Laserfiche WebLink
s'*4 American Environmentar Network <br /> WORK ORDER 9802221 QUALITY CONTROL REPORT PAGE QR-5 <br /> ANALYSIS Volatile GUMS <br /> MATRIX. Water <br /> METHOD BLANK SAMPLES <br /> - . .. - - - ---- --- - --- - ------ ----------- ------------- - -- - - -- - - - ------- ------ ----- - - - <br /> SAMPLE TYPE Blank Method/Media blank LAB ID BLNK 0226 INSTR RUN GCMS121980226000000/8/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12WO22698 <br /> UNITS ug/L ANALYZED 02/27/98 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REG LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> trans-1 4-Dichloro-2 buten ND 100 <br /> cis-1,3Dichloropropene ND 5 <br /> trans I,3 Dichloropropene ND 5 <br /> 2-Hexanone ND 50 <br /> Methyl Iodide NO 200 <br /> 4 Methyl-2 pentanone NO 50 <br /> Vinyl Acetate ND 50 <br /> 2-Chloroethyl Vinyl Ether ND 10 <br /> MTBE ND 5 <br /> LABORATORY CONTROL SAMPLES <br /> ------ - -- ------- - -- - --- --- - ----- ------ ---- -- - - -- - -- ------- --- ----- -- - ------ ------------ -- - <br /> SAMPLE TYPE Laboratory Control Spike LAB ID LCS 0226 INSTR RUN GCMS121980226000000/2/1 <br /> INSTRUMENT HP mass spec for Volatiles PREPARED — BATCH ID MS12W022698 <br /> UNITS ug/L ANALYZED 02/26/98 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> • 1 2 DCA d4 (surr) 112 106 100 112 65 135 <br /> Toluene-d8 (surr) 101 99 6 100 101 70 130 <br /> pBFB (surr) 100 99 5 100 100 70 130 <br /> 1,1-Dichloroethene 63 4 NO 5 50 0 127 70 130 <br /> Benzene 48 7 NO 5 50 0 97 4 70 130 <br /> Trichloroethene 44 5 NO 5 50 0 89 0 70 130 <br /> Toluene 51 4 NO 5 50 0 103 70 130 <br /> Chlorobenzene 52 6 NO 5 50 0 105 70 130 <br /> ----- - ------ - ----- -- ------------- -- -- ---- - --- - - - -- -- - -- ---- ---------- - ----------- ---------- - - <br /> -- - - ---- - - ----- -- ---- -- -- -- -- - ---- - - --- --- -- -- -- - ----- ---- ----- - --------- --- -- ---- - - <br /> SAMPLE TYPE Laboratory Control Spike LAB ID LCS 0226 INSTR RUN GCMS121980226000000/9/8 <br /> INSTRUMENT HP mass spec for Volatiles PREPARED — BATCH ID MS12WO22698 <br /> UNITS ug/L ANALYZED 02/27/98 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCA d4 (surr) 112 106 100 112 65 135 <br /> Toluene dB (surr) 101 99 6 100 101 70 130 <br /> p BFB (surr) 100 99 5 100 100 70 130 <br /> 1 1 Dichloroethene 63 4 NO 5 50 0 127 70 130 <br /> Benzene 48 7 NO 5 50 0 97 4 70 130 <br /> Trichloroethene 44 5 NO 5 50 0 89 0 70 130 <br /> Toluene 51 4 NO 5 50 0 103 70 130 <br /> Chlorobenzene 52 6 ND 5 50 0 105 70 130 <br /> - End of Quality Control Report ---- --- <br />