18 <br /> Product Stored: Waste Coolant-a <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Unknown/250 aals/Waste Coolant/Dble Wall Poly IS09000-40CFR-264193 compliant/15 Yrs old(estimate) <br /> Description of Secondary Containment Integral Secondary Containment <br /> Date of Test 8-23-18 Test Supervisor(s) Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX SecondaryXX <br /> 1. Poly Outer Wall Thickness Test(in accordance with ISO 9000/9014 and/or STI SP001 (6th edition)- <br /> readings avg. 6.5 mm thickness- Suitable for continued usage <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogen CO2: Other(specify) <br /> Air Pressure-Test Vacuum Test ; <br /> Initial Reading(document psi/WC readings) Time <br /> End Readings (document psi/WC readings) Time <br /> Duration of Test: %drop <br /> 3. Sonar-Test_Y_N (document db readings) Duration <br /> 4. Camera(visual) /interstitial (Result: P/F)_ <br /> 5. Hydro-Carbon Sensor(probe) model (Result: P/F) <br /> 6. Hydrology (Water Column) ( inches of water column readings) <br /> Duration % Drop Results (P/F) <br /> 7. Other: Inspect Primary Vessel & Secondary containment. CRDM present, no evidence of leaking <br /> product from primary vessel, system accessible for inspection: AST sits within secured Service Area <br /> room. No evidence of seam breaks,punctures cracks or other structural damage to the tank. Leak detection <br /> is assured via inspections of the secondary containment& surrounding area No evidence of leak nor of any <br /> product in secondary. Tank has continuous electronic levels monitor/alarm: PASS <br /> TEST RESULTS <br /> 1st-Stage: <br /> Pass XX Fail_(quantify) OUTER WALL THICKNESS= 6.5 mm ON SIDE AVG. SUITABLE <br /> FOR CONTINUED USAGE <br /> 2" -Stage: <br /> Pass XX Fail_(quantify) NO VISUAL EVIDENCE OF PRODUCT IN INTERSTICE OR ANY <br /> OTHER LEAKS <br /> Comments Tank has been anchored to wall. data on file <br /> Date of Next Scheduled Periodic Integrity Test 8-23-23 <br /> SPC Corp Representative <br /> STI SP00] Certified Inspector No.: AST 135013 <br />