My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002834
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARBOR
>
1805
>
2900 - Site Mitigation Program
>
PR0508461
>
ARCHIVED REPORTS_XR0002834
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 5:28:32 PM
Creation date
1/29/2020 3:41:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002834
RECORD_ID
PR0508461
PE
2950
FACILITY_ID
FA0008092
FACILITY_NAME
CONTINENTAL GRAIN CO
STREET_NUMBER
1805
STREET_NAME
HARBOR
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14502005
CURRENT_STATUS
01
SITE_LOCATION
1805 HARBOR ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tri Regional Recommendation Page 5 of 24 <br /> Appendix A <br /> • Completing a Quality Assurance/Quality Quality Assurance/Quality Control plan in- <br /> Control plan including chain-of-custody eluding chain-of-custody procedures for <br /> procedures for field sampling and analysis field sampling and analysis <br /> Specific to the groundwater investigation,the 3 2 Preliminary Investigation and Evaluation Re- <br /> workplan is to include the following port (PIER) - X2654, X2723 <br /> • A proposal to complete a sensitive receptor The soil and groundwater data collected from im- <br /> survey to show water supply wells and sur- plementing the Site Investigation Workplan is to be <br /> face water bodies within 2,000 feet of the presented in the PIER and used to create the Site <br /> site With field observation and venfication Conceptual Model Information developed for this <br /> of any wells within 500 feet of the leaking report will be used to determine what additional <br /> underground storage tank site and attempt- work is needed at the site The PIER is to contain <br /> ing to obtain depth of annular seal for those <br /> wells Summarized background information devel- <br /> oped from the Site Investigation Workplan <br /> • A rationale for installing monitoring wells and results of the completed sensitive recep- <br /> including well location, total depths, screen for survey <br /> intervals, and annular seal depth <br /> The area of investigation is to be accurately <br /> • A construction diagram for any proposed delineated on maps and cross sections to <br /> monitoring wells including the well diame- scale to depict the lateral and vertical extent <br /> ter, casing and screen type,annular sealing of impacted soil and groundwater identified <br /> method and depth to date <br /> • The drilling method to be implemented and Cross sections must include stratigraphy <br /> decontamination procedures used between based upon boreholes, trenches, monitoring <br /> borings wells,or any other supporting information, <br /> and must show analytical results and con- <br /> The method of well development, and the struction details for all monitoring wells to <br /> criteria for selecting the proposed method demonstrate the degree of impact to ground- <br /> water and site soils <br /> Disposal plans for soil and purge water <br /> Tables summarizing analytical data and <br /> Plans for completing a location survey of the methodologies used to collect and analyze <br /> installed monitoring wells the samples <br /> Free product measurement method • Depth to groundwater, and calculated <br /> groundwater elevation <br /> Water level measurement procedure <br /> • Groundwater quality contoured on a site <br /> Well purging procedure map for each groundwater unit investigated <br /> Sample collection procedures • A graphical and narrative site conceptual <br /> model(SCM) showing the extent of known <br /> Analytical methods to be used and appropn- soil contamination and groundwater degra- <br /> ate detection limits (Analytical laboratories dation relative to the leaking UST system <br /> are to report all peaks identified from the and potential receptors The SCM should be <br /> soil and groundwater testing, and provide updated as characterization data becomes <br /> chromatograms as necessary) available, and used to make determinations <br /> for future investigations <br />
The URL can be used to link to this page
Your browser does not support the video tag.